Quick Details
- Type: Anesthesia Equipments & Accessories
- Brand Name: AM
- Model Number: AMGA06
- Place of Origin: China (Mainland)
- Scope of application: adult, child
Packaging & Delivery
Packaging Details: | standard export package |
---|---|
Delivery Detail: | within 13 workdays after payment |
Specifications
Selling Well AMGA06 Used In Hospital Surgical Operation Anesthesia Machine – Buy Anesthesia Machine,Operation Anesthesia Machine,Hospital Anesthesia Machine Product on MEDSINGLONG GLOBAL GROUP CO.,LIMITEDWe are professional supplier of all kind of respiratory equipment,medical anesthesia machine
1. Medical anesthesia machine
2. Vertical anesthesia equipment
3. Mobile anesthesia machine
4. Anesthesia gas machine
anesthesia machine price – AMGA06
Main body | High-strength engineering plastic rack, light,
beautiful and corrosion resistant |
|
Scope of application | adult, child | |
Gas source | O2: 0.27~0.55MPa N2O: 0.27~0.55MPa | |
Flow meter |
O2 : 0.1~1.0L/min 1.1~10L/min |
|
N20: 0.1~1.0L/min 1.1~10L/min | ||
O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off. |
||
Flow rate of rapid oxygen supply | 25~75L/min | |
Low oxygen pressure alarm (Oxygen Alarm) | There will be sound alarm when the oxygen
pressure < 0.2MPa |
|
Vaporizer (Vaporizer Definition and Vaporizer Construction) | it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available. | |
Respiratory circuit | working mode: all-close, semi-close, semi-open
APL: 0.5~7 kPa |
|
Respiratory Bellows | bellows for adults, tidal volume range:0~1500 ml
bellows for children, tidal volume range:0~300 ml anyone can be chosen for application as required by the customer |
|
Ventilator (Ventilator Definition and Ventilator Function) | ||
Display mode | high-definition 5.7” LCD display | |
Ventilation mode | IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH | |
Ventilation parameters | Tidal volume | 20~1500 ml |
Rate | 1~99 bpm | |
SIMV rate | 2~20 bpm | |
I:E | 4:1~1:8 | |
Inspiratory trigger pressure | -1.0~2.0 kPa | |
PEEP | 0~2.0 kPa | |
Pressure range | 1.0~6.0 kPa | |
SIGH | 1.5 times the inspiratory time
(70-150 adjustable)
|
|
Parameters for ventilation monitoring | tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure – time waveform, flow rate – time waveform,PEEP,inspiratory trigger pressure, Inspiratory platform, autonomous inspiratory rate, lung compliance, airway resistance, flow-volume loop, pressure-volume loop | |
Monitoring of oxygen concentration | (21%~100%) | |
Security Alarm System | ||
Oxygen Concentration alarm | upper limit setting range 21%~100%
low limit setting range 10%~80% |
|
Airway pressure alarm | upper limit setting range 0.3~6.0 kPa
low limit setting range 0.2~5.0 kPa |
|
Per-minute ventilation volume alarm | upper limit setting range 3.0~30L/min
low limit setting range 1.0~10L/min |
|
Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 2.5 kPa | |
Suffocation alarm | it will give sound and light alarm if there is no tidal volume input for 15 seconds | |
Power alarm | ||
Power | AC 220V±10% 50Hz±1Hz(UPS, Storage battery) | |
(Mechanical Arms) | ||
(End-expiratory CO2 monitoring)
Items within brackets are optional. |