Model No.:AMRX02
Weight:Net weight: Kg
Minimum Order Quantity:1 Set Set/Sets
Supply Ability:300 Sets per Year
Payment Terms:T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal


Product Detail

Product Tags

Quick Details

Perfect environmental adaption makes it available for indoor and vehicle application for different intended use. User-friendly GUI(Graphic user interface),support various exposure mode User-friendly Interface, simple and easy to operate Fast transmission speed, comply with DICOM3.0 protocol, can achieve the seamless link with HIS. RIS. and PACS systems. Powerful tools for patient management, data gathering and image reconstruction, viewing and measuring, typesetting, printing, storage, provides rich aides for diagnosis With special detector of a-Si for breast mammography, X-ray is transferred to electric signals directly without the additional process of transferring x-Ray to visible and then to electric signal.This eliminates the artifact due to scattering of X-Ray and guarantees the authenticity from the imaging mechanism and can really satisfy the requirements of breast mammography on details. With high DOE, this can guarantee high resolution of image and meanwhile decrease irradiation dose.

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

Efficient Navigator DR Mammography AMRX02

Perfect environmental adaption makes it available for indoor and vehicle application for different intended use. User-friendly GUI(Graphic user interface),support various exposure mode User-friendly Interface, simple and easy to operate Fast transmission speed, comply with DICOM3.0 protocol, can achieve the seamless link with HIS. RIS. and PACS systems. Powerful tools for patient management, data gathering and image reconstruction, viewing and measuring, typesetting, printing, storage, provides rich aides for diagnosis With special detector of a-Si for breast mammography, X-ray is transferred to electric signals directly without the additional process of transferring x-Ray to visible and then to electric signal.This eliminates the artifact due to scattering of X-Ray and guarantees the authenticity from the imaging mechanism and can really satisfy the requirements of breast mammography on details. With high DOE, this can guarantee high resolution of image and meanwhile decrease irradiation dose.

Efficient Navigator DR Mammography AMRX02

Item

Description

1

Mammography System

Rating power:5000VA

Integrated System (Generator Integrated within the main device)

High voltage generator output: ≥100 kHz, 20 kV to 40 kV increment step: 1 kV

High performance X-ray tube:

Standard:Molybdenum Anode, Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large)

Optional:Tungsten Anode, Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large)

Support isocenter rotation function

C-arm Rotation range: +180°~ -135°

Height range of breast support surface: 735mm-1315mm;

C-arm power-driven electrically, Dual side digital display;

Compression plate: flexible and multi-level smart Compression

Spatial Resolution: >6 Lp/mm

Detector type: Amorphous Silicon Detector

Effective Imaging Area: 24*30cm

Acquisition Station compatible with DICOM 3.0

Focal distance : 650mm

Added filter: Mo / Rh

Added filter Switch: Manual/Automatic

X-ray Field adjustment: Manual

Magnification factor: 1.5

Exposure mode: Manual / AEC

Supply: 220V~,±10%

Frequency: 50/60Hz±1Hz

Max. power : 5000 VA

N.W.: 240 Kg

Compact design, minimum device height: < 1.1 m

Packing Size: 121 X 94 X 145 CM

2

High-Voltage Generator

a)  Frequency:≥100KHz;

b)  Tube voltage Range: 20 kV ~ 40 kV in 1 kV step;

c)  Max Output: 4 kW;

d)  Max tube voltage:40kV;

e)  Max tube current: 140mA;

f)  Max current time product: ≥630mAs;

g)  Ripple: <4%.

 

3

X-Ray Tube

Standard:

Imported X-ray tube for Mammography;

Anode Type: Molybdenum;

Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large)

Permanent filtration: 0.5mmBe

Max anode speed: 10000rpm/min;

Max tube voltage:40kV;

Max tube current: 35mA(small)/140mA(Large)

Anode heating capacity: 300 kHu

Optional:

Imported X-ray tube for Mammography;

Anode Type: Tungsten;

Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large)

Permanent filtration:0.5mmBe;

Max anode speed: 10000rpm/min;

Max tube voltage:49kV;

Max tube current: 35mA(small)/140mA(Large)

Anode heating capacity: 300 kHu

4

Beam Limiting Device

Electric switch between Molybdenum or Tungsten added filter;

Adjustable X-ray field manually.

Light field indicator is on automatically as compression plate moves down;

Light field indicator is off with delay as compression plate stops moving;

e)  Off delay of light field indicator can be set via software.

5

C-arm Assembly

C-arm up-down and rotation movement controlled via C-arm control panel;

C-arm stops automatically at common mammographic position: CC, OBL and LAT;

Rotation angle of OBL position can be set via software;

Support table up-down range: 735mm(L)~1315mm(H);

Rotation type of C-arm: isocenter rotation around the examined part;

Rotation range of C-arm: -135o~180o

Distance between focal spot and image reception area:650mm;

Magnification factor:1.5

Device can be installed in the movable physical vehicle as max height of device is less than 110cm;

Local display panel on the both side of the stand can indicate rotation angle of C-arm;

For safer operation, emergency stop button is locate on the top of C-arm;

Duplex foot switch(2 pcs) provided.

6 Compression Device

Up-down movement : power-driven electrically;

Compression control: continuous activation by foot;

Compression mode: flexible and multi-level compression, automatic and manual decompression;

Compression plate travel range: 5~268mm;

Compression force: 0~200N

Compression thickness: 5~268mm

Size of compression plate: 24X30cm.

7

Local Operation and Display

a) Dual display with backlight on the both side;

b) Parameters displayed:

-  rotation angle of C-arm;

-  compression thickness;

-  compression force;

-  KV;

-  mAs;

-  density

-  focal spot selected;

-  exposure mode;

-  Added filter selected;

-  automatic decompression indication;

-  state indication;

-  failure alarming indication;

c) Control function:

-  KV;

-  mAs;

-  density

-  selection of focal spot;

-  selection of filter;

-  selection of mammographic mode;

-  selection of automatic decompression    after exposure.

8

Anti-scatter Grid

Support movable grid;

Grid ratio: 5:1;

Grid density: 41 L/cm;

Grid focal distance:65cm;

Manually unload grid in magnification mode.

9 Digital Image Detector

Detector type: Amorphous Silicon Detector;

Material: Amorphous Silicon + CSI;

Min. pixel: 85µm;

Image Matrix Sizes: 2816×3528 pixels;

Effective Imaging Area: 24cm×30cm;

Image Reading Duration: <1.4s;

Interval Duration: <30s;

Spatial Resolution: 6 lp/mm;

MTF: 50%;

DQE: 65% (1 Lp/mm);

Output Gray scale: 14 bits

10 Acquisition Station

Intel CPU frequency≥2.4GHz,≥ 4 GB Memory, ≥500 GB HDD

LCD Display

Image Acquisition Software

Image Detector Self-check and adjustment

Patient Information and Image Management

Auto Explore Control

Acquisition of Explored Image Information

Browsing and Searching of Image

Measure the Distance, Angle, Space of Image and Mark The Selected Area

Image Process after Acquisition: Black and white reverse, rotate and flip, zoom, local editing, enhancement, filtering noise, copies, abridged, etc.

DICOM 3.0 Services (Print, Store, Query/Retrieve, CDRW, Scheduled Workflow and Patient Information Reconciliation)

Automatic failure diagnosis, error code and message indication;

Exposure activation: exposure button;

Data backup and recovery.

11

Automatic Exposure Control

Automatically select imaging parameters according to the thickness of breast and density of tissue;

Integration detector;

Automatically position selection.

d)  Automatically kV, filter and mAs selection.

12

Manuals

User Manual

Pre-Installation Manual

Item

Description

1

High resolution medical image display

Display Hardware: 5MP LCD Display at 2K x 2.5K

Efficient Navigator DR Mammography AMRX02

Power Capacity 5000VA
Voltage 220V~,±10%
Frequency 50/60Hz±1Hz
Earth resistance ≤0.6Ω

Item

Temperature

Humidity

Atmosphere Pressure

Shield Room

15℃~35℃

30%~60%

(No dewing)

700hPa~1060hPa

Operator Room

10℃~40℃

20%~80%

(No dewing)

AM TEAM picture 

AM Certificate

AM Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods​ arrive destination safely and quickly.


  • Previous:
  • Next:

  • Leave Your Message:

    Write your message here and send it to us.

    Leave Your Message:

    Write your message here and send it to us.