Short Description:

Model No.: AMVP04

Weight: Net weight: Kg

Minimum Order Quantity: 1 Set Set/Sets

Supply Ability: 300 Sets per Year

Payment Terms: T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal


Product Detail

Product Tags

High precision occlusion pressure sensors design
Motor anti-reverse function
Freedom of choice between automatic primed and manual primed

Safe and reliable vet syringe pump AMVP04
Safe and reliable
1.1 Using double CPU design, reliable data transmission, safer syringe.
1.2 High precision occlusion pressure sensors design, 8 levels adjustable of sensitivity occlusion pressure.
1.3 Real-time self-testing,real-time self-testing when startup and during syringe process, ensure the safety of each component and each function, safer syringe.

202109122017267826
202109122017266290
202109122017262533
202109122017262786

1.4 Automatic switching between AC and DC power supply , battery backup time more than 9hours under double channel are using, ensure no interruption when no AC power supply or in moving condition.
1.5 Alarm prompt with sound, light and message, 8 adjustable level of alarm volume.
1.6 Dynamic pressure value display,and real-time detect occlusion pressure status.
1.7 Various alarm, avoid the suddenly accidents during infusion process.
1.8 Motor anti-reverse function, avoid preventing upstream absolutely.
1.9 10000 event log, which reduce doctor-patient disputes and promote harmony between doctors and patients.

2. User friendly
2.1 Numeric keypad input, very user friendly.
2.2 Screen 3.5 inch big brightness LCD, display visually rich content and intuitive.
2.3 As the ATM easy operation menu, that is according people operation hobbits.
2.4 No need to open the battery door when maintain, easy to maintain.
2.5 Claw push rod, easily to install the syringe.
2.6 Freedom of choice between automatic primed and manual primed, displaying the purge rate, accurately knows the total amount of purge volume.
2.7 Displaying the Increment, VIBI, Total Volume, Brand and Sets of Syringe, Mode, Battery Volume, Occlusion pressure value, the key parameters display clearly.
2.8 Empty settings, syringe will be stop when finish all the fluid inside the syringe, no need to set the VTBI again.

3. Deviation and effective
3.1 The deviation of all international standard IV set are within ±2% after calibration.
3.2 Pulse compensation technology, more precise injection.
3.3 Automatic calibration, able to calibrate different brand syringe, more precise syringe.
3.4 Able to store more than 25 brands of infusion sets, user friendly.
3.5 The position of alarm light is highlighted, visible in directions from a long distance.
3.6 Cannot use the new syringe without calibration, ensure the accuracy and safety of the syringe.
3.7 Able to auto-recognize such five different mode syringe , 5ml, 10ml, 20ml, 30ml, 50(60)ml , and save syringe deviation
automatically.

4. Advanced technology
4.1 Multiple syringe mode, such as the ml/h, d/min, bolus, drug mode, which are greatly facilitate the different users with usage habits.
4.2 Display 10 levels brightness adjustable, energy saving and environmental protection.
4.3 Both Chinese and English language are available for use by foreign doctors.
4.4 The install method can be rotated by 90 degrees, which is convenient to use in different environments.
4.5 It is can be modified that the alarm time of fluid near empty, remind the medical staff prepare to replace the liquid medicine in advance.
4.6 Channel sleep function when syringe stop, keep quiet of environment.
4.7 KVO parameter and KVO rate are adjustable from 0.1ml/h to 5ml/h, that ensure the blood vessels are unblocked, and the needle blood does not coagulate.

4.8 Can be transmitted the event log to PC with USB, information and system upgrade and maintenance.
4.9 Occlusion pressure release function, reducing the pain caused to patients after occlusion.
4.10 Password function, avoid the risk of system parameters being modified by irrelevant personnel.
4.11 The rate of micro mode is adjustable from 0.10 to 99.99, which avoid the incorrect input with high syringe rate.
4.12 The gear setting function of occlusion pressure deviation is suitable all of different brand syringe occlusion pressure question.

NO Item Technical Parameter
1 Injection Mode Constant Rate, Time mode, Drug Weight,
Micro, Sequential, Drug Library Mode
2 Syringe Size 5ml, 10ml, 20ml, 30ml, 50/60ml, auto recognition
3 Flow Rate Range 5ml: 0.10ml/h-60.00ml/h 10ml: 0.10ml/h-300.00ml/h
20ml: 0.10ml/h-400.00ml/h 30ml: 0.10ml/h-600.00ml/h
50/60ml: 0.10ml/h-1200.00ml/h
4 Flow Rate Increment 0.01ml/h
5 Preset Time 1s-99hr59min59s
6 Parameter Changed During Injection Support change of VTBI, flow rate during injection
7 Accuracy ≤±2%(±1% mechanical accuracy included)
8 Preset Volume(VTBI) 0.1~9999.99ml & empty
9 Accumulated Volume 0.00~999.99ml
10 Purge Rate 5ml: 30-60ml 10ml: 150-300ml 20ml: 200-400ml
30ml: 300-600ml 50/60ml: 600-1200ml
11 Bolus Rate 5ml: 0.10ml/h-60.00ml/h 10ml: 0.10ml/h-300.00ml/h
20ml: 0.10ml/h-400.00ml/h 30ml: 0.10ml/h-600.00ml/h
50/60ml: 0.10ml/h-1200.00ml/h
12 KVO 0.10-5.0ml/h adjustable
13 Occlusion Pressure 8 level adjustable, 20Kpa-140Kpa, dynamically
pressure value display.
14 Alarm Finished, near finished, near empty, empty, occlusion,syringe disconnected, no operation, parameter error,syringe size error,low battery,
battery lost, battery ran out, AC power lost, abnormal injection,communication error.
15 Syringe Management Preset 20 syringe brands, can add or edit the brand,accept all brands after calibration.
16 Display 3.5' TFT color LCD, 10 level brightness adjustable.
17 Power Supply AC power, AC:100V~240V, 50Hz/60Hz,≤25VA
18 Communication Port USB, RJ45 for future use, Ethernet Port
19 Syringe Size 5ml, 10ml, 20ml, 30ml, 50/60ml, auto recogintion
20 Battery Rechargeable Lithium battery, DC11.1V, 3000mAh,
operating time: ≥9h@5ml/h
21 Alarm Voice Standard Medical Alarm Voice with Mute function,
8 levels adjustable.
22 Event log 1000 event log, can be transmitted to PC with USB
23 Software Upgrade Upgrade the software with USB
24 Operation Environment Temperature: +5℃~+40℃, Relative humidity:20%~90%,
Atmospheric pressure:70~106Kpa
25 Classification Class II, Type CF, IPX4
26 Dimension Size: 275mm*145mm*160mm, Weight: 2.1KG
27 Other Function Double CPU, Password function, Multi Language,
Pressure Release function, 90°rotatable IV pole,
4 soft function key, key lock function, numeric keypad, Pause function etc.
28 Application Intravenous injection