H7c82f9e798154899b6bc46decf88f25eO
H9d9045b0ce4646d188c00edb75c42b9ek

AM Touch Screen Multi-Parameter Patient Monitor AMMP09 for sale

Description:

Product nomen:Tactus Screen Multi-parameter patiens Monitor AMMP09
Tardus Price: US$ 600-3077/Set

Exemplar No.:AMMP09
Pondus:Net pondus: Kg
Minimum Quantitas Ordinis:I Set / Sets
Facultates copia:CCC Sets per Year
Pensio conditio:T/T,L/C,D/A,D/P, Unio occidentalis, MoneyGram, PayPal


Product Detail

Product Tags

Velox Details

Plug-in rechargeable altilium, AC/DC in promptu sunt.

Cardiotocography, ctg apparatus, ctg apparatus pretium, ctg apparatus sumptus.

Packaging & Delivery

Packaging detail: Latin export sarcina
Partus detail: in 7-10 fes post recepcionem solucionis

Specifications

Tactus Screen Multi-parameter patiens Monitor AMMP09

12.1" color TFT tactus screen

Windows stilum, Multi-canalem ostentationem Big fontis interface ST et arrhythmia analysis medicamentum dosis calculo et titratione mensa OxyCRG dynamica visui ostentus Respiratio vigilantia cum apnea terroribus metum review, arrhythmia review Patient info.Input Anti-defibrillation design NIBP super pressione protectionis Plug-in rechargeable altilium, AC/DC in promptu est.Filum sustentans vel wireless retis.Cardiotocography, ctg apparatus, ctg apparatus pretium, ctg apparatus sumptus. Adoptatione Aiah(TM) ECG technologiae, anti-impedimenti, signum infirmum ECG ab impedimento colligere poterit.Adoptatione Surepeb(TM) NIBP technologiae, accurate mensuras ad sanguinem pressionis altum patientem et humilem sanguinis pressionem patientem.SP02 Nellcor(TM) OxiMax(TM) est mundus qui SpO2 technologiam Nellcor(TM) OxiMax(TM) praecellens effectionem tradit, etiam in difficilioribus condicionibus perfusionis gravis et magnae impedimenti, etiam motus patientis.ETCO2 Collaborate cum Respironicis, Plug et Play EtCO2 vigilantia.CAPNOSTAT amet sensorem ad optimalem observantiam in vigilantia patientis intubati.Parvum, durabile et leve sensorem amet, accurate et certa vigilantia omnibus aegris intubatis ab neonatis ad adultis praebet.Loflo sensorem lateralem ad patientem vigilantiam non-intubatam.Flexibile, compactum CO2 sensorem praebet constantem et certam vigilantiam aegrorum adultorum, pediatricorum et neonatalium.Cardiotocography, ctg apparatus, ctg apparatus pretium, ctg apparatus sumptus.ECG Modus V Leads (R, L, F, N, C vel RA, LA, LL, RL, V) Lectio I, II, III, avR, avL, avF, V Wave form 2 ch. 3 Leads (R, L, F vel RA, LA, LL) Lectio I, II, III, Wavef orm 1 ch Lucrum 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto HR et metum Range Adulta 15~ 300 bpm Neo/Ped 15~350 bpm Accuracy ±1% vel±1bpm, quae maior est Resolutio 1 bpm Sensibilitas > 200 (uVp-p) Differentialis Input Impedimentum > 5 MΩ CMRR Monitor > 105 dB Operatio > 105 dB Diagnosis > 85 dB Electrode cinguli potentialis ±300mV Leakage Current < 10 uA Baseline Recuperatio <3 S Post Defi.ECG Signum Range ± 8 m V ( Vp-p ) Bandwidth Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz Calibration Signum 1 (mVp-p), Accuracy:5% ST Segmentum Monitoring Range Mensura et Alarm -2.0 ~ +2.0 mV ARR Deprehensio Type: ASYSTOLE, VFIB/VTAC, COPULATIO, BIGEMINY, TRIGEMINY, R ON T, VT>2, BRADY, BEATS PRAETERITUS, PNP, PNC, Terror Available, Recognoscere Available cardiotocographia, ctg apparatus, ctg apparatus pretium , ctg apparatus sumptus.Respirationis Methodo Impedimentum inter RF(RA-LL) Differentialis Input Impedimentum > 2.5 MΩ Mensuratio Impedentiae Range 0.3~3 Ω Base linea Impedantia Range 200~4 KΩ Bandwidth 0.1~2.5Hz Resp.Rate Mensuratio et Alarm Range Adulta 0~ 120 Brpm Neo/Ped 0~ 150 NIBP Methodus Oscillometric Modus Manuale, Auto, STAT Mensurandi Intervallum in Auto Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min) Mensurans Period in STAT Modus 5 Min Pulsus Rate Range 40 ~ 240 bpm Alarm Type SYS, DIA, MEAN PROFESSIONALIS Patiens Monitor AMMP09 Mensurans et terror range Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20~ 235 mmHg Modus Pediatricus SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20~ 165 mmHg Neonatalis Modus SYS 40 ~ 135 mmHg DIA 10~ 100 mmHg MEAN 20~ 110 mmHg Resolutio 1mmHg Accuracy Maximus Error Medius ±5mmHg Maximus Standard Declinatio ±8mmHg Overpressure Protection Adult Modus 297±3 mmHg Modus Pediatricus 240±3 mmHg Modus Neonatalis 147±3 mmHg SpO2 Mensuratio Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolutio 1 % Accuracy 70% ~ 100% 2% 0% ~ 69% Actualization intervallum 1 Sec.Terror Tarditas 10 &c.Pulsus Rate mensurans et metum dolor 20~ 300 bpm Resolutio 1bpm Sagax ±3bpm TEMP Channe 2 Mensuratio et metum Teli 0 ~ 50 Resolutione 0.1 Accuracy ± 0.2 Actus interuallorum circiter 1 Sec.Mediocris Tempus Constant < 10 Sec.IBP Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Mensuratio et terror range ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP-10 ~ 40 mmHg P1 / P2-10 ~ 300 mmHg Press Sensor Sensor 5 uV/V/mmHg Impedimentum 300-3000Ω Resolutio 1 mmHg Accuracy ± 2% seu 1mmHg quod est intervallum Actualization maius de 1 scriba Latin: ECG, Respiratio, NIBP, SpO2, Pulsus Rate, Temperature Libitum: Nellcor SpO2, EtCO 2, IBP, Recordator Thermal

AM Team picture

 

 

 

AM Quisque

   

 

AM Medical cooperatur cum DHL, FEDEX, UPS, EMS, TNT, etc. Societas navicularum internationalium, fac bona tua ut tuto et cito perveniant.

 

Grata ad medicalequipment-msl.com,Si quid petis in monitore patienti.Placet sentire liberum to

contactuscindy@medicalequipment-msl.com

 

 


  • Previous:
  • Deinde:

  • Epistulam tuam relinque:

    Epistulam tuam hic scribe et mitte ad nos.

    Epistulam tuam relinque:

    Epistulam tuam hic scribe et mitte ad nos.