H7c82f9e798154899b6bc46decf88f25eO
H9d9045b0ce4646d188c00edb75c42b9ek

AM cheap and Advanced ventilator equipment AMVM12

Short Description:

Product Name:Advanced ventilator equipment AMVM12 for sale
Latest Price: US$300-1028/Set

Model No.:AMVM12
Weight:Net weight:62 Kg
Minimum Order Quantity:1 Set Set/Sets
Supply Ability:300 Sets per Year
Payment Terms:T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal


Product Detail

Product Tags

Quick Details

AMVM12 ventilator is a gas-driven, electrically controlled and multi-functional mechanism, which incorporates time and capacity switches and pressure restrictions.

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

Advanced ventilator equipment AMVM12 for sale

ventilator price | ventilator machine price

Advanced ventilator equipment AMVM12 Main Characteristics

AMVM12 ventilator is a gas-driven, electrically controlled and multi-functional mechanism, which incorporates time and capacity switches and pressure restrictions. The main purposes of ventilator are to:  provide the patients who are in a deadly danger with respiratory support at their most dangerous stage;  protect patients in going through their dangerous period; ensure a successful basic treatment for further recovery; provide substitutes for anti-reversion respiratory muscle pathological changes or anti-reversion upper windpipe injury to maintain the patients’ breathing function; provide breathing support for patients after sickness or during the recovery period after operation.     Main characteristics are stated as follows: a.Gas-driven, electrical control, time-pressure switch, and pressure limit control b.Have air-oxygen mixer particles of high-performance, can adjust the oxygen concentration conveniently and accurately. c.Apply electronic PEEP, can make continuous adjustment of PEEP.  d.PTR has 2 kinds of trigger ways: Pressure trigger and flow trigger.  e. Apply highly and fast sensitive pressure sensor and flow sensor to airway pressure, gas flow detection, control and display, and has ventilation auto-compensation  f. Many ventilator modes: VCV, PCV. PSV, SIMV. PSIMV(SIMV+PSV), CPAP. g. Apply led, real-time displays these parameters, such as controlling frequency, tidal volume, ventilation, total breathing frequency, self respiratory rate, compliance, airway resistance, oxygen concentration, it also displays pressure and curve of flow vale to time. h. P-V (Pressure-Volume), F-V (Flow-Volume). i. When the ventilator runs abnormally or is incorrectly operated, it will trigger both audio and visual alarms to protect itself. j. even if the power is off, no chokes will occur to the patients, for the respiration tubes are connected to the outer atmosphere.  

AM Advanced ventilator equipment AMVM12 for sale Work Environment

Normal working conditions of PA-900B II: _____Temperature: 10~40℃ _____Relative Humidity: ≤80%  _____Atmospheric Pressure: 86 kPa ~ 106 kPa _____Gas: medical oxygen and compressed air of 280~ 600kPa _____Power: AC220V±10%, 50±1Hz, 40VA, with ground protection. ventilator price | ventilator machine price  

Cheap ventilator equipment AMVM12 for sale Structure and work principle

•AMVM12 ventilator is motivated by medical oxygen and compressed air. Under inspiratory phase, two ways of compressed gases (compressed oxygen and air) enter air-oxygen commingler, forming a gas mixtureof certain pressure that mixes medical oxygen, and then enter electronic controlled inspirator rates valve of high performance, last do mechanical ventilation in the patient’s respiration tract through inhale tubes of ventilator; under expiratory phase, the patients exhale gas to the atmosphere through filter, and expiration control valve of the expiration tubes. During this process, high-performance rates control valve, highly sensitive flow sensor and pressure sensor and single-chip microcomputer control system are adopted to bring airway pressure, airway flow speed closed-loop regulation, thus realize Gas-driven, electrical control, time-pressure switch, and pressure limit control NOTICE:This unit could work properly under the condition of medical oxygen and compressed air combining together. Meanwhile, the pressure for the common gas should be the around 0.4MPa.   The ventilator will do real-time display of these following parameters: _____Work mode and I/E ratio _____ Pre-set controlling frequency  _____Tidal volume per respiration _____The appearance of spontaneous respiration and its frequency _____ Oxygen concentrator _____ Plat form pressure and Airway peak pressure _____ Compliance and airway resistance _____Real-time changes of airway internal pressure _____Display of Inspiratory status and Expiratory status, actual respiratory frequency _____Ventilation capacity per minute _____ Airway pressure, respiratory frequency, tidal volume, alarm bounds of Ventilation capacity per minute.   The ventilator triggers alarms whenever abnormal situation occurs. For example, the ventilator will trigger alarms when airway pressure is too low which may be caused by leakage or falling off. When the airway pressure is too high which may be caused by the blockage of tubes, it will not only trigger alarms automatically, but also transfer the ventilator from inspiratory status to expiratory status to release the over-high pressure if  the pressure keeps on rising.  

Best ventilator equipment AMVM12 for sale Technical Specification

Basic functions _____Assistant Respiration, controlling respiration, autonomous respiration _____ End-Inspiratory Halts _____ PEEP _____Sigh (deep breath) _____ Standby Work Mode _____VCV (volume control ventilation) _____PCV (Pressure Control Respiration mode) _____PSV (Pressure supporting volume) _____ IMV (Intermittent Mandatory Ventilation mode) _____SIMV (Simultaneous Intermittent Mandatory mode) _____CPAP (Continuous Positive Airway Pressure)   Basic Parameters Tidal Volume adjustment: 0-1500ml Tidal Volume: 50~1500ml, error of displayed value: 100 ml and lower than ±20 mL, others ±20 % Maximum ventilation capacity per minute: ≥18L/m,  Oxygen Concentration: 21%-100%,±15% error allowed Ventilation Conformance: ≤ 30 mL/kPa IPPV range: 0~99 times/m, ±15% error allowed. I/E Ratio: 4:1、3:1.、2:1.、1:1.、1:1.5、1:2.、1:2.5、1:3.、1:4, ±15% error allowed SIMV: 1-20 times/m, ±15% error allowed. Maximum Safety Pressure: ≤6.0kPa Control Pressure: 0.3kPa ~ 4 – PEEP  PTR sensitivity: PEEP-1 cmH2O~PEEP—9 cmH2O adjustable, ±1 cmH2O error allowed. End-inhale continuous time: 0 ~ 50% adjustable, that is 0.1s ~ 20 s. PEEP: 0.1 kPa~1.0 kPa flow trigger sensitivity: Level 3 and Level 8. Pressure Restriction: 1~6kPa, ±20 % error allowed. Sigh( deep breath): deep breath in 100 times breath, 1-8 times adjustable( after 10-100 times’ control breath, there will be 1 time deep breath),  the inspiration time is 1.5 times to the setup time. Sustained Operation: 24 hours for main power supply, no less than 30 minutes for built-in battery application only.

 

 

 

   

Relate hot sale and cheap portable anesthesia machine

AMGA07PLUS AMPA01 AMVM14
AMGA15 AMVM06 AMMN31

AM TEAM picture 

 


  • Previous:
  • Next:

  • Leave Your Message:

    Write your message here and send it to us.

    Leave Your Message:

    Write your message here and send it to us.