Quick Details
Efficient , becuse of me
The optimal system combination of fll-automatic sampling system, pre-warming system, ten-channel multi-law test system, cuvette loading system, manipulator cuvette gripping system, washing systems and bar code recognition system greatly improves the eficiency of work.
Perfect, because of me
It has detection function of routine four blood coagulation items, special items associated with coagulation factors e.g. D-dimer and FDP; therefore, it provides a comprehensive set of diagnostic data for clinic. The instrument can be connected to Lis system for easy data management.
Accurate, because of me
Magnetic beads test completely avoids the interference of abnormal turbidity of jaundice and chyle sample, ensuring the consistency and accuracy of test results, as well as eliminating the detection errors and medical risks.
Reliable , because of me
TIt Kit with refrigeration function and sampling system with constant temperature heating and liquid surface induction extend the use time of reagent to avoid waste and ensure the accuracy of the test results.
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
Efficient , becuse of me
The optimal system combination of fll-automatic sampling system, pre-warming system, ten-channel multi-law test system, cuvette loading system, manipulator cuvette gripping system, washing systems and bar code recognition system greatly improves the eficiency of work.
Perfect, because of me
It has detection function of routine four blood coagulation items, special items associated with coagulation factors e.g. D-dimer and FDP; therefore, it provides a comprehensive set of diagnostic data for clinic. The instrument can be connected to Lis system for easy data management.
Accurate, because of me
Magnetic beads test completely avoids the interference of abnormal turbidity of jaundice and chyle sample, ensuring the consistency and accuracy of test results, as well as eliminating the detection errors and medical risks.
Reliable , because of me
TIt Kit with refrigeration function and sampling system with constant temperature heating and liquid surface induction extend the use time of reagent to avoid waste and ensure the accuracy of the test results.
AMFBA04 full-automatic blood coagulation analyzer is the innovation achievement of AMthrough five years development and research, which introduced international advanced technology, combined with the domestic clinical test requirements, and has been validated in tens of thousands of clinical tests. It detects different blood coagulation items accurately with magnetic beads and optical method. The instrument has reached international advanced level in testing speed and control function in comparison with similar products and has obtained European Union CE certification.
Parameters:
Test Method: magnetic beads method, immune turbidimetric method, chromogenic substrate method
Test Item: APTT, TT, PT, FIB and blood coagulation factors, coagulation-related special items e.g. D-dimer and FDP, AT3, PS, PC
Test Speed: 180Ts/h
Test Site: 10
Sample Site: 35
Reagent Site:21
Pre-heating Site:10
Probe: 2
Washing Site: 1
Sheathed Manipulator: 1
Automatic and manual dual-mode test capability
Insufficient cuvette and reagent alarm function
Tilt reagent position(extend the use time of reagent to avoid waste and ensure the accuracy of the test results)
Reagent position with refrigeration function
Sampling probe with liquid surface induction and constant heating function
Display coagulation curve of dynamic test
PT-derived FIB function
Automatic or manual calibration function
LED work lighting function
Batch test and emergency priority insertion test function
Abnormal test results alarm and automatic retest function
Insufficient test results alarm and waste liquid overflow alarm function
Bar code recognition function(optional)
Sheathed manipulator definitely avoids the risk of cuvette to be fallen off in the transposition process through gripping
Four directions ventilation and cooling function, makes it reliable operation
Infinite storage for test and quality control data
Cuvette loading capacity: 1000 cups
Any sample position has the funtion of emergency priority inserting
Drawer-style loading system
Immediate scanning transmission, then enter patient information soon
Waste container, reduces pollution
Full-auto Coagulation Analyzer AMFBA04
Test Speed(Ts/h) * 200
Probe 2
Sheathed Manipulators * 1
Test Method Coagulation(magnetic beads, optical), Immunoturbidimetry,chromogenic substrate
Test Items PT,APTT,FIB,TT,Factors,D–dimer,FDP, ATIII
Test Channels * 10
Sample Position 35
Pre-heating Channels 10
Till Reagents(Refrigeration) * 21
Sampling Arm * 1
Washing Position 1
Cuvettes Loading System drawer style
Reagent Loading System drawer style
Sample Loading System drawer style
Cuvettes Loading 1000
Manipulator Auto Positioning yes
Integrated Sampling Pump System yes
Inner Card Reading Function yes
Bar Code Recognition Function yes
LED Lighting * yes
Four Direction Cooling * yes
Insufficient Alarm for Cuvettes, Reagents, Detergent yes
LIS System yes