Top Suppliers Immuno Fluorescence - AW-1A CE approved Medical Neonatal Radiant Infant Warmer – Amain Detail:
Product Description
AW-1A CE approved Hospital Movable Types Baby Medical Neonatal Radiant Infant Warmer Price
Features
Three modes: pre-warm, manual and automatic
Set temperature and skin temperature display separately
Anti-explosion micro crystal quartz for radiation source
Self – testing function, various failure alarms by audible and visual
APGAR timer to record therapy time
Convenient X-ray cassette tray under infant mattress
Heater head can be adjusted ± 90° horizontally
Inclination of infant bed is adjustable
LED observe light angle is adjustable
Transparent protector can be folded down, with two infusion seals
RS232 connector
Three modes: pre-warm, manual and automatic
Set temperature and skin temperature display separately
Anti-explosion micro crystal quartz for radiation source
Self – testing function, various failure alarms by audible and visual
APGAR timer to record therapy time
Convenient X-ray cassette tray under infant mattress
Heater head can be adjusted ± 90° horizontally
Inclination of infant bed is adjustable
LED observe light angle is adjustable
Transparent protector can be folded down, with two infusion seals
RS232 connector
Standard Configuration
Main body (including the Radiant source, Control system, Infant bed, Bracket), X-ray cassette, Observe light, I.V. pole, Skin
temperature sensor, Tray, Mattress, Transparent protector, Castors, Drawers
Optional Functions
Low pressure aspirator
LED phototherapy unit
Built-in infant resuscitator
Oxygen supply system
Electric Elevator
Specification
Power supply
|
AC110/220V, 60/50Hz
|
||||||
Power input
|
1000VA
|
||||||
Environment temperature
|
18℃~30℃
|
||||||
Environment relative humidity
|
30%~75%
|
||||||
Atmospheric Pressure
|
700~1060hpa
|
||||||
Environment air velocity of flow
|
<0.3m/s
|
||||||
Skin Temperature control range
|
32℃~38℃
|
||||||
Skin temperature control accuracy
|
≤0.5℃
|
||||||
Skin temperature sensor accuracy
|
±0.3℃
|
||||||
Mattress temperature uniformity
|
<2℃
|
||||||
Infant Bed tilt angle
|
±10°
|
||||||
LED observation light function
|
3W
|
||||||
Warm-up time(from 25℃)
|
<30min
|
||||||
Heater head horizontal
|
±90°
|
||||||
Distance from heater to mattress
|
80cm
|
||||||
Mattress size
|
67cm*54cm
|
||||||
Timer range
|
0~99h59min
|
Product detail pictures:
Related Product Guide:
We love an incredibly fantastic standing amid our consumers for our superb item high quality, aggressive rate and also the finest assistance forTop Suppliers Immuno Fluorescence - AW-1A CE approved Medical Neonatal Radiant Infant Warmer – Amain, The product will supply to all over the world, such as: French, Georgia, Mumbai, Our solutions have national accreditation standards for experienced, premium quality goods, affordable value, was welcomed by people around the globe. Our products will continue to increase in the order and look forward to cooperation with you, Truly must any of people goods be of interest to you, make sure you letus know. We're likely to be delighted to give you a quotation up on receipt of one's in depth specs.
By Sally from Hanover - 2018.10.01 14:14
It is really lucky to meet such a good supplier, this is our most satisfied cooperation, I think we will work again!
By Johnny from Lisbon - 2017.06.29 18:55
Leave Your Message:
Write your message here and send it to us.