Quick Details
Assay methods: End Point, Kinetic, Fix time etc. Principle: Photoelectric colorimetry Light Source: Halogen lamp 12V/20W Photometry range: 0~3.2Abs Resolution: 0.0001Abs Wavelength: 10 wavelengths optional (340nm~800nm) Throughput: 330tests/hour Reagent tray: 59 reagent positions, 1 detergent position
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
Biochemistry Automatic Chemistry Analyzer URIT-8210
Random access, 330 tests/hour ISE and barcode (Optional) 10-wavelength, high accurate and closed optical system Unattached probe and mixer Supports LIS system
High accurate optical system Automatic Chemistry Analyzer URIT-8210 Features
24 hour non-stop cooling system to ensure reagent at 2-8℃ Dual-unattached durable ceramic syringes to ensure accuracy & precision Collision protection in both vertical and horizontal directions, stop & alarm automatically once touching barrier, not affect former tests Automatic eligible cuvettes detection & selection Select best test point by reaction curve, create new factor automatically High accurate optical system Support LIS interface
High accurate optical system Automatic Chemistry Analyzer URIT-8210 Specifications
Assay methods: End Point, Kinetic, Fix time etc. Principle: Photoelectric colorimetry Light Source: Halogen lamp 12V/20W Photometry range: 0~3.2Abs Resolution: 0.0001Abs Wavelength: 10 wavelengths optional (340nm~800nm) Throughput: 330tests/hour Reagent tray: 59 reagent positions, 1 detergent position Sample tray: 71 sample positions, including detergent, standard, QC, STAT positions Reaction tray: 90 reaction cuvettes Sample volume: 2~100ul, with 0.1ul increment Reagent volume: R1:10~500uL, R2: 10~500uL,with 0.5uL increment Minimum reaction volume: 150uL Maximum reaction time: 10 minutes Water Consumption: 6L/hour under working status Clean unit: 8-step auto-washing system with detergent and 37℃ water Calibration: Calibration reset, select best test point by reaction curve, no need second calibration Line/non-line;multi-standards assay Control rules: Westgard multi-rule, Cumulative sum check, Twin plot 3 level controls for each ifem,analyxing and printing QC analysis diagram Temperature control: incubator 37±0.1℃ Power supply: AC110/230(1±10%)V,50/60Hz,500VA Ambient: Operating temperature: 10~30℃ Relative humidity: ≤85% Atmospheric pressure: 86~106kPa High performance mixer design Absence of cross contamination Optimal homogenization in minimum time Mixing immediately after dispensing of sample and the second reagent Efficient reaction system Reaction disk: 90 semi-permanent plastic cuvettes Minimum reaction volume:150 μl Operating temperature: 37℃, Temperature fluctuation:±0.1℃