Velox Details
Capacitas consequat
Max aestimavit facultatem: 3.5 KW
Tubus Voltage et Current deducto:
40kV~49kV 1 ~125 mAs
50kV~59kV 1 110 mAs
60kV~69kV 1 90 mAs
70kV~79kV 1 80 mAs
80kV~89kV 1 71 mAs
90kV~99kV 1 63 mas
100kV~110kV 1 40 mAs
Plateholder Size:
200mm×250mm(8″×10″)or
250mm×300mm(10″×12″)
Packaging & Delivery
Packaging detail: Latin export sarcina Partus detail: in 7-10 fes post recepcionem solucionis |
Specifications
Features of High Frequency Mobile C-arm System AMCX32:
1. New integrated design, compact appearance, convenient operation.;
2. Singularis manus-tenuit remota moderatoris, commodior operandi
3. Graphicum perdiligenter LCD tactum velum consolatorium interfaciem, operationem convenientem, designativam modum
4. Qualitas HF-HV X generantis - radius componitur, valde reducens X radium irradiationem.
5. Toshiba imago intensior adhibita, stabilis et certa in qualitate, summus definitionis ratio et ratio ostentationis.
6. Perspectiva KV, MA automatice lineamentum sequi, imago claritas ac definitio statim ad munus optimale constituuntur.
7. Medici summus senatus motus in TV systematis progressivus, octo imaginum repositio, imago clarior et operatio opportuna.
Specification of High Frequency Mobile C-arm System AMCX32:
1.Fluoroscopic Capacity
Max aestimavit facultatem: Tubus Current 4mA, Tube Voltage 110kV
Lorem Fluoroscopia: Tubus intentione: 40kV~110kV Automatarie adjust, Tubus Current: 0.3mA ~ 4mA pone manually
Manual Fluoroscopia: Continua Tube Voltage: 40kV~110kV, continuus Tubus Current: 0.3mA~4mA
Pulsus Fluoroscopia: Continuus Tube Voltage 40kV~110kV, Continuus Tube Current 4.1mA~8mA
2. Photography Capacity
Max aestimavit facultatem: 3.5 KW
Tubus Voltage et Current deducto:
40kV~49kV 1 ~125 mAs
50kV~59kV 1 110 mAs
60kV~69kV 1 90 mAs
70kV~79kV 1 80 mAs
80kV~89kV 1 71 mAs
90kV~99kV 1 63 mas
100kV~110kV 1 40 mAs
Plateholder Size:
200mm×250mm(8″×10″)or
250mm×300mm(10″×12″)
3.X-ray tube
X-ray Tube Special ad High Frequency
Anode fixum Dual-focus : focus magnus: 1,5, focus parvus: 0.6
Inverter Frequency: 40KHz
Facultas scelerisque: 35KJ (47KHU)
4.VideoSystem
Imago intensifier: imago intensior facta ab TOSHIBA (9″、 6″、4.5″)
CCD Vidicon: Ultra leve CCD camera ex Iaponia importata
Monitor: Horizontalis 1000 lineae et perpendiculi 800 lineae;
Bandwidth : 12.5MHz, Image/sec : 75
CCU (potestas centralis) : Filter recursivus: K=8, 8 imagines reposita, imago recta, imago overturn,positiva & negativa;LIH (imago ultima congelatur, ostentatio OSD(monitor)
5.Structure:
Rota directiva : ±90° revolution, libere mutare directionem unitatis movens.
Ascendens & Descendens Teli columen: ≥400mm
C-brachium;
Motus ante et retro: 200mm
Revolution circa Axis Horizontalis: ± 180°
Revolutio circa axem verticalem : ± 15° ( Commodum ) melius quam alii ' ± 12.5°
Lapsus in orbita: 120°(+90°~ -30°)
Configurationis Altae Frequency Mobilis C-arm System AMCX32:
1.New (cum auxilio electrico bracchii auxiliaribus) C-arm main eculeo: unus paro
2.High-frequency summus voltage X-ray generator and high-frequency inverter power supply (3.5KW、40KHZ、110KV)
3.Toshiba IX inch imaginem intensifier: unus paro
4.1 decies centena pixel ultra-low-lux digital cameras: unus paro
5. high- definition progressive output CCU main-control system: one set
6.High-crassitudo grids: unus paro
7.Electric Novifacta collimatorne set
8.23-inch summus definitio medicinae monitor: unus paro
9.Unique manu-tenuit remote controllerne set
Client Usage Photos of High Frequency Mobile C-arm System AMCX32
Quaeso, contact us pro magis details.