Zvinotsanangurwa
Ratidza screen vet murwere monitor inotengeswa AMMP06
12.1 ″ ruvara TFT skrini
Multi-channel inoratidzira Big font interface ST uye arrhythmia kuongororwa Kuverengera kwedosi yezvinodhaka uye titration tafura OxyCRG ine simba yekuona inoratidzira Kufema kutarisa neapnea maaramu Ongororo yearamu, arrhythmia wongororo Ruzivo rwevarwere.Input Anti-defibrillation dhizaini NIBP pamusoro pekumanikidza kudzivirira Plug-in rechargeable bhatiri, AC / DC iripo.Inotsigira waya kana isina waya network.
AM vet murwere anotarisisa kutengeswa AMMP06 Unyanzvi Kutaurwa
ECG Lead Mode 5 Inotungamira (R, L, F, N, C kana RA, LA, LL, RL, V) Kutungamira sarudzo I, II, III, avR, avL, avF, V Wavef orm 2 ch Lead mode 3 Inotungamira ( R, L, F kana RA, LA, LL) Kusarudzwa kwemutungamiri I, II, III, Wave fomu 1 ch Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, auto HR uye Alarm Range Vakuru 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpm Kururama ±1% kana±1bpm, iri hombe Resolution 1 bpm Sensitivity > 200 (uVp-p) Differential Input Impedance > 5 MΩ CMRR Monitor > 105 dB 5B Operation > Diagnod 8B dB Electrode offset inogona ± 300mV Leakage Current < 10 uA Baseline Recovery < 3 S Mushure meDefi.ECG Signal Range ± 8 m V ( Vp-p ) Bandwidth Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz Calibration Signal 1 (mVp-p), Kururama: 5% ST Segment Monitoring Range Measure -20 uye Alarm Measure. ~ +2.0 mV ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,Alarm Inowanikwa,Ongororo Inowanikwa Yekufema Nzira RF(RA- LL) Differential Input Impedance > 2.5 MΩ Measuring Impedance Range 0.3~3 Ω Base line Impedance Range 200~4 KΩ Bandwidth 0.1~2.5Hz Resp.Chiyero chekuyera neAlarm Range Vakuru 0 ~ 120 Brpm Neo/Ped 0 ~ 150 Brpm Resolution 1 Brpm Kururamisa ±2 Brpm Apnea Alarm 10 ~ 40 SNIBP Method Oscillometric Mode Manual, Auto, STAT Measuring Interval muAUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min) Measuring Period 5 Min STATl 40 ~ 240 bpm Alarm Type SYS, DIA, ZVINOREVA Kuyeresa nearamu mhando yeAdult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg ZVINOREVA 20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 200 mmHg ~100 mmHg ~150 mmHg ~150 mmHg ~ 150 mmHg DIA 151 mmHg DIA 151 Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg ZVINOREVA 20 ~ 110 mmHg Resolution 1mmHg Kururama Kukuru Kureva kukanganisa ± 5mmHg Maximum Standard kutsauka ± 8mmHg Overpressure Dziviriro Adult Mode 297±3 mmHg4 Mode ± 3 mmHg4 ± 3 mmHg4Hg2Hg ± 3 mmHg2HG Kuyera Rane 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 1 % Kururama 70% ~ 100% 2 % 0% ~ 69% isina kutaurwa Actualization intervalabout 1 Sec.Alarm Kunonoka 10 Sec.Pulse Rate Measuring and Alarm Range 20 ~ 300 bpm Resolution 1bpm Yakarurama ±3bpm TEMP Channel 2 Kuyera uye Alarm Range0 ~ 50 ℃ Resolution 0.1 ℃ Kururama ±0.2 ℃ Actualization intervalabo.Avhareji Yenguva Constant < 10 Sec.IBP Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Kuyera uye alarm range ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP-10 ~ 40 mmHg P1 / P2-10 ~ 300 mmHg Press Sensor Sensitivity 5 uV/V/mmHg Impedance 300-3000Ω Resolution 1 mmHg Kururamisa ±2% kana 1mmHg inova yakakura Actualization interval nezve 1 secretaryStandard: ECG, Kufema, NIBP, SpO2, Pulse Rate, Temperature Optional: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder