Cov ntsiab lus ceev
Fais fab tso zis 3.5KW
Zaus 40KHz
X-ray Tube Tsau anode
Ua kom pom tseeb 0.6 / 1.5mm
Tube Voltage 40-110KV (ib ntus 1KV)
Tube tam sim no 70mA
Fais fab mov 220V / 50Hz lossis 110V / 60Hz inner-resistance≤0.5Ω
Txoj Kev Ua Haujlwm Hlau / Wireless tswj
Ntim & Xa
Ntim nthuav dav: Txheem export pob Tus me nyuam nthuav dav: hauv 7-10 hnub ua haujlwm tom qab tau txais cov nyiaj them poob haujlwm |
Specifications
Nta ntawm High Frequency Mobile X-ray Imaging System AMPX11:
Zoo nkauj tsos, thiab yooj yim txav thiab khiav lag luam
Lub piller tuaj yeem tig sab xis thiab sab laug ± 90 °, uas tuaj yeem yooj yim rau kev khiav lag luam hauv pawg ntseeg.
Peb suav nrog qhov tseeb compact high-frequency thiab high-voltage X-ray generator, uas ua kom cov duab zoo dua qub, thaum cov tawv nqaij noj tsawg, los tiv thaiv tus neeg mob zoo dua.
Txais siv thev naus laus zis ntawm kV thiab mAs cov lej kaw lub voj voog tswj, Real-time tswj ntawm lub microprocessor, uas ua kom qhov tseeb thiab rov ua dua ntawm cov zis tawm.
Qhov parameter tuaj yeem hloov kho los ntawm KV thiab mAs ob lub khawm.High brightness, xiav npo LCD zaub.Nrog ntau yam kev ruaj ntseg tiv thaiv kev ua haujlwm xws li dhau-voltage, dhau-tam sim no.
Nrog rau qhov zoo tshaj plaws knockdown X-ray generator kom txo irradiation, uas muaj kev nyab xeeb ntau dua rau ib puag ncig thiab tus neeg teb xov tooj.
Specification ntawm High Frequency Mobile X-ray Imaging System AMPX11:
Fais fab tso zis 3.5KW
Zaus 40KHz
X-ray Tube Tsau anode
Ua kom pom tseeb 0.6 / 1.5mm
Tube Voltage 40-110KV (ib ntus 1KV)
Tube tam sim no 70mA
Fais fab mov 220V / 50Hz lossis 110V / 60Hz inner-resistance≤0.5Ω
Txoj Kev Ua Haujlwm Hlau / Wireless tswj
Technical Parameters of High Frequency Mobile X-ray Imaging System AMPX11:
X-ray generator:
1. Lub zog: 3.5kw
2. Tube voltage: 40-110kV, txhua 1kV
3. zaus: siab zaus, 40kHz
4. Tube txiaj: 70mA
5. Lub sij hawm raug: 0.04-3.2s;Radiography mAs 1-250mAs (adjustable)
8. Wireless exposure tej thaj chaw deb maub los
Tube:
1. Dual tsom: 0.6mm / 1.5mm;
2. lub kaum sab xis anode: ≤12 °, anode tshav kub muaj peev xwm: ≥200KHu;
3. beam splitter rotating ntau yam: ± 90 °, nrog taw qhia teeb;
4. x ray leak: ≤0.2mGy/h
Mobile sawv:
1. tag nrho chav tsev collapsible, X ray tube ntsug motion range: ≥1200mm;
2. lub kaum sab xis rotating: ± 90 °;
3. nrog cov neeg kho tshuab nres;
4. Muaj ntau yam rau lub taub hau tig, yooj yim positioned thaum yees duab;
Standard Configuration of High Frequency Mobile X-ray Imaging System AMPX11:
1. Modular high-frequency thiab high-voltage X-ray generator;High-frequency inverter zog (3.5KW, 110KV, 70mA, 40KHZ) ib txheej
2. Lub xov tooj txawb X-ray yees duab Lub ntsiab ncej ib txheej
3. Txawb X-ray yees duab tswj qhov system ib txheej
4 .Symmetric adjustable beam limiter nrog lub teeb ib txheej
5. 12 "X 15" Image Intensify, Cassette, Grid ib txheej
6. General spare xeem Ob peb
Client siv cov duab ntawm High Frequency Mobile X-ray Imaging System AMPX11
Thov hu rau peb kom paub meej ntxiv