Professional China Dr X-Ray - AM-500 Digital Mammography System portable X-ray Mammography machine – Amain Detail:
Product Description
AR-500 Digital Mammography System portable X-ray Mammography machine
1. Application A mammogram is a special, low-dose X-ray technique used to take a picture of the breast, detecting and diagnosing
any abnormal lumps or masses in breast tissue. It is one of the best tools for the early identification of breast cancer. With
early identification, breast cancer can be cured while in the first stage, and recovery is more likely.
any abnormal lumps or masses in breast tissue. It is one of the best tools for the early identification of breast cancer. With
early identification, breast cancer can be cured while in the first stage, and recovery is more likely.
Specification
Item
|
Parameter
|
Remark
|
X-ray Generator
|
Generator Type: High Frequency Inverter 80kHz
Input Power: Single phase 220VAC, 50/60Hz Radiographic Ratings: Large Focal Point 20-35kV/10-510mAs Small Focal Point 20-35kV/10-100mAs Power Rating: 6.2kVA |
Self-developed and world advanced all-solid-state high frequency high voltage x-ray generator
|
X-ray Tube
|
Focal Spot Size: Dual Focus 0.1/ 0.3mm
Target Material: Molybdenum (Mo) Port Material: Beryllium (Be) High-speed anode drive: 2800 /10000rpm Target angle:10°/16° Anode Heat Storage: 210kJ (300kHU) Anode Cooling: Air cooling Filtration: Mo(0.03mm), Al(0.5mm) |
Model:IAE C339V
China tube for optional |
Radiographic Stand
|
C-ARM: Vertical Movement: 590mm
Center of electricrotating C-arm Automaticreturn function by one key Rotations Degree: +90°~-90° Automatically released after the exposure pressure settingsdisplay Compression flexible, stepless speed. Max. pressure: 200N Max. travel: 150mm SID: 650mm |
Electric Isocentricrotating
|
Flat Panel Detector
|
Detector material: Amorphous silicon
Effective coverage of detector: 18x24cm Pixel matrix: 3072×1944 Limit of spatial resolution: 6.0Lp/mm DQE value: 70% dynamic range: 14bit digital output pixel size: 75μm High voltage Synchronizer trigger: BNC Output: Camera Link or Ethernet Working condition: 10℃-40℃ storage environment: -10℃-50℃ |
China Flat Panel Detector
24x30cm for optional |
Bucky housing and movement device
|
Size: 374*304*65mm
Stepless speed regulating range: 0~6cm/s Movement range: 0.5~2cm Grid Size: 24x30cm Grid ratio: 5:1 Grid density: 30lp/cm Focal distance: 650mm |
|
Image acquisition workstation
|
CPU≥Intel Core Duo 2.60GHz
Hardware≥250G high speed Hardware Memory≥2G Display card≥512MB high brightness high-contrast LCD,1280*1024 Pixel resolution Network interface Work-list DICOM3.0 transmission 100/1000 Gigabit Ethernet Software Imaging software packageDMOC V1.0 |
Configuration including Diagnose digital workstation
5M medical monitor for optional |
Others
|
Line Voltage
220Vac±10%@25A,Single phase |
110V for optional
|
Product detail pictures:
Related Product Guide:
Well-run equipment, specialist income crew, and better after-sales services; We're also a unified major family, anyone stay with the organization value "unification, determination, tolerance" forProfessional China Dr X-Ray - AM-500 Digital Mammography System portable X-ray Mammography machine – Amain, The product will supply to all over the world, such as: Washington, Surabaya, Jeddah, Qualified R&D engineer will be there for your consultation service and we will try our best to meet your requirements. So please feel free to contact us for inquiries. You'll be able to send us emails or call us for small business. Also you are able to come to our business by yourself to get further knowing of us. And we will surely give you the best quotation and after-sale service. We're ready to build stable and friendly relations with our merchants. To achieve mutual success, we will make our best efforts to build a solid co-operation and transparent communication work with our companions. Above all, we are here to welcome your inquiries for any of our goods and service.
By Olive from France - 2018.02.21 12:14
The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
By Bella from Uzbekistan - 2018.10.09 19:07
Leave Your Message:
Write your message here and send it to us.