H7c82f9e798154899b6bc46decf88f25eO
H9d9045b0ce4646d188c00edb75c42b9ek

I-AM Advanced Anesthesia Ventilator AMGA15 iyathengiswa

Inkcazelo emfutshane:

Igama lemveliso:I-Advanced Anesthesia Ventilator ithengiswa-AMGA15
Ixabiso langoku: US $ 500-1307 / Seti

Inombolo yoMzekelo:AMGA15
Ubunzima:Ubunzima obububo:76 Kg
Ubuncinane boMyinge weodolo:1 Seti Iseti/Iiseti
Ukubonelela ngezakhono:IiSeti ezingama-300 ngonyaka
Immimiselo yokuhlawula:T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal


Iinkcukacha zeMveliso

Iithegi zeMveliso

Iinkcukacha eziKhawulezayo

Lo matshini we-anesthesia uqukethe iyunithi ephambili, i-anesthetic vaporizer, i-flow meter, i-respirator ye-anesthesia kunye nenkqubo yesekethe yokuphefumula.

Ukupakishwa kunye nokuhanjiswa

Iinkcukacha zokupakisha:Iphakheji yokuthumela ngaphandle eqhelekileyo
Iinkcukacha zokuziswa: phakathi kweentsuku zokusebenza ezi-7-10 emva kokufunyanwa kwentlawulo

Iinkcukacha

I-Advanced Anesthesia Ventilator ithengiswa-AMGA15

 

AMUmatshini weAnesthesia Ventilator-AMGA15Isishwankathelo

Lo mshini we-AMGA15 Anesthesia sisixhobo esibalulekileyo sokuthomalalisa iintlungu kwigumbi lokusebenza.Umsebenzi wayo kukubonelela nge-oxygen kunye ne-agent ye-anesthetic kwisigulane esifuna ukuhamba ngokusebenza kwe-anesthesia kunye nokulawulwa kwe-ventilation.Lo matshini we-anesthesia wenzelwe ukusetyenziswa kubantwana kunye nabantu abadala abanobunzima bomzimba obunzima kune-10kg. Lo mshini we-AMGA15 Anesthesia uxhotyiswe ngokuchanekileyo Umphunga we-anesthetic ozinikeleyo kunye nesixhobo sokhuseleko sokuthintela i-cyanosis kunye nenkqubo ye-alam eyimfuneko.Ngexesha le-anesthesia, imisebenzi yokuphefumula yesigulane inokulawulwa ngokusebenzisa i-microcomputer elawulwa yi-pneumatic elawulwa ngombane i-synchronizing anesthesia respirator.Inxalenye yokudibanisa yomatshini wonke i-interface eqhelekileyo.Isithako sesoda ekalika esinamandla kakhulu nesinomthamo omkhulu sinciphisa ukuphefumla kwakhona kwekharbon dayoksayidi sisigulana.    

Iimeko zokusebenza zeAMGA15Umtshini weAnesthesiae:

———Iqondo lobushushu bokuhlala: 10 ~ 40 ℃ ;———Ukufuma okuhambelanayo: akukho ngaphezu kwe-80 %;——–Uxinzelelo lomoya: 860 hPa ~ 1060 hPa.——–Amandla afunekayo: ~220-240/60V, 50V, 50V, Hz. I-40VA, ukuba isekelwe kakuhle.---Imfuno yomthombo womoya: i-oksijeni yonyango kunye negesi ehlekayo kunye noxinzelelo olulinganisiweyo olusuka kwi-0.3 ukuya kwi-0.5MPa. Ingqalelo: umbane we-AC osetyenziselwa umatshini we-anesthesia kufuneka ubekwe kakuhle. Qaphela: i-anesthesia Umatshini osetyenzisiweyo kufuneka ube ne-carbon dioxide esweni ehambelana ne-ISO 9918: 1993, i-oksijini esweni ehambelana ne-ISO 7767: 1997 kunye nomthamo wegesi ephelelwayo ehambelana ne-51.101.4.2 yesiXhobo soMbane sezoNyango iSigaba II: IiMfuno eziZodwa zoKhuseleko noKhuseleko Ukusebenza okusisiseko kweNkqubo ye-Anesthesia. I-Anesthesia Ventilator etshiphu i-AMGA15 Iimpawu zoLwakhiwo kunye neMigaqo yokuSebenzaLo matshini we-anesthesia uqukethe iyunithi ephambili, i-anesthetic vaporizer, i-flow meter, i-anesthesia respirator kunye nenkqubo yesekethe yokuphefumla.

Eyona Ventilator yeAnesthesia ithengiswayo-AMGA15 yobuchwephesha

I-1 Imodi yokusebenza: i-circulatory ivaliwe, i-semi-closed kunye ne-semi-open.2 Imfuno yegesi: i-oksijeni yonyango kunye negesi ehlekayo kunye noxinzelelo olusuka kwi-0.3MPa ukuya kwi-0.5 MPa.3 Impazamo enkulu yesixhobo sokuvavanya uxinzelelo akufanele idlule ± (4 I-% yokufundwa kwesikali esipheleleyo + i-8% yokufunda okuyinyani) .4 I-oksijini kunye negesi ehlekayo, umlawuli okhethekileyo woxinzelelo kunye ne-valve yokukhusela iya kunikwa.Uxinzelelo lokukhupha lwevalve yokhuseleko akufanele lube ngaphezulu kwe-6 kPa.5 Uluhlu olubonisa uluhlu lwe-oksijini kunye negesi ehlekayo imitha yokuhamba kwegesi: 0.1 L/min ~ 10 L/min. I-100%, ukuchaneka kwesikali kufuneka kube ngaphakathi kwe-±10%yexabiso elibonisiweyo.6.Umitha wokuhamba uxhotyiswe nge-oxygen-laughing gas device control proportional control.Xa i-oxygen concentration kwi-gas exutywe i-N2O / O2 ihanjiswe ngumshini we-anesthesia ayikho ngaphantsi kwe-20% (V / V) okanye i-FiO2 ingaphantsi kwe-20%, umatshini uya kukhupha i-analarm.7. Xa uxinzelelo lwe-oksijini yomshini we-anesthesia yi-0.20MPa ± 0.05MPa, umatshini uphakamisa i-alarm ye-gas sourcepressure ephantsi okuyiyona nto ibaluleke kakhulu, kwaye ivala igesi ehlekayo ehanjiswa kwi-gas outlet eqhelekileyo.8.I-Oxygen Flush: 25~75 L/Min;9.Uluhlu lohlengahlengiso lwegesi ye-anesthetic ye-vaporizer: 0~5%, impazamo ehambelanayo ± 20%.10.Uxinzelelo lokukhupha i-valve yokhuseleko lwesiphaluka sokuphefumula alukho ngaphezu kwe-6 kPa.11.I-Anesthesia ventilator11.1 Indlela yokuphefumla:IPPV,SIPPV,Manu11.2 Amaxesha okuPhumla:4~40bpm11.3 I/E Ratio:1:1.5~1:411.4 Tidal Volume:50~1500mL11.5 Ptr:-10~10hPa11. Ukungena komoya okulawulwayo kunye nexesha lokutshintsha umoya oncediswayo: 6s11.7 Ubuninzi boxinzelelo lokhuseleko: ≤ 12.5 kPa.11.8 Uluhlu lwemida yoxinzelelo: 1~6 kPa11.9 I-alamu yoxinzelelo lomoya: uluhlu lohlengahlengiso lomda we-alamu ephezulu: 0.3kPa ~ 6 kPa, impazamo evumelekileyo ± I-0.2 kPa, okanye ± 15% (nokuba yeyiphi na enkulu), umatshini kufuneka ngokukhawuleza aphakamise i-alamu yezinga eliphezulu xa uxinzelelo lwe-airway lunyuka kwi-alamu;umda we-alamu ophantsi usuka kwi-0.2 ukuya kwi-5 kPa kwaye impazamo evumelekileyo yi-± 0.2 kPa okanye ± 15% (nokuba yeyiphi na enkulu) ukuya kwi-15s.3.11.10 i-alamu yevolumu ye-Tidal: umda ophezulu we-alamu usuka kwi-50 ukuya kwi-2000ml, impazamo evumelekileyo yi-± 20%, uluhlu lohlengahlengiso lomda we-alamu ophantsi ngu-0 ~ 1800ml, impazamo evumelekileyo yi-± 20% kunye umatshini kufuneka uphakamise i-alam yenqanaba eliphakathi.3.11.11 Umthamo we-ventilation ephantsi komda we-alamu: uluhlu lohlengahlengiso luyi-0 ~ 12 L / min, kwaye impazamo evumelekileyo yi-± 20%. Umthamo we-ventilation ephezulu ye-alamu imiselwe ukuba ibe yi-25 L / min, impazamo evumelekileyo yi-± 20 % kwaye umatshini kufuneka uphakamise i-alam yomgangatho ophakathi.3.11.12 I-alam yempazamo yokubonelela ngombane: umatshini kufuneka unike i-alam evakalayo xa umbane ucima kwaye i-alam kufuneka ihlale ngaphezu kwe-120s.3.11.13 Ixesha lokuthulisa isignali ye-alam evakalayo kufuneka libe ngaphantsi kwee-120s.Ubume be-alam akufunekanga ukuba yenziwe ukuba ingasebenzi kwaye isignali ye-alam ebonwayo mayingaphazanyiswa.3.11.14 Ibhetri yexesha likaxakeka kufuneka ibe yibhetri yeasidi ekhokelayo enombane olinganisiweyo ophumayo we-DC 12V.Ubude bexesha lokusebenza kwesiphefumli sokuthomalalisa esiqhutywa yibhetri kufuneka sibe ngaphezu kwe-60min.  

Balisa intengiso eshushu kunye nomatshini ophathwayo we-anesthesia ophathwayo

AMGA07PLUS AMPA01 I-AMVM14
AMGA15 AMVM06 AMN31

AM TEAM umfanekiso

 

 


  • Ngaphambili:
  • Okulandelayo:

  • Shiya uMyalezo Wakho:

    Bhala umyalezo wakho apha kwaye uwuthumele kuthi.

    Shiya uMyalezo Wakho:

    Bhala umyalezo wakho apha kwaye uwuthumele kuthi.