Velox Details
Amorphous pii TFT/PD tabula matrix
Scintillator Csi (TI)
Pixel picis 85µm
Effective active area 235mm x 290mm
Efficax pixel matrix 2762 x 3408
AD conversionem 16bit
Programmable quaestum amplificatorem
Energy range 25kV-40kV
AED Trigger modus Software
Packaging & Delivery
Packaging detail: Latin export sarcina Partus detail: in 7-10 fes post recepcionem solucionis |
Specifications
Pectus Flat Panel Detector AMFP30 for sale|Medsinglong
1.Introductio
TheAMFP30digital FPD detector cum Patente Amorphoi Siliconis TFT sensoris et acus directe deposita CsI: Tl scintillator ars technologiae irae.It ordinatur cum forma pacti ut retrofit analog mammographiae systematis digitali.AMFP30satis amplam aream activam 24x30cm cum 85μm pixel habet.Usus est CSI * (Cesium Iodide) scintillator facit the AMFP30 consequi a speciale summus DQE et MTF.Detector AED (Auto expositionis Detection) munus praebet per sensorem specialem ad X radium ad FPD activum detegendam, et etiam compatible cum AEC functione mammographiae systematis analogicis.AMFP30sustinet FFDM utilibus.
- General ars Specifications
Sensorem technology | Amorphous pii TFT/PD tabula matrix |
Scintillator | Csi (TI), acus directe in tabella Si TFT posita |
Pixel picem | 85µm |
Active area efficax | 235mm x 290mm |
Efficax pixel matrix | 2762 x 3408 |
AD conversionem | 16bit |
crimen amplifier | Programmable quaestum amplificatorem |
Energy range | 25kV-40kV |
DataControl interface |
GigE |
Modus felis | Software, AED |
AED munus | Ita |
Modus imaginis | 2fps @ Free run |
exolvuntur tempore | Typical 15s |
- Image Quality
Limited loci resolutio | 6 lp/mm |
Saturatio dosis* | Typical 2500μGy @ 7.2pC |
Dynamic range* | >76dB @ 7.2pC |
QNED (Metietur secundum pretium Europae) |
FFDM: ≤20µGy @ Binning 1C |
QVLD (Metietur secundum pretium Europae) |
FFDM: ≤80µGy @ Binning 1C |
Linearity* | ≥ 0.999 |
MTF* @ RQM1/Binning1C (IEC62220-1-2 secundum metiri) | Typical 90% @ 1.0 LP/mm Typical 70% @ 2.0 LP/mm Typical 58% @ 3.0 LP/mm Typical 29% @ 5.0 LP/mm |
DQE* @ RQM1/Binning1C (IEC62220-1-2 secundum metiri) | Typical 69% @ 0 LP/mm Typical 65% @ 1.0 LP/mm Typical 56% @ 2.0 LP/mm Typical 45% @ 3.0 LP/mm Typical 31% @ 5.0 LP/mm |
Lag (IEC62220-1-2 secundum metiri) |
<1.5% (prima frame) |
Memoria effectus | <0.3%, post 60s |
(IEC62220-1-2 secundum metiri) |
|
CNR @ 45mm PMMA | ≥ 12.5 |
Receptor homogeneitatis imago (Metietur secundum pretium Europae) |
<10% |
ACR phantasma @ conditionis orci | ≥ 4 fibris ≥ 4 missarum ≥ 3 festucam coetus |
Desiderari TEXTUS ad pectoris parietem | <3 mm |
*: Radiatio qualitatis est W/Rh (50µm) secundumIEC62220-1-2:2007.
- Mechanica
Pondus | ≤1.3kg |
Praesent materia | Aluminium cum fibris laminatis carbonis ostium fenestra |
Magnitudo (mm3) | 327 (L) 254.5 (W) 14 (H). |
Adumbrare |
|
- Communications
Data interface | GigE |
X-ray synchronisation interface | AED |
Software | SDK, sustinens 32 et 64 Windows®OS |
- Environmental et Reliability
Temperature | 10 – 40 °C (operatio), -10 – 55 °C (repono) |
Umor | 10 - 90% RH (operans, non-condensans) 10 - 95% RH (repono) |
Pressura | 700 - 1060mbar (operatio et repositio) |
Vibratio | IEC 60068-2-6 (10-200 Hz, 5 g); |
Offensus | IEC 60068-2-29 (16ms, 10 g) |
Vita | V annis |
Vita tempus dose | Typical 300Gy |
IBFR | ≤ 2.5% |
CFR36 | ≤ 7.5% |
- Potestas
Supply | 100-240V AC et frequentia 50Hz et 60Hz, utraque +/- 2%. |
Input | 24V DC |
Dissipatio | circum 18W |
Refrigerium | passivum |
- Regulatory
Generalis regulatory | CE, RoHs |
Periculo procuratio | ISO 14971: 2007 |
Salus et essentialis perfor mance | IEC60601-1:2005/EN60601- 1:2006+AC:2010/IEC 6001-1:2005+ Emendatio 1:2012/EN 6001-1:2006+ Emendatio 1:2013 IEC 6001-1-2: 2014 |
Radiatio praesidium | IEC 6001-1-3:2008 |
Characteres digitales X-ray imaginantes cogitationes | IEC 62220-1-2:2007 |