Quick Details
Assay methods: End Point, Kinetic, Fix time etc. Principle: Photoelectric colorimetry Light Source: Halogen lamp 12V/20W Photometry range: 0~3.2Abs Resolution: 0.0001Abs Wavelength: 340nm405nm450nm492nm510nm546nm578nm630nm700nm800nm Throughput: 200 tests/hour Reagent tray: 60 reagent positions (include1detergent position,1 dilution position)
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
24 hour non-stop cooling Chemistry Analyzer machine URIT-8021A
Random access, 200 tests per hour Durable ceramic syringes Select best test point by reaction curve, create new factor automatically Support bi-direction LIS and HIS interface
Durable ceramic syringes Chemistry Analyzer machine URIT-8021A Features
24 hour non-stop cooling system to ensure reagent at 2-8℃ Durable ceramic syringes to ensure accuracy & precision High accurate optical system Collision protection in both vertical and horizontal directions, stop & alarm automatically once touching barrier, not affect former tests Automatic eligible cuvettes detection & selection Select best test point by reaction curve, create new factor automatically Support LIS interface
Automatic eligible cuvettes detection Chemistry Analyzer machine URIT-8021A Specifications
Assay methods: End Point, Kinetic, Fix time etc. Principle: Photoelectric colorimetry Light Source: Halogen lamp 12V/20W Photometry range: 0~3.2Abs Resolution: 0.0001Abs Wavelength: 340nm405nm450nm492nm510nm546nm578nm630nm700nm800nm Throughput: 200 tests/hour Reagent tray: 60 reagent positions (include1detergent position,1 dilution position) Sample tray: 71 sample positions, including detergent, standard, QC, STAT positions Reaction tray: 120 reaction cuvettes Sample volume: 2~100ul, with 0.1ul increment Reagent volume: R1:10~500uL, R2: 10~500uL,with 0.5uL increment Minimum reaction volume: 180uL Maximum reaction time: 10 minutes Water Consumption: Less than 5L/hour under working status Clean unit: 8-step auto-washing system with detergent Calibration: Calibration reset, select best test point by reaction curve, no need second calibration Line/non-line;multi-standards assay Control rules: Westgard multi-rule, Cumulative sum check, Twin plot 3 level controls for each ifem, analyxing and printing QC analysis diagram Temperature control: incubator 37±0.1℃ Power supply: AC 230(1±10%)V, 50/60Hz, 500VA Ambient: Operating temperature: 10~30℃ Relative humidity: ≤85% Atmospheric pressure: 86~106kPa High performance mixer design Absence of cross contamination Optimal homogenization in minimum time Mixing immediately after dispensing of sample and the second reagent Stable Optical System High accurate, close, static state optical system Spot photometry with high speed digital transmission system Durable cuvettes 8-step auto-washing system with detergent and deion-water to ensure cuvettes clean and decrease cross contamination 120 reaction cuvettes located in a constant temperature incubator Low consumption, open reagent design