H7c82f9e798154899b6bc46decf88f25eO
H9d9045b0ce4646d188c00edb75c42b9ek

Navigator Platinum Mammography AMRX01

Description:

Product nomen:Navigator Platinum Mammography AMRX01
Tardus Price:

Exemplar No.:AMRX01
Pondus:Net pondus: Kg
Minimum Quantitas Ordinis:I Set / Sets
Facultates copia:CCC Sets per Year
Pensio conditio:T/T,L/C,D/A,D/P, Unio occidentalis, MoneyGram, PayPal


Product Detail

Product Tags

Velox Details

Systema Mammographiae

a) Standalone System (Integrated in the main machine)

b) Generator: 100 kHz, 20 kV ad 40 kV in 1 kV

c) Tubus X-radius High perficientur: Molybdenum Anode, Macula Focal Size: 0,1 mm (Small) / 0.3 mm (Large)

d) Support ISO centrum gyrationis munus

e) C-brachium Rotationis range: +180°/-135°

f) Altitudo amplitudo superficiei pectoris firmamentum: 750mm-1330mm(±2%)

g) C-arm: Motus Motorisatus, Dual latus digitalis ostentus

h) Cogo Paddles: Dual Smert Cogo Mechanismum

i) Resolutio spatii: ≥15Lp/mm

j) Film size: 18*24cm

k) Arx distantia: 650mm

l) Additional filter: 0.03mm Molybdenum / 0.5mm Aluminium

m) Additional filter Insemination: Lorem

n) Field temperatio: Auto / Manual

o) Magnificationis ratio: (1.6)/1-(1.8)/1 .

p) Modus expositionis: Manuale / AEC/AAEC

q) Potentiae copia: una periodus AC 220~ 230 V±10%

r) Frequentia: 50/60 Hz±1 Hz

s) Maximilianus.potentia : 5000 KW

t) NW: 240 Kg

u) Packing Size: 115 X 85 X 135 CM

 

Packaging & Delivery

Packaging detail: Latin export sarcina
Partus detail: in 7-10 fes post recepcionem solucionis

Specifications

Navigator Platinum Mammography AMRX01

Systema Mammographiae

a) Standalone System (Integrated in the main machine)

b) Generator: 100 kHz, 20 kV ad 40 kV in 1 kV

c) Tubus X-radius High perficientur: Molybdenum Anode, Macula Focal Size: 0,1 mm (Small) / 0.3 mm (Large)

d) Support ISO centrum gyrationis munus

e) C-brachium Rotationis range: +180°/-135°

f) Altitudo amplitudo superficiei pectoris firmamentum: 750mm-1330mm(±2%)

g) C-arm: Motus Motorisatus, Dual latus digitalis ostentus

h) Cogo Paddles: Dual Smert Cogo Mechanismum

i) Resolutio spatii: ≥15Lp/mm

j) Film size: 18*24cm

k) Arx distantia: 650mm

l) Additional filter: 0.03mm Molybdenum / 0.5mm Aluminium

m) Additional filter Insemination: Lorem

n) Field temperatio: Auto / Manual

o) Magnificationis ratio: (1.6)/1-(1.8)/1 .

p) Modus expositionis: Manuale / AEC/AAEC

q) Potentiae copia: una periodus AC 220~ 230 V±10%

r) Frequentia: 50/60 Hz±1 Hz

s) Maximilianus.potentia : 5000 KW

t) NW: 240 Kg

u) Packing Size: 115 X 85 X 135 CM

Navigator Platinum Mammography AMRX01

Princeps Frequency High Voltage Generator

a) Type: una periodus, Constant High Frequency Generator

b) Frequentia Laborans: 100 kHz

c) Maximilianus.Output: 3.5 kW

d) kV Range: 20 kV ad 40 kV in 1 kV incrementa

e) Tube mA Range: 15mA ad 110 mA

f) mAs range: 10~ 600mAs

X-Ray Tube

a) Anode Type: Molybdenum

b) Macula Focal Size: 0,1 mm (Small)/ 0.3 mm (Magnum)

c) Filtrum fixum: 0.5mm Be

d) Additional filter: 0.03mm Molybdenum / 0.5mm Aluminium

e) Anode Speed: 3000rmp/min

Maximini.Celeritate: 10000rmp/min

f) Tube mA Range: 35mA (Focale Parvum)/140mA (Arx magna)

g) Anode capacitatem calefactionis: 320 KJ/416KHU

C-brachium Conventus

a) Motus C-brachii: omnes Motorised

b) ISO centrum rotationis: Sic

c) Position location: CC,OBL, LAT

d) C-brachium Rotationis range: +180° ad -135°

e) C-arm range: 1385mm~1965mm (±1%)

f) Arx distantia: 65cm

g) latus pes switch imperium

h) Propositio digitalis rotationis C-brachii et crassitudinis in utraque parte C-brachii

i) tumultuarios "Off" switch pro addita salute et operator imperium

j) Dual Smert Cogo Mechanismum

Navigator Platinum Mammography AMRX01

Cogo Paddles (Smert REMUS System)

a) Digital Propono vis compressionis in utraque parte C-brachii

b) Dual Smert Cogo Mechanismum

c) Smert Cogo Mechanismus: Motorised sursum et deorsum, mollis compress, auto emissio, manual de-compresso

d) Paddles Iter dolor: 268mm

e) Compressio Range: 0~196N (20 kg), incrementum 9.8 N (1 kg)

Potestas Capacity 4000VA
Voltage 220V AC Single Phase
Frequentia 50Hz/60Hz
Humus requisita Minus quam 0.6Ω
Item Temperature Umor /Atmosphaera
Parameter -40 +55 ≤93% 700hPa~1060hPa
Item Temperature Umor atmosphaera
Parameter 10℃~40℃ 20%~80% 700hPa~1060hPa