Quick Details
15" color TFT screen Multi-channel display Big font interface
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
Color TFT screen Multi-channel display patient monitor AMMP10
15" color TFT screen Multi-channel display Big font interface
ST and arrhythmia analysis Drug dose calculation and titration table OxyCRG dynamic view display Respiration monitoring with apnea alarms Alarm review, arrhythmia review Patient info. Input Anti-defibrillation design NIBP over pressure protection Plug-in rechargeable battery, AC/DC available. Supporting wire or wireless network. ECG Lead mode 5 Leads, I, II, III, AVR, AVL, AVF, V Gain ×2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV,auto Heart rate Measure range: Adult 15 ~ 300 bpm Neonatal/Pediatric 15 ~ 350 bpm Accuracy ±1% Resolution 1 bpm Sensitivity > 200 VμP-P Differential Input Impedance > 5 M ohm CMRR Monitor Mode >100 dB Surgery Mode >100 dB Diagnostic Mode >90 dB Electrode offset potential ±300mV Leakage Current < 10 μA PACE pulse detect range±2~±700mV width 0.1~2ms rise time 10~100 μs PACE pulse rejection range ±2 ~±700mV width 0.1~2ms rise time 10 ~100 μs Baseline Recovery < 3 s After defibrillation. Signal Range ±8 mV p-p Bandwidth Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz Calibration Signal 1 mV p-p, 5% accuracy ST measurement Range -2.0 ~+2.0 mV Accuracy-0.8mV~+0.8mV ±0.02mV or±10%, which is greater Other range: unspecified Cardiotocography, ctg machine, ctg machine price, ctg machine cost.
Cheap patient monitor AMMP10 Respiration
Method Impedance between RA-LL Differential Input Impedance >2.5 MΩ Respiration Impedance Range 0.3~3Ω Base Impedance Range 200Ω~4000Ω Bandwidth 0.1 ~ 2.5 Hz Gain ×0.25,×0.500,×1,×2,×4 Respiration Rate Measurement Range Adult 0 ~ 120 BrPM Neonatal / Pediatric 0 ~ 150 BrPM Resolution 1 BrPM Accuracy 0~6 BrPM: unspecified 7~150 BrPM:±2 BrPM or±2% use the greater Inspiriting current < 300 A RMS max Apnea Alarm 10 ~ 40 s NIBP Method Oscillometry Measure mode Manual, Auto, Continual Measure Interval in AUTO Mode 1,2,3,4,5,10,15,30,60,90,120,180,240,480 min Measure Period in Continual Mode 5 min Pulse Rate Range 40 ~ 240 bpm Measure and Alarm Range Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 220 mmHg DIA 10 ~ 150 mmHg MEAN20 ~ 165 mmHg Neonatal Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg Static pressure accuracy ±3mmHg Resolution 1mmHg Accuracy Maximum Mean error ±5mmHg Maximum Standard deviation 8mmHg Overpressure Protection Adult 297±3 mmHg Pediatric 240±3 mmHg Neonatal 147±3 mmHg SpO2 Measurement Range 0 ~ 100 % Resolution 1 % Accuracy 70% ~ 100% ±2 % 69% 0% ~ 39% unspecified Pulse Rate Measure and Alarm Range 20~300bpm Resolution 1bpm Accuracy ±3bpm TEMP Channel 2 Measure and Alarm Range 0 ~ 50℃ Resolution 0.1℃ Accuracy(no sensor) ±0.1(25℃-45℃),0.2±℃(other) Accuracy(include sensor) ±0.2℃(32℃-42℃) ±0.3(other) tandard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature Optional: EtCO2, IBP, Thermal Recorder Cardiotocography, ctg machine, ctg machine price, ctg machine cost.
AM TEAM picture
AM Certificate
AM Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods arrive destination safely and quickly.
Welcome to medicalequipment-.com,If you have any demand in Patient monitor. Please feel free to
contact cindy@medicalequipment-.com