Quick Details
X- ray High voltage generator | |
standard output power:5.6kW | |
mA range:10-100mA | |
Tube voltage range:40-125kV | |
mAs range :0.1-200mAs | |
Load time range:0.002s~4s | |
High voltage transformer structure:The power frequency |
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
Online Portable Digital X-ray System AMPX07
1.X- ray High voltage generator | |
1.1 | standard output power:5.6kW |
1.2 | mA range:10-100mA |
1.3 | Tube voltage range:40-125kV |
1.4 | mAs range :0.1-200mAs |
1.5 | Load time range:0.002s~4s |
1.6 | High voltage transformer structure:The power frequency |
Online Portable Digital X-ray System AMPX07
2.X-ray tube | |
2.1 | Focus range:0.6/1.8mm |
2.2 | Anode types: fixed anode |
2.3 | The maximum voltage:125kV |
2.4 | Anode angle 15° |
2.5 | The inherent filtration:0.6mm Al/75kV |
3. Collimator | |
3.1 | The inherent filtration:1 mm Al /70 kV; |
3.2 | Collimator is equipped with LED lights(Bright 30S are automatically extinguished) |
3.3 | Collimator is built into measuring ruler |
Online Portable Digital X-ray System AMPX07
4. The tube bracket structure | |
4.1 | The Collimator of the measuring range: 150 ~ 2000mm |
4.2 | Telescopic Arm Length Range:450㎜~1860㎜ |
4.3 | Tube Tilting Angle:±180° |
Online Portable Digital X-ray System AMPX07
5. Detector | |
5.1 | WIFI connection ,silicon ,whole panel technology |
5.2 | Detector valid exposure size :30.72cm×24.43cm |
5.3 | Pixel size:120 µm |
5.4 | The effective camera size of the detector:10×12inch |
5.5 | Gathering matrix: ≥2560×2048pixels; |
5.6 | Spatial resolution≥4.2lp/mm |
5.7 | Pixel gray level:≥16bit |
5.8 | Detector cooling mode: natural cooling |
Online Portable Digital X-ray System AMPX07
6. Digital image workstation | ||
6.1 | CPU frequency:CORE i3 | |
6.2 | Memory capacity:4GB | |
6.3 | Hard drive capacity :500 GB | |
6.4 | 64 bit Windows operation system |
Online Portable Digital X-ray System AMPX07
7. Image acquisition software | |
7.1 | Patient registration: acquisition, find the patient data, to prepare for the photography |
7.2 | Images display, image analysis, processing and output |
7.3 | Data management: managing patient data, leading in, leading out , batch file, etc in accordance with DICOM3.0 |
7.4 | System diagnosis: monitoring system status, diagnosis of the system fault |
Online Portable Digital X-ray System AMPX07
8. Battery | |
8.1.1 | Power supply way |
8.1.2 | Lithium battery supply |
8.1.3 | The rated capacity:32.4V |
8.2 | Battery capacity: More than 100 exposures, (Exposure conditions: 50kV,80mA,20ms ) |
8.3 | Dual power supply,exposure under either wall current or lithium battery |
8.4 | Maximum charging 4 hours |
8.5 | The standby time is not less than 7 hours |
8.6 | Can support hand switch and remote control exposure |
Online Portable Digital X-ray System AMPX07
9. The machine parameters | |
9.1 | Appearance size |
9.1.1 | Whole machine width:240 mm |
9.1.2 | Whole machine length::440 mm |
9.1.3 | Whole machine height:236 mm |
9.2 | Whole weight :18kg |
10. External interface | |
10.1 | Wireless network data transmission(WIFI) |
10.2 | Choose a chest rack |
10.3 | The selection of moving flat bed |
Online Portable Digital X-ray System AMPX07
11. Aftersale service | |
11.1 | The machine warranty 1 year |
11.2 | Provide complete operation manual 1 set |
11.3 | Provide site application and service training |
11.4 | Free service hot line |
12. copyright certificate | |
12.1 | Utility model: a kind of medical product damping rotation axis |
12.2 | Appearance patent: portable digital X-ray machine |
12.3 | Software copyright: baolun technology portable X-ray machine embedded system software |
AM TEAM picture
Leave Your Message:
Write your message here and send it to us.