H7c82f9e798154899b6bc46decf88f25eO
H9d9045b0ce4646d188c00edb75c42b9ek

Amain OEM/ODM AMDA800V smart touch screen Veterinary Anesthesia respirator

Short Description:


Product Detail

Product Tags

Product Description
Amain OEM/ODM AMDA800V smart touch screen Veterinary Anesthesia respirator
Specification
Amain AMDA80V Specially user for animal,anesthesia
ventilator,could widely apply in vet hospital,animal R&D institute,university laboratory,animal clinic,animal zoo,etc,it can match
any brand anesthesia machine to use
Basic description
Parameter
Description
Display
9 inch TFT, with touch screen.
Drive gas
Gas type
O2 or Air
Inlet pressure
280-600 kPa.
Max flow
≤ 120 L / min.
Operating Mode
VCV,PCV,SPONT,Manual,Demo
Waveform
Waveform:
Pressure,Flow-rate,Volume
Loop:PV loop, PF loop,FV loop
Safety Pressure
System pressure does not exceed 6 KPa.
Battery Type
Li-ion,work time more than 2 hours
Parameters setting range
Parameter
description
Tidal volume
Range: 20 – 1500ml; Increment: 1 mL;
Respiratory rate
Range: 1 ~ 100 bpm;
Inspiratory time
Range: 0.1 ~ 10.0 s
Respiratory ratio
Range: 9.9:1 to 1:9.9
Percentage of inspiratory pause
Range: 0 to 50%
PEEP
Range: OFF, 3 ~ 20 cmH2O
Pressure Support
Range: 0 ~ 60 cmH2O
Pressure Control
Range: 5 ~ 60 cmH2O
Flow trigger
Range: 0.5 ~ 20L/min
Pressure Trigger
Range: -1 ~ -20 cmH2O
PSV Insp Termination Level
25%.
Monitored parameters
Parameter
Description
Inspiratory tidal volume
Range: 0 ~ 2500 mL
Expiratory tidal volume
Range: 0 ~ 2500 mL
Minute ventilation
Range: 0 ~ 60 L / min
Spontaneous minute ventilation
Range: 0 ~ 60 L / min
Respiratory rate
Range: 0 ~ 100 bpm
Spontaneous breathing frequency
Range: 0 ~ 100 bpm
Respiratory ratio
Range: 9.9:1 to 1:9.9
Peak airway pressure
Range: 0 ~ 100 cmH2O
Mean airway pressure
Range: 0 ~ 100 cmH2O
PEEP
Range: 0 ~ 100 cmH2O
Inspiratory plateau pressure
Range: 0 ~ 100 cmH2O
FiO2(optional)
Range: 15 to 100%
Alarm settings
Alarm type
Range
Tidal volume
High
0 ~ 2000 mL, OFF
Low
0 ~ 1500 mL
Minute ventilation
High
1 ~ 99 L
Low
0 ~ 98 L
Respiratory rate
High
1 ~ 100bpm
Low
0 ~ 99 bpm
FiO2(optional)
High
19 ~ 100%
Low
18 ~ 99%
Airway pressure
High
6 ~ 99 cmH2O
Low
0 ~ 9 8 cmH2O
FiCO2 (optional)
High
0.1 to 13.3%;
Low
0 to 13.2%
Continuous Positive Airway Pressure
Airway pressure greater than (PEEP +15) cmH2O, 15 s sustained when an alarm is triggered.
Negative pressure alarm
Airway pressure is less than (-10) cmH 2 O.
Apnea alarm
Setting time is 10 ~ 60 s, in increments of 1 s.
Gas deficiency alarm
Gas pressure is less than 280 kPa.
AC power failure alarm
The mains breaks down or the power cord disconnects
Low battery alarm
Alarm battery time is 20 min.
Alarm battery is exhausted
Alarm battery time is 10 min.
Silent Alarm
≤ 120 s
O2 sensor failure
FIO2 <15% Vol;
Product Features

* Compact and salve the space.
* Light and easy to move,save animal hospital cost.
* automatically Calculation by weight to the other parameter
* With breathing mode PCV mode, achieve the breathing automatically,
* Assure the animal more comfortable.
* With big animal bellow and small animal bellow,specially for animal use
* The gas source pipeline take the high precious gas source,no leakage forever.
* HD TFT Touch screen,perfect technology,touch at key to Set parameter ,very easy and simple to operate.
* Build in battery could continue two more hours in case of power failure