Quick Details
This anesthesia machine consists of a main unit, an anesthetic vaporizer, a flow meter, an anesthesia respirator and a respiratory circuit system.
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
Anesthesia Ventilator machine for sale-AMGA11
AM Anesthesia Ventilator machine-AMGA11 Overview
This AMGA11 Anesthesia Machine is an essential important anesthesia device in an operation room.Its function is to provide oxygen and anesthetic agent to a patient needing to go through an anesthesiaoperation and perform ventilation management.This anesthesia machine is intended for use in children and adults with a body weight heavier than 10kg.This AMGA11 Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and asafety device for preventing cyanosis and necessary alarm system. During the anesthesia, the patient’srespiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlledsynchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface.A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.
Operating conditions for AMGA11 Anesthesia Machine:
———Ambient temperature: 10 ~ 40 ℃ ;———Relative humidity: no higher than 80 %;——–Atmospheric pressure: 860 hPa ~ 1060 hPa.——–Power requirement: ~220-240V, 50/60Hz, 40VA, to be well grounded.——–Air source requirement: medical oxygen and laughing gas with a rated pressure rangingfrom 0.3 to 0.5MPa.Attention: the AC power supply used for the anesthesia machine must be well grounded.Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complyingwith ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gasvolume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirementsfor Safety and Basic Performance of Anesthesia System. Cheap Anesthesia Ventilator AMGA11 Structural Characteristics and Operating PrinciplesThis anesthesia machine consists of a main unit, an anesthetic vaporizer, a flow meter, an anesthesia respirator anda respiratory circuit system.
Best Anesthesia Ventilator for sale-AMGA11 Technical
1 Operating mode: circulatory closed, semi-closed and semi-open.2 Gas requirement: medical oxygen and laughing gas with a pressure ranging from 0.3MPa to 0.5 MPa.3 The maximum error of the pressure testing device should not exceed ± (4% of the full scale reading + 8%of the actual reading).4 For oxygen and laughing gas, a special pressure regulator with a safety valve will be provided. The exhaustpressure of the safety valve should not be higher than 6 kPa.5 Indication range of the oxygen and laughing gas flow meter: 0.1 L/min ~ 10 L/min.When the flow rate ranges from 10% of the full scale value to 100%, the scale accuracy should bewithin ±10% of the indicated value.6. The flow meter is equipped with an oxygen-laughing gas proportional control device.When the oxygen concentration in the mixed gas N2O/O2 conveyed by the anesthesiamachine is no lower than 20% (V/V) or the FiO2 is lower than 20%, the machine will emit analarm. 7. When the oxygen pressure of the anesthesia machine is 0.20MPa±0.05MPa, the machine raises a low gassource pressure alarm which is a high priority alarm, and shuts off the laughing gas conveyed to the common gas outlet.8. Oxygen Flush:25~75 L/Min;9. Anesthetic gas concentration adjustment range of vaporizer: 0~5%, relative error ±20 %.10. The exhaust pressure of the safety valve of the respiratory circuit is no higher than 6 kPa.11. Anesthesia ventilator11.1 Respiration Mode:IPPV,SIPPV,Manu11.2 Respiration Frequency:4~40bpm11.3 I/E Ratio:1:1.5~1:411.4 Tidal Volume:50~1500mL11.5 Ptr:-10~10hPa11.6 Controlled ventilation and assisted ventilation switching time: 6s11.7 Maximum safety pressure: ≤ 12.5 kPa.11.8 Pressure limit range: 1~6 kPa11.9 Airway pressure alarm: adjustment range of upper alarm limit: 0.3kPa ~ 6 kPa, permissible error ±0.2 kPa,or ±15% (whichever is greater), the machine should immediately raise a high level alarm when the airway pressurerises to the alarm value; the lower alarm limit ranges from 0.2 to 5 kPa and the permissible error is ±0.2 kPaor ±15% (whichever is greater). The machine should immediately raise a medium level alarm when the airwaypressure drops to the alarm value and such condition lasts 4 to 15s.3.11.10 Tidal volume alarm: the upper alarm limit ranges from 50 to 2000ml, the permissible error is ±20%,the adjustment range of the lower alarm limit is 0~1800ml, the permissible error is ±20% and the machineshould raise a medium level alarm. 3.11.11 Ventilation volume lower alarm limit: the adjustment range is 0~12 L/min , and the permissible erroris ±20%. The ventilation volume upper alarm limit is fixed to be 25 L/min, the permissible error is ±20%and the machine should raise a medium level alarm.3.11.12 Power supply fault alarm: the machine should give audible alarm in case of power outage and thealarm should last more than 120s. 3.11.13 The silencing time of the audible alarm signal should be less than 120s. The alarm status should notbe deactivated and visual alarm signal should not be intermittent. 3.11.14 The emergency battery should be a lead acid battery with a rated output voltage of DC 12V. The durationof the operation of the anesthetic respirator driven by the battery should be more than 60min.