Amain application of high frequency small linear array vascular access

In 2017, an epidemiological study in China reported that the number of adults with chronic kidney disease in China reached 130 million. Hemodialysis is one of the main ways of kidney replacement therapy, and the quality of vascular access largely determines the life span and quality of life of hemodialysis patients. Amain high-frequency small line array can clearly display the anatomical structure and cross-section images of blood vessels, provide dynamic information, and can be repeatedly operated anytime, anywhere, throughout the whole process of vascular pathways.

Amain high frequency small line array advantage

· 64 channels, 128 arrays, clear imaging;

· GPU architecture, zero delay without delay, puncture more secure;

· WI-FI connection, built-in battery, second to second connection;

· B, C, PW mode, one-key measurement of blood flow rate;

· Light body, the whole machine 200g;

· In-plane multi-angle puncture and out-of-plane center puncture, puncture enhancement;

access1

Handheld ultrasound scanner application of vascular access

1. Preoperative evaluation:

Amain handheld ultrasound scanner can understand the inner diameter of the blood vessel, the shape of the tube wall, whether there is thrombosis, calcification, arterial blood flow velocity, the dilation and patency of the vein, the position of the vein distance skin, and whether it is easy to puncture, etc., to provide more useful information for selecting the appropriate blood vessel and the surgical site. 

access2

Preoperative evaluation of fistula placement

access3

Internal diameter and distance from skin of cephalic vein

access4

Automatic measurement of radial blood flow

2. Positioning in tube and monitoring after tube placement:

Sidoco high-frequency small line array can accurately locate the position and depth of the vein, select the best injection Angle, observe the relationship with the adjacent artery to avoid mispuncture. At the same time, it has the functions of in-plane multi-angle puncture and out-of-plane center puncture, puncture enhancement, real-time display of needle tip position, and improve the success rate of catheterization.

access5

Puncture location of hemodialysis center in Department of Nephrology, Xuhui Center

access5

3. Postoperative monitoring:

Fistula maturity (anastomotic patency and changes in vascular diameter, velocity, and flow rate) was monitored, and internal complications (phlebotomatous dilatation, thrombosis, plaque formation, stenosis, occlusion, and pseudoaneurysm formation) were examined.

access7 access8