Quick Details
Overall performance
Equipment type Fully automatic, discrete, STAT priorty
Analysis rate Colorimetry speed 240T/H (single/double reagent)
Test principle Colorimetry, turbidimetry
Analysis method End-point, kinetics, fixed-time, etc.Support single/double wavelength and 1-2 multiple reagent item.linear and non-inear calibration
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
Overall performance
Equipment type Fully automatic, discrete, STAT priorty
Analysis rate Colorimetry speed 240T/H (single/double reagent)
Test principle Colorimetry, turbidimetry
Analysis method End-point, kinetics, fixed-time, etc.Support single/double wavelength and 1-2 multiple reagent item.linear and non-inear calibration
Sample reagent unit
Sample reagent position The reagent and sample share one disk, totally 67 positions
Continuously cooling at all positions to keep 5-15c within 24 hours
Sample cuvettes specification Standard cup, original blood tube, multi-specification tube available
(φ12-16)mmx(25-100)mm
Sample volume 3p35μ0. ul stepping
Reagent volume R1: 10ul-350ul, R2: 10ul-200ul, 1ul stepping
Sample reagent probe 1, with the function of liquid level detection and collision detection
Sample reagent prote caming rate Automatic warm water cleaning. Carrying rate so.1%
Automatc sample dilution 3-115
Reaction unit
Reaction cuvette 120 positions optical plastic cup, optical diameter is 6 mm
Total volume cf readion iquid 150ul-550ul
Reaction temperature 37℃,±0.1℃
Reaction disk constant temperature Circulating water
Mixer 1, after joining reagent, blending immediately
Reaction cuvette deaning 8 stops 12 steps by warm water rinsing
Wastewater treatment With the function of concentrated waste liquid level alarming
Optical system
ight source 20W/12V halogen lamps
Monochromator Grating photometry
Photoelectron road After spectrophotometry
Wavelengths 340nm,380nm,405nm,450ntm,480m,505m,546m,570nm,
600nm, 660nm, 700nm, 750nm or 800nm
Detector Photodiode LED array
OD linear range 0-3.3Abs
Calibration and QC
Calibration method 1 point linear method, 2 point linear method, multiple point linear
method. non-linear method
Calibration tracking Automatic description calibration k-value trends
QC method Real-time QC, individual QC and monthly QC
Out of control processing Alarming for out of control sample, record lost control reason
Operating system
PC operating system Windows XP
Analysis control software Graphical operating software english version
Main function of software Automatic calibration, automatic barcode scanning, item compounding
test, reagent info management, serum index, whole reaction process
monitoring, dirty cup memory evading, prevent cross-contamination
procedure, patient information memory and association input, automatic
report audit, data multiple parameter query, report format statistic and
printing, reference range classification, alarming information
classification, user operating right classification, automatic dormancy
and wake, real-time online help
Report printing Report formats support the user-defined mode, QC and state information etc
PC configuration CPU 222GHZ(dual-core processor): Memory 21G: Harddisk 2 160G17 inch LCD display, Stylus, inkjet or laser printer(optional)
System connection TCP/P network connection, standard rs-232cers
Volume 998mmx752mmx517mm
Weight 120kg
Power supply Voltage AC 220V+22V, 50/60HZ, power 650VA