High Quality Infant Radiant Warmer - Hospital Neonatal Jaundice Infant Phototherapy Unit with Low Price – Amain Detail:
Product Description
Hospital Neonatal Jaundice Infant Phototherapy Unit with Low Price
01. LED lamp as phototherapy radiating elements.
02. Irradiance intensity is adjustable in 3 grades: low, middle, high.
03. LCD screen display therapy time and integral time separately.
04. Equal light distribution, high intensity.
05. Quiet, no noise of fan.
06. Count up timer and count down timer for exact and convenient treatment.
07. The angle of head and height are adjustable.
08. Four castors with brake, magal and steel support base.
09. Long life span LED bulbs.
10. Using together with infant incubator, infant warmer, baby cradle.
02. Irradiance intensity is adjustable in 3 grades: low, middle, high.
03. LCD screen display therapy time and integral time separately.
04. Equal light distribution, high intensity.
05. Quiet, no noise of fan.
06. Count up timer and count down timer for exact and convenient treatment.
07. The angle of head and height are adjustable.
08. Four castors with brake, magal and steel support base.
09. Long life span LED bulbs.
10. Using together with infant incubator, infant warmer, baby cradle.
Specification
Performance
|
||||||||
Power supply
|
AC110/220V, 60/50Hz
|
|||||||
Power input
|
40VA
|
|||||||
Radiant Wavelength
|
420~490nm
|
|||||||
Height adjustable range
|
850~1640mm
|
|||||||
Pitching angle of phototherapy head
|
0~180°
|
|||||||
Radiant head size
|
380*220mm
|
|||||||
Life span of LED bulbs
|
at least 20000 hours
|
|||||||
Blue LED bulbs
|
17pcs
|
|||||||
Time accuracy
|
1min/12h
|
|||||||
Integral time range
|
0~9999.9h
|
|||||||
Count down timer
|
0~8h 30min
|
|||||||
Total irradiance for bilirubin
|
||||||||
Effective surface area
|
500*360mm at 360mm
|
|||||||
High
|
2800μW/cm2
|
|||||||
Middle
|
2000μW/cm2
|
|||||||
Low
|
800μW/cm2
|
|||||||
Operating condition
|
||||||||
Temperature
|
18~30°C
|
|||||||
Relative humidity
|
10~85%RH
|
|||||||
Atmospheric pressure
|
700~1060hpa
|
|||||||
Transport and storage condition
|
||||||||
Ambient temperature
|
-10 ~ +55°C
|
|||||||
Relative humidity
|
≤95%
|
|||||||
Atmospheric pressure
|
500~1060hpa
|
Product detail pictures:
Related Product Guide:
It adheres on the tenet "Honest, industrious, enterprising, innovative" to acquire new solutions continuously. It regards prospects, success as its personal success. Let us build prosperous future hand in hand forHigh Quality Infant Radiant Warmer - Hospital Neonatal Jaundice Infant Phototherapy Unit with Low Price – Amain, The product will supply to all over the world, such as: Norwegian, Norway, Luxembourg, Our company has already have pass the ISO standard and we're fully respect our customer 's patents and copyrights. If the customer provides their own designs, We will guarantee that they will likely be the only one can have that merchandise. We hoping that with our good products can bring our customers a great fortune.
By Kay from Sri Lanka - 2018.07.26 16:51
This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.
By Catherine from Bangladesh - 2017.04.08 14:55
Leave Your Message:
Write your message here and send it to us.