Iinkcukacha eziKhawulezayo
1)SpO2 umboniso wexabiso
2) Umboniso wexabiso lokubetha, umboniso wegrafu yebha
3) Umboniso we-wave wave
4) Imo yokubonisa ingatshintshwa
5) Ukukhanya kwesikrini kunokutshintshwa
Ukupakishwa kunye nokuhanjiswa
Iinkcukacha zokupakisha:Iphakheji yokuthumela ngaphandle eqhelekileyo Iinkcukacha zokuziswa: phakathi kweentsuku zokusebenza ezi-7-10 emva kokufunyanwa kwentlawulo |
Iinkcukacha
Eyona oximeter ye-pulse fingertip CMS50D
Intshayelelo
Umgaqo weCMS50D Pulse Oximeter umi ngolu hlobo lulandelayo: I-Photoelectric Oxyhemoglobin Inspection Technology yamkelwa ngokuhambelana neCapacity Pulse Scanning & Recording Technology, i-Pulse Oximeter ingasetyenziselwa ukulinganisa i-pulse saturation kunye nesantya se-pulse ngomnwe.
Imveliso ifanelekile ukuba isetyenziswe kwintsapho, isibhedlele, ibha ye-oxygen, ukhathalelo lwempilo yoluntu, ukunakekelwa ngokomzimba kwimidlalo (Inokusetyenziswa ngaphambi okanye emva kokwenza imidlalo, kwaye akukhuthazwa ukusebenzisa isixhobo ngexesha lenkqubo yokuba nemidlalo) kunye njl.
Eyona oximeter ye-pulse fingertip CMS50D
Iimpawu eziphambili
1)SpO2 umboniso wexabiso
2) Umboniso wexabiso lokubetha, umboniso wegrafu yebha
3) Umboniso we-wave wave
4) Imo yokubonisa ingatshintshwa
5) Ukukhanya kwesikrini kunokutshintshwa
6)I-low-voltage isalathiso: isalathisi se-voltage ephantsi sibonakala ngaphambi kokuba sisebenze ngokungaqhelekanga ngenxa ye-voltage ephantsi, Ukucima ngokuzenzekelayo umsebenzi: xa isixhobo siphantsi kojongano lokulinganisa.iyakucima ngokuzenzekelayo kwimizuzwana emi-5 ukuba umnwe uyawa ngaphandle kophando
7) Ifomati yokubonisa inokugcinwa emva kokucima kombane
Eyona oximeter ye-pulse fingertip CMS50D
Ukusebenza okuphambili
1) Imowudi yokubonisa: 0.96" Isiboniso esinemibala emibini (blue and yellow)
2) Uluhlu lokuMeta lwe-SpO2:0%~100%, (isisombululo yi-1%).
Ukuchaneka:70%~100%:±2%,Ngaphantsi kwama-70% akuchazwanga.
3) Uluhlu lokuMeta lwePR:30bpm ~250bpm, (isisombululo ngu-1bpm)
Ukuchaneka: ± 2bpm okanye ± 2% (khetha enkulu)
I-4) Umlinganiselo wokuSebenza kwiMeko yokuzaliswa okubuthathaka: i-SpO2 kunye nesantya se-pulse sinokuboniswa ngokuchanekileyo xa umlinganiselo wokuzaliswa kwe-pulse ngu-0.4%.Imposiso ye-SpO2 yi-±4%, impazamo yesantya se-pulse yi-±2 bpm okanye ±2% (khetha enkulu).
5) Ukumelana nokukhanya okujikelezileyo: Ukutenxa phakathi kwexabiso elilinganiswe kwimeko yokukhanya okwenziwe ngumntu okanye ukukhanya kwendalo yangaphakathi kunye negumbi elimnyama lingaphantsi kwe ± 1%
6) Ukusetyenziswa kwamandla: ngaphantsi kwe-30mA
7) Umbane: DC 2.6V - 3.6V
8) Ukunikezelwa kwamandla: 1.5V (ubungakanani beAAA) iibhetri zealkaline × 2
9) Iyure yokusebenza kwebhetri: Iibhetri ezimbini zinokusebenza rhoqo iiyure ezingama-20, inani lethiyori ziiyure ezingama-36.
10) Uhlobo loKhuseleko: Ibhetri yangaphakathi, Uhlobo lwe-BF