Quick Details
Function: 1.Display: 12.1” color TFT screen, high resolution: 800×600 dpi; 2.6 Parameters: Standard – 5-lead ECG/HR, NIBP, SPO2, Temp., Resp., PR; Optional – 3/12-lead ECG, single/double IBP, double Temp. Sun Tech NIBP, Masimo/Nellcor Spo2, ETCO2,BIS,CO; 3.Patient Range: Suitable for Adult, Pediatric, Neonate; 4.Multi-display interface: Standard, Large font, Trend Coexist, OxyCRG dynamic, 7 full ECG waveforms; 5.Language: Built-in 8 language for choose (English, Chinese, Turkish, Spanish, French, Russian, German, Italian); 6.Review: Maximum 720h tabular and graphic trends of all parameters, 1000NIBP records and 200 alarm event; 7.Battery: Built-in 2 hours rechargeable lithium battery, and battery volume display. 4 hours rechargeable lithium battery (optional); 8.Network: TCP/IP networking platform, connect with central monitoring system. Wifi central monitoring system (optional).
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
Patient monitor | monitor medical AMMP14
Function: 1.Display: 12.1” color TFT screen, high resolution: 800×600 dpi; 2.6 Parameters: Standard – 5-lead ECG/HR, NIBP, SPO2, Temp., Resp., PR; Optional – 3/12-lead ECG, single/double IBP, double Temp. Sun Tech NIBP, Masimo/Nellcor Spo2, ETCO2,BIS,CO; 3.Patient Range: Suitable for Adult, Pediatric, Neonate; 4.Multi-display interface: Standard, Large font, Trend Coexist, OxyCRG dynamic, 7 full ECG waveforms; 5.Language: Built-in 8 language for choose (English, Chinese, Turkish, Spanish, French, Russian, German, Italian); 6.Review: Maximum 720h tabular and graphic trends of all parameters, 1000NIBP records and 200 alarm event; 7.Battery: Built-in 2 hours rechargeable lithium battery, and battery volume display. 4 hours rechargeable lithium battery (optional); 8.Network: TCP/IP networking platform, connect with central monitoring system. Wifi central monitoring system (optional).
Patient monitor | monitor medical AMMP14
Feature: 1.Advance patient Manage: gender, full name, ID no., room no., bed no., weight, height, blood type, paced or not, remakes; 2.Multi-parameter board: Separated parameter board, main board, ECG board, SPO2 board, and NIBP board are independent; 3.Interface: Color, layout of each parameters can be set up by user need, bed to bed view display(optional); 4.Fanless: Use special fanless cooling technology in the device to provide users quiet environment; 5.Standby: Unique standby mode for energy saving and suspend monitoring; 6.Time delay: Time delay switch-off function to save data when monitor turn off suddenly; 9.Easy software update: Users can update monitor software by themselves; 10.Analysis: Real time S-T segment analysis, and 20 type arrhythmic analysis; SpO2 Pitch Tone Variation, Drug Dose Calculation and Hemodynamic Calculations; 11.Storage: external SD card slot enables memory extension(optional); 12.Data transfer: USB port to allow to transfer patient data to a PC (optional); 13.Special SINNOR F-6 Spo2 technology: which is as correct as Nellcor spo2 but cheaper than it(optional); 14.Resistance to interference : Efficient resistance to interference of defibrillator and HF knife; 15.Other optional: Touch Screen, Printer, Wall amount, VGA connect Optional: Touch Screen, Printer, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, ETCO2, Sun Tech NIBP, Wall mount, VGA, Wifi
Patient monitor | monitor medical AMMP14
Performance Specifications
Display | 12.1”color TFT |
Rolling and refreshing waveform display | |
Resolution: 800×600 | |
Multi display selectable including: | |
Standard display | |
Large-font display | |
Trend coexist display | |
OxyCRG dynamic view display | |
7 full ECG waveforms display | |
Bed-to-bed view display(optional) | |
Trace | 9 waveforms (7 ECG, 1 SPO2 and 1 RESP) |
Sweep speed:6.25mm/s, 12.5mm/s,25mm/s,50mm/s | |
Indicator | Power/battery indicator light |
QRS beep and alarm sound | |
Battery | Rechargeable lithium battery, 12v/4AH |
Max.24 hour for charging, 2 hours for continue working | |
Trend | Parameter graphic and tabular trends: |
5s/piece, 8 hours; | |
1min/piece,168 hours(24hour×7days) | |
5min/piece, 1000 hours. | |
Storage | NIBP: 1000 groups |
Alarm: 200 groups | |
SD card external storage (optional) | |
Alarm | User-adjustable High, Medium and Low limits 3-level |
Audible and visual alarm | |
Networking | Connected to central monitoring system |
TCP/IP netting platform | |
Wifi connector (optional) | |
Recorder | Build-in, thermal array |
Plethysmogram caveform:2 /3 channels | |
Record mode: manual, on alarm, time-defined | |
Recording width: 50mm | |
Printing speed: 50mm/s | |
Recording type | Frozen waveform record |
NIBP recall record | |
Trend table record | |
Alarm record | |
Fixed -time record |
Patient monitor | monitor medical AMMP14
Standard parameter
ECG |
Lead mode: 5 –lead(R, L, F, N, C) (3/12 lead ECG for optional) |
Lead selection: I, II, III, avR, avL, avF, V |
Waveform: 3 and 7 channel selectable |
Gain selection: 0.5mm/mv,1mm/mv,2mm/mv |
Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s |
Heart rate range: Adult: 15~300bpm; |
Neonate/pediatric: 15~350bpm |
Accuracy: +1bpm or +1%, which is greater |
Resolution: 1bpm |
Filter: surgery mode: 1~20Hz |
Monitor model: 0.5~40Hz |
Diagnostic mode: 0.05~130Hz |
Scaling signal: 1mv, +3% |
Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation |
Alarm range: 15~350bpm |
S-T segment detection: |
Measurement range: 2.0mV~+2.0mV |
Alarm Range: -2.0mV~ +2.0mV |
Accuracy: -0.8mV ~+0.8Mv |
Error: +0.02Mv |
Arrhythmia analysis: YES |
SPO2 |
Measurement range: 0~100% |
Wave speed: 12.5mm/s;25mm/s |
Resolution: 1% |
Accuracy: +2% (70-100%); 0-69% unspecified |
Alarm range 0~100% |
Lower perfusion situation |
Pulse Rate(PR) |
Range: 20~300bpm |
Resolution: 1bpm |
Error: +1bpm or +2%, whichever is greater |
NIBP |
Method: Digital Automatic oscillometric |
Operation mode : Manual/Automatic |
Auto measurement time: Adjustable (1~720min) |
(1,2,3,4,5,10,15,30,60,90,120,240,480,720min) |
Measurement Unit: mmHg/Kpa selectable |
Measurement types: Systolic, Diastolic, Mean |
Measurement Range: |
Range of Systolic pressure: Adult: 40~270mmHg |
Pediatric: 40~220mmHg |
Neonate: 40~135mmHg |
Range of mean pressure: Adult: 20~235mmHg |
Pediatric: 20~165mmHg |
Neonate: 20~110mmHg |
Range of diastolic pressure: Adult: 10~215mmHg |
Pediatric: 10~150mmHg |
Neonate: 10~100mmHg |
Over-pressure protection: Double safety protection |
Resolution: 1 mmHg |
Alarm: Systolic, Diastolic, and Mean |
RESPIRATION |
Method: RA-LL impedance |
Measurement range: Adult: 7~120rpm; |
Neonate/Pediatric: 7~150rpm |
Apnea alarm: YES, 10~40s |
Resolution: 1rpm |
Accuracy: +2rpm |
TEMPERATURE |
Compatible probe: YSI or CYF |
Measurement range: 5~50℃ |
Resolution: 0.1℃ |
Accuracy: +0.1℃ |
Refreshing time: about 1 |
Average measuring time: <10s |
Others Safety: Safety level: Class I, type CF Dimension and Weight Dimension: 28*42*48cm G.W: <6.5KS Operation Environment Temperature: Working 0~+40℃ Transportation and storage –20~+60℃ Humidity: working≤85% Transportation and storage≤93% Power: AC 100-240, 50/60Hz Accessories supplies 1. 5 lead ECG cable 1set 2. Adult Spo2 probe 1set 3. Adult NIBP Cuff and extension tube 1set 4. Temp probe 1set 5. Ground connecting liner 1set 6. ECG Chest electrode (10pcs/pack) 1pack 7.2200mA lithium battery 1PCS
AM TEAM picture
AM Certificate
AM Medical cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods arrive destination safely and quickly.