Quick Details
12.1″ color TFT screen
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
Display screen vet patient monitor for sale AMMP06
12.1″ color TFT screen
Multi‐channel display Big font interface ST and arrhythmia analysis Drug dose calculation and titration table OxyCRG dynamic view display Respiration monitoring with apnea alarms Alarm review, arrhythmia review Patient info. Input Anti‐defibrillation design NIBP over pressure protection Plug‐in rechargeable battery, AC/DC available. Supporting wire or wireless network.
AM vet patient monitor for sale AMMP06 Technical Specifications
ECG Lead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) Lead selection I, II, III, avR, avL, avF, V Wavef orm 2 ch Lead mode 3 Leads ( R, L, F or RA, LA, LL) Lead selection I, II, III, Wave form 1 ch Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto HR and Alarm Range Adult 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpm Accuracy ±1% or±1bpm, which is greater Resolution 1 bpm Sensitivity > 200 (uVp-p) Differential Input Impedance > 5 MΩ CMRR Monitor > 105 dB Operation > 105 dB Diagnosis > 85 dB Electrode offset potential ±300mV Leakage Current < 10 uA Baseline Recovery < 3 S After Defi. ECG Signal Range ±8 m V ( Vp-p ) Bandwidth Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz Calibration Signal 1 (mVp-p), Accuracy:5% ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,Alarm Available,Review Available Respiration Method Impedance between R-F(RA-LL) Differential Input Impedance > 2.5 MΩ Measuring Impedance Range 0.3~3 Ω Base line Impedance Range 200~4 KΩ Bandwidth 0.1~2.5Hz Resp. Rate Measuring and Alarm Range Adult 0 ~ 120 Brpm Neo/Ped 0 ~ 150 Brpm Resolution 1 Brpm Accuracy ±2 Brpm Apnea Alarm 10 ~ 40 S NIBP Method Oscillometric Mode Manual, Auto, STAT Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min) Measuring Period in STAT Mode 5 Min Pulse Rate Range 40 ~ 240 bpm Alarm Type SYS, DIA, MEAN Measuring and alarm range Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg Resolution 1mmHg Accuracy Maximum Mean error ±5mmHg Maximum Standard deviation ±8mmHg Overpressure Protection Adult Mode 297±3 mmHg Pediatric Mode 240±3 mmHg Neonatal Mode 147±3 mmHg SpO2 Measuring Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 1 % Accuracy 70% ~ 100% 2 % 0% ~ 69% unspecified Actualization intervalabout 1 Sec. Alarm Delay 10 Sec. Pulse Rate Measuring and Alarm Range 20~300 bpm Resolution 1bpm Accuracy ±3bpm TEMP Channel 2 Measuring and Alarm Range0 ~ 50 ℃ Resolution 0.1 ℃ Accuracy ±0.2 ℃ Actualization intervalabout 1 Sec. Average Time Constant < 10 Sec. IBP Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and alarm range ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP-10 ~ 40 mmHg P1 / P2-10 ~ 300 mmHg Press Sensor Sensitivity 5 uV/V/mmHg Impedance 300-3000Ω Resolution 1 mmHg Accuracy ±2% or 1mmHg which is greater Actualization interval about 1 secretary Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature Optional: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder