H7c82f9e798154899b6bc46decf88f25eO
H9d9045b0ce4646d188c00edb75c42b9ek

Breast Flat Panel Detector AMFP30 for sale

Short Description:

Product Name:Breast Flat Panel Detector AMFP30 for sale|Medsinglong
Latest Price:

Model No.:AMFP30
Weight:Net weight: Kg
Minimum Order Quantity:1 Set Set/Sets
Supply Ability:300 Sets per Year
Payment Terms:T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal


Product Detail

Product Tags

Quick Details

Amorphous silicon TFT/PD matrix panel
Scintillator    CsI (TI)
Pixel pitch    85µm
Effective active area    235mm x 290mm
Effective pixel matrix    > 2762 x 3408
AD conversion    16bit
Programmable gain amplifier
Energy range    25kV-40kV
AED Trigger mode Software

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

Breast Flat Panel Detector AMFP30 for sale|Medsinglong

 

1.Introduction

 

The AMFP30 is a digital FPD detector with the patented Amorphous Silicon TFT sensor and needles directly deposited CsI: Tl scintillator technique of iRay technology. It is designed with the compact outline in order to retrofit the analog mammography system to digital. AMFP30 has a quite large active area of 24x30cm with 85μm pixel pitch. The employed CsI (Cesium Iodide) scintillator makes the AMFP30 achieve a special high DQE and MTF. The detector provides AED (Auto Exposure Detection) function via the specialized sensor to detect the X-ray for activing the FPD, and is also compatible with the existed AEC function of the analog mammography system. AMFP30 supports FFDM applications.

 

  1.  General Technique Specifications

 

 

Sensor technology

Amorphous silicon TFT/PD matrix panel

Scintillator

CsI (TI), needles directly deposited on the a-Si TFT panel

Pixel pitch

85µm

Effective active area

235mm x 290mm

Effective pixel matrix

2762 x 3408

AD conversion

16bit

Charge amplifier

Programmable gain amplifier

Energy range

25kV-40kV

DataControl interface

 

GigE

Trigger mode

Software, AED

AED function

Yes

Frame rate

2fps@Free run

Cycle time

Typical 15s

 

 

  1.  Image Quality

 

 

Limited spatial resolution

6 lp/mm

Saturation dose*

Typical 2500μGy @ 7.2pC

Dynamic range*

>76dB @ 7.2pC

QNED

(measured according to European Guidelines)

 

FFDM: ≤20µGy @ Binning 1C

QNLD

(measured according to European Guidelines)

 

FFDM: ≤80µGy @ Binning 1C

Linearity*

≥ 0.999

 

MTF* @ RQM1/Binning1C

(measured according to IEC62220-1-2)

Typical 90% @ 1.0 LP/mm

Typical 70% @ 2.0 LP/mm

Typical 58% @ 3.0 LP/mm

Typical 29% @ 5.0 LP/mm

 

 

 

DQE* @ RQM1/Binning1C

(measured according to IEC62220-1-2)

Typical 69% @ 0 LP/mm

Typical 65% @ 1.0 LP/mm

Typical 56% @ 2.0 LP/mm

Typical 45% @ 3.0 LP/mm

Typical 31% @ 5.0 LP/mm

Lag

(measured according to IEC62220-1-2)

 

< 1.5% (first frame)

Memory effect

<0.3%, after 60s

 

 

(measured according to IEC62220-1-2)

 

CNR @ 45mm PMMA

≥ 12.5

Image receptor homogeneity

(measured according to European Guidelines)

 

<10%

 

ACR phantom @ clinical condition

≥ 4 fibers

≥ 4 masses

≥ 3 speck groups

Missed tissue at the chest wall side

< 3 mm

*: The Radiation quality is W/Rh (50µm), according to IEC62220-1-2:2007.

 

  1.  Mechanical

 

 

Weight

1.3kg

Housing material

Aluminum with carbon fiber laminate entrance window

Size (mm3)

327 (L) × 254.5 (W) × 14 (H)

 

 

 

Outline

 

 

 

 

  1.  Communications

 

 

Data interface

GigE

X-ray synchronization interface

AED

Software

SDK, supporting the 32 and 64 Windows® OS

 

 

 

  1.  Environmental and Reliability

 

 

Temperature

10 – 40 °C (operating), -10 – 55 °C (storage)

 

Humidity

10 – 90% RH (operating, non-condensing)

10 – 95%RH (storage)

Pressure

700 – 1060mbar (operating and storage)

Vibration

IEC 60068-2-6 (10-200 Hz, 5 g)

Shock

IEC 60068-2-29 (16ms, 10 g)

Life time

5 years

Life time dose

Typical 300Gy

IBFR

≤ 2.5%

CFR36

≤ 7.5%

 

 

 

  1.  Power

 

 

Supply

100-240V AC and mains frequency of 50Hz and 60Hz, both +/- 2%.

Input

24V DC

 

 

Dissipation

Around 18W

Cooling

Passive

 

 

 

  1.  Regulatory

 

 

General regulatory

CE, RoHs

Risk management

ISO 14971: 2007

 

 

Safety and essential perfor mance

IEC60601-1:2005/EN60601- 1:2006+AC:2010/IEC 60601-1:2005+

Amendment 1:2012/EN 60601-1:2006+

Amendment 1:2013

IEC 60601-1-2:2014

Radiation protection

IEC 60601-1-3:2008

Characteristics of digital X-ray imaging devices

IEC 62220-1-2:2007

 

 


  • Previous:
  • Next:

  • Leave Your Message:

    Write your message here and send it to us.

    Leave Your Message:

    Write your message here and send it to us.