Manufacturer for X-Ray Protective Products - AM-5500B 56kW digital gastrointestinal DRF X Ray machine – Amain Detail:
Product Description
Hospital equipment AM-5500B 56kW Two million digital gastrointestinal DRF digital X Ray machine
(56kW, 710mA)
I.ApplicationFull support perspective, gastrointestinal spot film, GI (barium meal, barium enema), orthopedic photography, pediatrics
photography, chest, urinary system angiography, peripheral angiography operations, gynecological Photography (HSG) and many other
checks, the real machine can realize all these function.Ⅱ.Digital system1).The system has excellent performance and high quality images, from the fluroscopy, spot film, sequence of all digital
photography collected to digital subtraction angiography (DSA) image processing. 2).Digital continuous/pulse fluroscopy: 1024 x
1024 matrix, 12 bit, 30 frames /s, with the function of LIH High quality digital spot film: 1024 x 1024 matrix, 12 bit, with the
function of AEC Sequence of high-speed photography collection: 1024 x 1024 matrix, 12 bit, 1 to 30 frames/s
photography, chest, urinary system angiography, peripheral angiography operations, gynecological Photography (HSG) and many other
checks, the real machine can realize all these function.Ⅱ.Digital system1).The system has excellent performance and high quality images, from the fluroscopy, spot film, sequence of all digital
photography collected to digital subtraction angiography (DSA) image processing. 2).Digital continuous/pulse fluroscopy: 1024 x
1024 matrix, 12 bit, 30 frames /s, with the function of LIH High quality digital spot film: 1024 x 1024 matrix, 12 bit, with the
function of AEC Sequence of high-speed photography collection: 1024 x 1024 matrix, 12 bit, 1 to 30 frames/s
Specification
Item | Content | Technical Parameters | Technical Parameter |
Power Supply | Voltage | 380V±38V | 220V / 380V |
Frequency | 50Hz±1Hz | 50Hz | |
Capacity | ≥65kVA | ≥40kVA | |
Internal Resistance | ≤0.17Ω | ≤0.15Ω | |
Generator (FSQ60) | Power | 56KW | 32KW |
Inverter Frequency | 440 KHz | 30 KHz | |
Radiography Tube voltage | 40kV~150kV step adjustment | 40kV—150kV | |
Radiography Tube current | 10mA~710mA step adjustment | 10mA—320mA | |
Radiography Time | 1.0ms~10000ms step adjustment | 1.0ms—6300ms | |
Radiography mAs | 0.1 mAs~900 mAs | 2.0mm /1.0mm (Large/Small Focus) | |
Fluoroscopy Tube voltage | 40kV~125kV step adjustment | Large/ Small focus: 47kW/ 25kW | |
Fluoroscopy Tube current | 0.5mA~10mA continuous fluoroscopy | 150KHU | |
5mA~20mA Pulse fluoroscopy | ≥900mm | ||
X-ray tube assembly (E7252X) |
Target | Molybdenum-based lanthanum-tungsten composite |
≥220mm |
Target angle | 12° | ≥1300mm | |
Nominal tube voltage | 150kV | ≥500mm | |
Tube Focus: big/small | 1.2mm / 0.6mm | 500mm-1280mm | |
Input power | Big Focus/ 75kW Small focus/ 27kW | Manual Multi-leaf | |
Anode thermal capacity | 210kJ(300KHU) | Grid density: 103L/INCH Grid ratio: 10:1 SID: 120cm Stationary type: 15″×18″ |
|
Anode maximum heat dissipation |
475W(667KHU/min) | ≥1300mm | |
Component heat capacity | 900kJ(1250KHU) | 450- 1780mm | |
Anode Rotation Speed | 9700rpm | Grid density 103L/INCH Grid ratio: 10:1 SID: 180cm Size: 15″×18″ |
Product detail pictures:
Related Product Guide:
We've numerous great employees customers excellent at promoting, QC, and working with kinds of troublesome difficulty inside the generation method forManufacturer for X-Ray Protective Products - AM-5500B 56kW digital gastrointestinal DRF X Ray machine – Amain, The product will supply to all over the world, such as: Austria, Salt Lake City, Algeria, Many products fully conform to the most rigorous of international guidelines and with our first-rate delivery service you will have them delivered at any time and in any place. And because Kayo deals in the entire spectrum of protective equipment, our customers don't need to waste time shopping around.