Specification
Amain AMDA300V2 High anesthesia veterinaria instrumento pretioso cum evacuatione systematis administrandi.Idoneum est valetudinarium animal, pet clinicum et laboratorium animal.Haec technica index anesthesiae animalis machinae necessitatibus occurrere potest anesthesiae generalis et investigationis medicinae in muribus, canibus, felibus, leporibus, simiis, porcis, ovibus et aliis animalibus in laboratorio animali.
Technical Specification
Vet Anesthesia ventilator
Respirationis modus
PCV, VCV, SPONT, DEMO
mugitus
Magnum animal t : 50-1600ml , animal parvum : 0-300ml
Screen
IX pollices tactus screen
Waveform
Pressura, fluere, Volume
Loop
PV, PF, FV
Thadal volumen
Mechanica control20-1600ml
Manuale imperium:5-1600ml
BPM
1-100bpm
I:E
9.9:1to1:9.9
Inspiratorii tempore
0.1s-10.0s
Apnea
0-50%
PEEP
Off,3-20cmH2O
Pressura auxilium
5-60cmH2O
Influunt felis
0.5-20L/min
Pressura felis
-1~20cmH2O
PSV Inspiratorii terminales
25%
Cras
Thadal volumen, spirans rate, Spontaneus spirans rate,I:E, Spontaneus minutus evacuationis volumen,Minutum evacuatione apicem airway
pressura, Mediocris airway pressura, CONTUITUS, Inspiratorii suggestum pressura, FIO2
Metum parametri
Thadal volumen, Minutum evacuatione volumen, Frequency, Airway pressura, continuum airway pressura, negativa pressura terrorem, Apnea
terrorem, aeris copia pressionem deficiendi terrorem, potentia copia terrorem, Maximum altilium terrorem, Pugna defatigatio terror, Oxygen pugna deficiendi
terror, FIO2 (libitum), FICO2 (libitum)
Potentia copia
220V±10%,50HZ±1%
Vet Main unitas
VENTILATIO modus
Apertum, occlusum, dimidium-clausum, dimidium-apertum
Coegi modus
pneumaticum
Applicationem
0.5-100kg animal
Anesthesia Vaporizer
Isoflurane, Sevoflurane, Halothane
Oxygen Flush
25L/min~75L/min
Gas fons pressura
Oxygen 0.25Mpa~0.65Mpa
Trolley
Qualitas aluminii mixturae profile, cum repositione compage et peculiari instrumento ad gas emissionem exhauriendam
Influunt meter
Oxygeni metri causa fluunt animalia;
Scale range:0~5L/min
CO2 Absorber
Sodium Lime Tank Capacity
500ml-700ml
Absorber
Ambitus specificati animalis integrati potest in caliditas et pressione alta 134 .Dedicatum interface
coniungi potest cum ambitu aperto, parvis animalibus humili fluxu apta.
Valvae pars
Visibilis valvae ceramicae fragmentum, facile ad respirationem animalis observandam.
Pop off valvae
Gas anestheticum vastum a machina ad scavenging systema dirigit.In loco omnino aperto, valvae pop-off will
pressionem emittere ad 2 cm H2O, constantem volumen passivum in saccis spirantibus conserva.
Alia utilitas
Fortis aeris emissiones, reducere airway resistentia;Design est velox reponenda sodium calcis Canister
Anesthesia Vaporizer
Retrahitur scope
Isoflurane:0.2%~5%
Sevoflurane: 0.2%~8%
Influunt rate scope
0.2L/min~15L/min
Anesthetic facultatem
Arida :340ml
Infectum : 300ml
Adscendens genus
Selectatec vel Cagemout
Configurationis
Standard
Praecipua unitas ,Oxygen gasi copia caligarum, pressionis cylindrici regulator, Anesthesia vaporizer, Trolley, Animal respirans circuitus, Exhauriunt gas
effusio systematis, intubationis arteriae, larva anesthesia animalis, anesthesia throato scope, sodium calx
Option
Ambitus non-Spiritus, Activa carbonis
Product Features

* dolor 9-unc tactus velamentum;machina anesthesia integrata cum ventilator, sumptibus laboris salvis
* Respirationis modi includunt PCV, VCV, SPONT, DEMO. Sicut pondus pone, alii parametri calculi automatice
* Cum Electric PEEP munus
* Animal-speciale folles designant ad necessitates investigationis scientificae clinicae.
* Pugna interna plus duabus horis adhiberi potest.
* Minimis animalibus idoneum, circuli Non respirandi (Jackson vel Bains Absorber) praesto est.
*Selectatec-barbarum et fabricam inscendens velox mutationis vaporizer.
* Professio airtight respirationis circa consilium, anesthesiam gasi stabilem praebe, praeter anaesthesiam gasi consummationem, ut locus mundus operans et ambitus laboratorium curet.
* Externe et reusable nitri calcis calx, facile vigilare et nitro calcis reponere.
* Apud Oxygen rubor munus est curare ut orci anesthesia postulabit et Oxygeni copiam postulant.
* Anesthesia CO2 absorber conventus nullum habet angulum mortuum consilio, ieiunium anesthesia, brevi recuperatio et summa cura.CO2 absorber sustinet et anasthesiam apertam et anesthesiam anesthesiam clausam designans et accessum independentem praebet.
* Praebere specialem POP-Off valvae, Occlusionis designatio, ad lassitudines systematis recuperationis exhauriendae coniungi potest et continuam 2 cmH2O pressionem negativam pro reaspirato airbago praebere, valvulam reducere ne pressionem animalis laedat, salutem animalis curet.
* accurate oxygeni fluxum metri praebet cum ostentatione range of 0 ad 5LPM .
* Vaporizer: output concentration non afficitur mutatione fluxus, pressionis et caliditatis, accuratae et certae, instructae cum salute densis notae ne anesthetic ultrices.Isoflurane, sevoflurane et halothane vaporizer sunt libitum.
* Aluminium durum cortice solido adhibetur, et summa curatione ARENATIO adhibetur, quo commodior est purgatio et disinfection.
* Visibilis inspiratione et respiratione valvae
* Cum recens gas output iungo, specialiter ordinatur ad humilis fluxus accomodare


  • Priora:
  • Deinde:

  • Epistulam tuam relinque:

    Epistulam tuam hic scribe et mitte ad nos.

    Epistulam tuam relinque:

    Epistulam tuam hic scribe et mitte ad nos.