Isixhobo se-Innovo pulse oximeter AMXY37

Inkcazelo emfutshane:

Igama lemveliso:Isixhobo se-Innovo pulse oximeter AMXY37
Ixabiso langoku:

Inombolo yoMzekelo:AMXY37
Ubunzima:Ubunzima obububo: Kg
Ubuncinane boMyinge weodolo:1 Seti Iseti/Iiseti
Ubunakho bokubonelela:Iiseti ezingama-300 ngonyaka
Immimiselo yokuhlawula:T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal


Iinkcukacha zeMveliso

Iithegi zeMveliso

Iinkcukacha eziKhawulezayo

Idityaniswe ne Spo2 probe kunye nemodyuli yokubonisa
Incinci ngomthamo, ilula ngobunzima kwaye ilungele ukuthwala
Ukusebenza kwemveliso kulula, ukusetyenziswa kwamandla aphantsi
SpO2umboniso wexabiso

Ukupakishwa kunye nokuhanjiswa

Iinkcukacha zokupakisha:Iphakheji yokuthumela ngaphandle eqhelekileyo
Iinkcukacha zokuziswa: phakathi kweentsuku zokusebenza ezi-7-10 emva kokufunyanwa kwentlawulo

Iinkcukacha

Isixhobo se-Innovo pulse oximeter AMXY37

*Idityaniswe ne Spo2 probe kunye nemodyuli yokubonisa
*Incinci ngevolumu, ilula ngobunzima kwaye ilungele ukuthwala
*Ukusebenza kwemveliso kulula, ukusetyenziswa kwamandla aphantsi
*SpO2umboniso wexabiso

Isixhobo se-Innovo pulse oximeter AMXY37
*Umboniso wexabiso lokubetha, umboniso wegrafu yebha
*Umboniso we-wave wave
*Imo yokubonisa inokutshintshwa
*Ukukhanya kwesikrini kunokutshintshwa
*Isalathisi sevoltage ephantsi: isalathisi sevoltage esezantsi sivela phambi kokuba sisebenze ngendlela engaqhelekanga kwi-low-voltage
*Cima ngokuzenzekelayo umsebenzi: xa isixhobo siphantsi kojongano lokulinganisa.iyakucima ngokuzenzekelayo kwimizuzwana emi-5 ukuba umnwe uyawa ngaphandle kophando
*Ifomati yokubonisa inokugcinwa emva kokucima kombane

Isixhobo se-Innovo pulse oximeter AMXY37Ukusebenza okuphambili

Imowudi yokubonisa: 0.96"Umboniso we-OLED wemibala emibini (bhlowu natyheli)
Isisombululo seSkrini: 128 * 64
SpO2Uluhlu lokulinganisa: 0% ~ 100%, (isisombululo yi-1%).
Ukuchaneka: 70% ~ 100%: +/-2% ,Ngaphantsi kwe-70% engachazwanga.
Uluhlu lokuMeta lwePR: 30bpm~250bpm, (isisombululo ngu-1bpm)
Ukuchaneka: +/-2bpm okanye +/-2% (khetha enkulu)
Umlinganiselo wokuSebenza kwiMeko yokuZalisa ebuthathaka:
SpO2kunye nesantya se-pulse sinokuboniswa ngokuchanekileyo xa i-pulse-filling ratio yi-0.4%.SpO2imposiso ngu +/-4%, impazamo yezinga lokubetha ngu +/-2 bpm okanye +/-2% (khetha enkulu).
Ukuchasana nokuKhanya okuNgqongileyo: Ukutenxa phakathi kwexabiso elilinganiswe kwimeko yokukhanya okwenziwe ngumntu okanye ukukhanya kwendalo yangaphakathi kunye negumbi elimnyama lingaphantsi kwe +/-1%.
Ukusetyenziswa kwamandla: ngaphantsi kwe-30mA

Umbane: DC 3.0V
Ubonelelo lwamandla: 1.5V (ubungakanani beAAA) iibhetri zealkaline * 2
Iyure yokuSebenza kwebhetri : Elona xesha lincinci lomsebenzi liqhubekayo ziiyure ezingama-20, inani lethiyori ziiyure ezingama-36.
Uhlobo loKhuseleko: Ibhetri yangaphakathi, Uhlobo lwe-BF

Isixhobo se-Innovo pulse oximeter AMXY37Izincedisi

Thengisa ngokomgangatho:
*Intambo ejingayo
* Incwadi yomsebenzisi

UbunguMzimba
Ubungakanani: 57(L) * 31(W) * 32(H) mm
Ubunzima: Malunga ne-50g (kunye neebhetri)

Isixhobo se-Innovo pulse oximeter AMXY37Isiqinisekiso

Ipasile i-FDA kunye ne-CE


  • Ngaphambili:
  • Okulandelayo:

  • Shiya uMyalezo Wakho:

    Bhala umyalezo wakho apha kwaye uwuthumele kuthi.

    Shiya uMyalezo Wakho:

    Bhala umyalezo wakho apha kwaye uwuthumele kuthi.