Technical Specification
|
||
Application
|
0.5-100kg animal
|
|
Ventilation mode
|
Closed,half-closed,half-open
|
|
Tidal volume
|
10-2000ml
|
|
Oxygen source pressure
|
0.25~0.65Mpa
|
|
Airway pressure scope
|
030~60CMH2O
|
|
Flow Control
|
0-4L/min
|
|
Oxygen Flush
|
35L/min~75L/min
|
|
Pop adjust scope
|
Directs the waste anesthetic gas from the machine to a scavenging system. In the completely open position, the pop-off valve will release pressure at 2 cm H2O, while maintain a constant passive volume in the breathing bags.
|
|
Inspiration impedance
|
≦0.6Kpa
|
|
Expiration impedance
|
≦0.6Kpa
|
|
Absorption tank capacity
|
700ml
|
|
Monitoring
|
Airway pressure,Gas source pressure monitoring
|
|
I:E
|
As doctor need
|
|
BPM
|
As doctor need
|
Configuration list
|
||||
Main unit
|
1
|
Include the flowmeter,CO2 absorber,selectatec bar,chassis,oxygen flush
|
||
Anesthesia Vaporizer
|
1
|
Isoflurane,Halothane,Sevoflurane, Enflurane
With temperature, flow and pressure compensation |
||
Breathing circuit
|
1
|
|||
Gas airbag0.5L,1L,3L
|
3
|
|||
Reusable Silicon pipeline
|
1
|
Ф22×1000
|
||
Oxygen hose
|
1
|
|||
Y-connector
|
1
|
With pressure differential sampling connector
|
||
Trolley
|
1
|
|||
Regulator
|
Optional
|
|||
Anesthesia ventilator
|
Optional
|
Model:DAV80V or DAV60V
|
||
Anesthesia monitor
|
Optional
|
Anesthesia monitor
|
||
Non-Breathing circuit
|
Optional
|
|||
Veterinary Mask
|
Optional
|
DAM80
|
||
Laryngoscope
|
Optional
|
|||
Endotracheal intubation
|
Optional
|
|||
Exhaust gas recovery tank
|
Optional
|
DE0602
|
Product Features
* Compact light-weight and portable, could be transported by pull-rod case, put on table and assembly on the trolley.
* Suitable for small animals, Non-breathing circuit(Jackson or Bains Absorber)is available
* Selectatec-bar and quick change vaporizer mounting device
* Professional airtight breathing circuit design, provide the stable gas anesthesia, save anesthesia gas consumption, to ensure a clean operating room and laboratory environment.
* External and reusable soda lime canister, easily watch and replace soda lime.
* With Oxygen flush function to ensure that clinical anesthesia demand and Oxygen supply demand.
* Anaesthesia CO2 absorber assembly has no dead angle design, fast anesthesia, short recovery and high precision. The CO2 absorber supports both open loop and closed loop anaesthesia design and provides independent access .
* Provide a special Pop-Off valve,Occlusion design, it can connected to the exhaust gas recovery system and provide a continuous 2 cmH2O negative pressure for the reaspirato airbag ,reducing valve to prevent pressure to hurt the animal, ensure the animal safety .
* Provides an accurate oxygen flow meter with a display range of 0 to 4LPM
* Vaporizer: the output concentration is not affected by the change of flow, pressure and temperature, accurate and reliable,equipped with safety locking device to prevent anesthetic leakage. Isoflurane,sevoflurane and halothane vaporizer are optional.
* The hard aluminum solid shell is used, and the surface sanding treatment is adopted, so that the cleaning and disinfection are more convenient.
* Visible inspiration and expiration valve
* Specifically designed to accomodate low flow anesthesia