Dali nga mga Detalye
15" color TFT screen Multi-channel display Dako nga font interface
Pagputos ug Paghatud
Detalye sa packaging:Standard export package Detalye sa pagpadala: sulod sa 7-10 ka adlaw sa trabaho human madawat ang bayad |
Mga detalye
Kolor nga TFT screen Multi-channel display pasyente monitor AMMP10
15" color TFT screen Multi-channel display Dako nga font interface
ST ug arrhythmia analysis Pagkalkula sa dosis sa tambal ug titration table OxyCRG dynamic view display Pag-monitor sa pagginhawa nga adunay mga alarma sa apnea Pagrepaso sa alarma, pagrepaso sa arrhythmia Impormasyon sa pasyente.Input Anti-defibrillation design NIBP over pressure protection Plug-in rechargeable nga baterya, AC/DC anaa.Pagsuporta sa wire o wireless network.ECG Lead mode 5 Lead, I, II, III, AVR, AVL, AVF, V Gain ×2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV,auto Heart rate Measure range: Adult 15 ~ 300 bpm Neonatal/Pediatric 15 ~ 350 bpm Katukma ±1% Resolution 1 bpm Sensitivity > 200 VμP-P Differential Input Impedance > 5 M ohm CMRR Monitor Mode >100 dB Surgery Mode >100 dB Diagnostic Mode >90 dB Electrode offset potential ±300mV Leakage Current <10 μA PACE pulse detect range±2~±700mV width 0.1~2ms rise time 10~100 μs PACE rejection range ±2 ~ ± 700mV gilapdon 0.1 ~ 2ms pagtaas sa panahon 10 ~ 100 μs Baseline Recovery < 3 s Human sa defibrillation.Sakup sa Signal ± 8 mV pp Bandwidth Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz Calibration Signal 1 mV pp, 5% accuracy ST measurement Range -2.0 ~+2.0 mV Accuracy-0.8mV~+0.8mV ±0.02mV o±10%, nga mas dako Ubang range: unspecified Cardiotocography, ctg machine, presyo sa ctg machine, gasto sa ctg machine.
Barato nga pasyente monitor AMMP10 Respiration
Pamaagi Impedance tali sa RA-LL Differential Input Impedance >2.5 MΩ Respiration Impedance Range 0.3~3Ω Base Impedance Range 200Ω~4000Ω Bandwidth 0.1 ~ 2.5 Hz Gain ×0.25,×0.500,×1,×2,×4 Respiration Range Rate ~ 120 BrPM Neonatal / Pediatric 0 ~ 150 BrPM Resolution 1 BrPM Accuracy 0~6 BrPM: wala matino 7~150 BrPM:±2 BrPM o±2% naggamit sa mas dako nga Inspiriting current <300 A RMS max nga Apnea Alarm 10 ~ 40 s NIBP Method Oscillometry Measure mode Manual, Auto, Continual Measure Interval sa AUTO Mode 1,2,3,4,5,10,15,30,60,90,120,180,240,480 min Measure Period sa Continual Mode 5 min Pulse Rate Range 40 ~ 240 bpm Measure and Alarm Range Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 220 mmHg DIA 10 ~ 150 mmHg MEAN20 ~ 165 mmHg MEAN20 ~ 165 mmHg DIA 10 ~ 150 mmHg MEAN20 ~ 165 mmHg mmHg MEAN 20 ~ 110 mmHg Static pressure accuracy ±3mmHg Resolution 1mmHg Accuracy Maximum Mean error ±5mmHg Maximum Standard deviation 8mmHg Overpressure Protection Hamtong 297±3 mmHg Pediatric 240±3 mmHg Neonatal Rentang 147 ± 3 mmHg Neonatal 147% SpO2 ± 0.n 1 % Katukma 70% ~ 100% ±2 % 69% 0% ~ 39% wala matino nga Pulse Rate Measure ug Alarm Range 20~300bpm Resolution 1bpm Accuracy ±3bpm TEMP Channel 2 Sukdanan ug Alarm Range 0 ~ 50 ℃ Res. walay sensor) ± 0.1(25 ℃ -45 ℃), 0.2 ± ℃ (uban pa) Katukma (lakip ang sensor) ± 0.2 ℃ (32 ℃-42 ℃) ± 0.3 (ubang) tandard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Opsyonal nga Temperatura: EtCO2, IBP, Thermal Recorder Cardiotocography, ctg machine, ctg machine nga presyo, ctg machine cost. AM TEAM nga hulagway Sertipiko sa AM Ang AM Medical nakigtambayayong sa DHL, FEDEX, UPS, EMS, TNT, etc.International shipping company, himoa nga luwas ug dali nga makaabot ang imong mga butang sa destinasyon. Malipayon nga pag-abut sa medicalequipment-msl.com, Kung adunay bisan unsang panginahanglan sa monitor sa Pasyente.Palihug mobati nga gawasnon sa kontakcindy@medicalequipment-msl.com