Cikakken Bayani
Ya dace da manya, likitan yara da marasa lafiya na jarirai
Marufi & Bayarwa
Cikakken bayanin marufi: daidaitaccen fakitin fitarwa Bayanin isarwa: a cikin kwanakin aiki 7-10 bayan an karɓi biyan kuɗi |
Ƙayyadaddun bayanai
arha Mahimman Alamun Kulawa don siyarwa AMV90A
Mahimman Alamun Kulawa don siyarwa fasali AMV90A
• Ya dace da balagagge, yara da marasa lafiya na jarirai • Ƙwaƙwalwar ƙwaƙwalwar ajiya, adana har zuwa sa'o'i 100 na tabular na haƙuri SpO2 • Babban haske mai sanyi cathode fluorescent backlight LCD + LED nuni • Babban fasahar sarrafa dijital da ke ba da ma'auni daidai lokacin ƙananan perfusion da yanayin motsi. Ƙararrawa masu daidaita sauti da na gani • Ginawa babban ƙarfin baturi mai cajin lithium
Mai Rahusa Alamu Mai Rahusa don siyarwa AMV90A Ƙimar Ayyuka
Girma da nauyi- Girman: 285mm * 230mm * 100mm - Nauyin: 1.7kg (ban da kayan haɗi) Ƙarfin wutar lantarki: AC100 ~240V, 50/60HZ Nuni- LED + Baturi LCD (Pluggable) - Nau'in: Batir mai caji 3.7V. 2200mAH- Cajin Cycle: ≥500 sau- Lokacin aiki: 8 hours don ci gaba da aiki Ƙararrawa- Level: Low, matsakaici da high- Nuni: Auditory da na gani Ayyukan Muhalli- Zazzabi: 5 ~ 40 ℃- Humidity: 15% ~ 80% (ba- condensing - Matsin yanayi: 86 KPa ~ 110 KPaTransportation da Adana Muhalli- Zazzabi: -20~50 ℃- Danshi: 10%~90% (ba condensing) - Matsin yanayi: 86 KPa ~ 110 KPa Sabuwar Alamun Mahimmanci don siyarwa Amintaccen AMV90A-IEC60601-1 An Amince, Alamar CE bisa ga MDD93/42/EEC- Tare da la'akari da Jagoran RoHS 2011/65/EU recastingTrend & Review- Trend: 100 hoursNIBP- Hanyar: Oscillometric- Yanayin auna: Manual, Auto, MATSAYI Auna Tazarar a Yanayin AUTO: 1,2,3,4,5,10,15,30,60,90,120,180,240 min- STAT yanayin zagayowar lokaci: Ajiye mintuna 5, aTsakanin daƙiƙa 5- Ma'auni da Ƙararrawar Ƙararrawa: Babba: SYS: 30 ~ 270 mmHg DIA: 10 ~ 220 mmHg MEAN: 20 ~ 235 mmHg Pediatric: SYS: 40 ~ 235 mmHgDIA: 10 ~ 220 mmHg MEAN: 2 mmH ~ 5 S. : 30 ~ 135 mmHgDIA: 10 ~ 110 mmHg MEAN: 20 ~ 125 mmHg- Daidaitaccen matsa lamba: ± 3mmHg- Ƙaddamarwa: 1mmHg- Daidaitawa: Matsakaicin Ma'anar Kuskuren ± 5mmHg Matsakaicin Matsakaicin Tsare-tsare ≤8mmHg Kariya ta software &- Dubi Kariya hardware SpO2 (Digital Technic) - Ma'auni Range: 0 ~ 100 % - Resolution: 1 % - Daidaitacce: ± 2% (70% ~ 100%) ± 3 % (35% ~ 69%) Ba a bayyana (0 ~ 34%) Pulse Rate- Ma'auni da Ƙararrawa: 0 ~ 250bpm- Daidaitacce: ± 1% ko ± 1 bpm, duk wanda ya fi girma - Resolution: 1bpmNellcor-SpO2 (Zaɓi) - Ma'auni Range: 0 ~ 100 % - Resolution: 1 % - Daidaita: 70 % ~ 100%, ± 2 % (babba) 70% ~ 100%, ± 3 % (Neonate) 70% ~ 100%, ± 2 % (Ƙaramar Perfusion) 0% ~ 69%, Rate Pulse da ba a bayyana ba - kewayon ma'auni: 20 ~ 300 bpm- Ƙaddamarwa: 1bpm- Accuracy: ± 3 bpm (20 ~ 250 bpm) Ba a bayyana ba (251 ~ 300 bpm)
Hoton AM TEAM
AM Certificate
AM Medical ta yi aiki tare da DHL, FEDEX, UPS, EMS, TNT, da sauransu.Kamfanin jigilar kayayyaki na duniya, sa kayanku su isa wurinsu lafiya da sauri.
Barka da zuwa medicalequipment-msl.com, Idan kuna da kowace buƙata a cikin Mahimman Alamun Kulawa.Don Allah a ji daɗin tuntuɓarcindy@medicalequipment-msl.com.