Iinkcukacha eziKhawulezayo
Idityaniswe ne Spo2 probe kunye nemodyuli yokubonisa
Incinci ngomthamo, ilula ngobunzima kwaye ilungele ukuthwala
Ukusebenza kwemveliso kulula, ukusetyenziswa kwamandla aphantsi
SpO2umboniso wexabiso
Ukupakishwa kunye nokuhanjiswa
Iinkcukacha zokupakisha:Iphakheji yokuthumela ngaphandle eqhelekileyo Iinkcukacha zokuziswa: phakathi kweentsuku zokusebenza ezi-7-10 emva kokufunyanwa kwentlawulo |
Iinkcukacha
Isixhobo se-Innovo pulse oximeter AMXY37
*Idityaniswe ne Spo2 probe kunye nemodyuli yokubonisa
*Incinci ngevolumu, ilula ngobunzima kwaye ilungele ukuthwala
*Ukusebenza kwemveliso kulula, ukusetyenziswa kwamandla aphantsi
*SpO2umboniso wexabiso
Isixhobo se-Innovo pulse oximeter AMXY37
*Umboniso wexabiso lokubetha, umboniso wegrafu yebha
*Umboniso we-wave wave
*Imo yokubonisa inokutshintshwa
*Ukukhanya kwesikrini kunokutshintshwa
*Isalathisi sevoltage ephantsi: isalathisi sevoltage esezantsi sivela phambi kokuba sisebenze ngendlela engaqhelekanga kwi-low-voltage
*Cima ngokuzenzekelayo umsebenzi: xa isixhobo siphantsi kojongano lokulinganisa.iyakucima ngokuzenzekelayo kwimizuzwana emi-5 ukuba umnwe uyawa ngaphandle kophando
*Ifomati yokubonisa inokugcinwa emva kokucima kombane
Isixhobo se-Innovo pulse oximeter AMXY37Ukusebenza okuphambili Imowudi yokubonisa: 0.96"Umboniso we-OLED wemibala emibini (bhlowu natyheli)
Isisombululo seSkrini: 128 * 64
SpO2Uluhlu lokulinganisa: 0% ~ 100%, (isisombululo yi-1%).
Ukuchaneka: 70% ~ 100%: +/-2% ,Ngaphantsi kwe-70% engachazwanga.
Uluhlu lokuMeta lwePR: 30bpm~250bpm, (isisombululo ngu-1bpm)
Ukuchaneka: +/-2bpm okanye +/-2% (khetha enkulu)
Umlinganiselo wokuSebenza kwiMeko yokuZalisa ebuthathaka:
SpO2kunye nesantya se-pulse sinokuboniswa ngokuchanekileyo xa i-pulse-filling ratio yi-0.4%.SpO2imposiso ngu +/-4%, impazamo yezinga lokubetha ngu +/-2 bpm okanye +/-2% (khetha enkulu).
Ukuchasana nokuKhanya okuNgqongileyo: Ukutenxa phakathi kwexabiso elilinganiswe kwimeko yokukhanya okwenziwe ngumntu okanye ukukhanya kwendalo yangaphakathi kunye negumbi elimnyama lingaphantsi kwe +/-1%.
Ukusetyenziswa kwamandla: ngaphantsi kwe-30mA
Isisombululo seSkrini: 128 * 64
SpO2Uluhlu lokulinganisa: 0% ~ 100%, (isisombululo yi-1%).
Ukuchaneka: 70% ~ 100%: +/-2% ,Ngaphantsi kwe-70% engachazwanga.
Uluhlu lokuMeta lwePR: 30bpm~250bpm, (isisombululo ngu-1bpm)
Ukuchaneka: +/-2bpm okanye +/-2% (khetha enkulu)
Umlinganiselo wokuSebenza kwiMeko yokuZalisa ebuthathaka:
SpO2kunye nesantya se-pulse sinokuboniswa ngokuchanekileyo xa i-pulse-filling ratio yi-0.4%.SpO2imposiso ngu +/-4%, impazamo yezinga lokubetha ngu +/-2 bpm okanye +/-2% (khetha enkulu).
Ukuchasana nokuKhanya okuNgqongileyo: Ukutenxa phakathi kwexabiso elilinganiswe kwimeko yokukhanya okwenziwe ngumntu okanye ukukhanya kwendalo yangaphakathi kunye negumbi elimnyama lingaphantsi kwe +/-1%.
Ukusetyenziswa kwamandla: ngaphantsi kwe-30mA
Umbane: DC 3.0V
Ubonelelo lwamandla: 1.5V (ubungakanani beAAA) iibhetri zealkaline * 2
Iyure yokuSebenza kwebhetri : Elona xesha lincinci lomsebenzi liqhubekayo ziiyure ezingama-20, inani lethiyori ziiyure ezingama-36.
Uhlobo loKhuseleko: Ibhetri yangaphakathi, Uhlobo lwe-BF
Isixhobo se-Innovo pulse oximeter AMXY37Izincedisi Thengisa ngokomgangatho:
*Intambo ejingayo
* Incwadi yomsebenzisi
*Intambo ejingayo
* Incwadi yomsebenzisi
UbunguMzimba
Ubungakanani: 57(L) * 31(W) * 32(H) mm
Ubunzima: Malunga ne-50g (kunye neebhetri)