Iinkcukacha eziKhawulezayo
Iimpawu: i-Compound Imaging, i-Speckle Reduction Imaging, i-Tissue Harmonics imaging, i-4D, i-Automatic Image Optimization, i-Tissue Doppler, ukulungiswa komfanekiso, i-Multi-Beam, i-IMT, i-Trapezoidal imaging iBank database
Ukupakishwa kunye nokuhanjiswa
Iinkcukacha zokupakisha:Iphakheji yokuthumela ngaphandle eqhelekileyo Iinkcukacha zokuziswa: phakathi kweentsuku zokusebenza ezi-7-10 emva kokufunyanwa kwentlawulo |
Iinkcukacha
I-AMCU41 Umgangatho ophezulu we-4D umbala we-Doppler inkqubo ye-ultrasound
UMZEKELO | AMCU41 3.0 INKQUBO |
Iimpawu zekhompyuter | Inkqubo yokuSebenza eFakelwe kwiWindows (CN, EN ulwimi) 19'' imonitha yezonyango (1280*1024)+10.4'' imonitha yokuchukumisa Intel i5 iprosesa 4G RAM 120G SSD + 500G HDD |
Ubunzima / Ubungakanani | Akwaziwa |
Iindlela zokufanekisa | 2D, 3D, 4D, Color/PW/CW/Power/Directional Color Power Doppler, I-Tissue Doppler, i-M-Mode yoMbala, i-Free Steering (I-Anatomical) Imo ye-M |
Iimbonakalo | Umfanekiso odibeneyo, Umfanekiso wokuNcitshiswa kwamabala, I-Tissue Harmonics imaging, 4D, ULungiselelo loMfanekiso oluzenzekelayo, I-Doppler yezicubu, Ukulungiswa komfanekiso, i-Multi-Beam, i-IMT, i-Trapezoidal imaging I-iBank database |
Iindlela ze-DICOM | Gcina, Shicilela, Uluhlu lokuSebenza, UkuZibophelela kokuGcina, iiNgxelo ezakhiweyo |
Iinketho zokuThumela ngaphandle | I-DICOM, i-Ethernet, iJPG/BMP/PNG, iAVI, Ukugcinwa kweNethiwekhi, intonga yeMemori ye-USB. USB DVD/CD+R(W) |
Igalelo/Imveliso | VGA, 2 USB Ports, Ethernet, Dicom, Izithethi eyakhelwe-ngaphakathi |
Iintlobo zeTransducer | Iconvex, iLinear, iSector Phased, iMicro Convex, 4D Volume Convex, Endocavity, Veterinary linear |
Usetyenziso | Isisu, i-OB/GYN, iUrology, iCardiac, iVascular, Amacandelo amancinci, aBantwana, i-MSK |
Probe Ports | 4 Iyasebenza |
Cine Memory | > 10 imizuzwana, 750frames |
I-AMCU41 Umgangatho ophezulu we-4D umbala we-Doppler inkqubo ye-ultrasound
1.Umsebenzi oPhezulu weKlinikhi: i.Isekwe kwimenyu yenkqubo yokusebenza ye-Windows XP, kunye ne-VGA 10.4 intshi ye-LED ye-touch screen yokusebenza imenyu, i-lauguages yesiNgesi / yaseTshayina yokhetho, i-screen layout inokuhlelwa, ukwandisa okanye ukunciphisa ubuninzi bemenyu okanye ukutshintsha indawo yokubonisa. njengoko abasebenzisi becela, ekulungeleyo ukuba oogqirha babone ukusebenza kwangoku.ii.One key automatic optimization (AUTO): Oogqirha bafuna nje ukucofa isitshixo se-AUTO, inkqubo iya kulungelelanisa ngokuzenzekelayo kwaye ikhulise iiparameters zokucinga ezahlukeneyo ngokomqondiso we-echo wombutho owahlukileyo, njengale nkqubo ye-ultrasound ingasetyenziselwa ukwandisa ngokuzenzekelayo i-spectrum. kwaye ulungelelanise isiseko kunye nesantya sokuphindaphinda i-pulse, ngokukhawuleza ufumane imifanekiso eyanelisayo ye-ultrasound, yenza uhlengahlengiso lomfanekiso lube lula ngakumbi kwaye lukhawuleze, luphucule ukusebenza kakuhle kokuxilongwa kweklinikhi.iii.Ukusetwa kwangaphambili kweParameter (impawu zeempawu zombutho) : ugqirha unokwenza ezona parameters zibalaseleyo zesixhobo ngokwazo kwinkqubo ebekwe kwangaphambili ngokweempawu zokucinga zemibutho eyahlukeneyo, njengesibindi, isibindi, izintso, isibeleko, i-ovary njalo njalo. iintlobo ze-viscera, kwi-ultrasound yesiqhelo yokuxilonga, ukuxilonga imibutho eyahlukeneyo, oogqirha kufuneka nje bakhethe isitshixo esisetwe kwangaphambili, inkqubo iya kuba lulungelelwaniso oluzenzekelayo ngokupheleleyo kwimeko yokuxilongwa kwe-ultrasonic yombutho, akufuneki ukuba ulungelelanise kwakhona, uya kufumana okufanelekileyo. umfanekiso, onokuphucula ukusebenza kakuhle.iv.Iindlela ezimfutshane zokucwangcisa umsebenzi weparameter: amaqhosha amahlanu endlela ezimfutshane, abasebenzisi banokuchaza umsebenzi wokusetyenziswa kwamaqhosha amahlanu, isitshixo sokuqonda ukusebenza okukrelekrele, ukuphepha uhlengahlengiso lweparamitha yesixhobo, ukuphucula isantya sokuxilonga.v.Intelligence amplification function: inokwandisa nayiphi na indawo ye-ultrasonic yomdla, ibonwe ngokucacileyo ukuxilongwa, ukuphucula ukusebenza kakuhle kokuxilongwa kweklinikhi vi.Ubuchwephesha bokufihla umbala: kwimodi yombala, akufuneki ukuba uphume kwimodi yombala unokwenza umbala ufihliwe. , ivumela oogqirha ukuba baphumeze ngokukhawuleza ukuqwalaselwa komfanekiso wombala kunye nesakhiwo se-2D vii.RTSA real-time analysis spectrum function: Imowudi ye-D, (phantsi kwemowudi yokuskena) ingenza ngokuzenzekelayo i-envelope spectrum kwaye ibale i-PSV, EDV, AVp, AVm, ats, DT, RI , PI kunye nezinye iiparamitha ze-hemodynamic.viii.Khangela umsebenzi wefestile: ukuxilongwa komfanekiso ogciniweyo wangoku, gcina ukukhangela umfanekiso kwicala lasekhohlo lesikrini, uvumela oogqirha ukuba bakhangele nanini na, benze uthelekiso kunye nohlalutyo.I-ix.I-interface ye-Host inokujikeleza, kunye nekhibhodi edibeneyo kunye nokukhanya kwemvelaphi, inokufaka ulwazi lwesiTshayina / isiNgesi, iqonde i-man-machine interactive x.Inkqubo yokukhangela isibane sesibane: ukuhlalutya ngokuzenzekelayo izitshixo ezisebenzayo zangoku, ivumela oogqirha ukuba bazi ngokucacileyo umsebenzi wangoku, khokela ugqirha amanyathelo alandelayo ngesalathisi esinemibala emininzi.
I-AMCU41 Umgangatho ophezulu we-4D umbala we-Doppler inkqubo ye-ultrasound
I-2.Advanced Technology i-iAndidi ze-high frequency probe configuration, ububanzi be-probe frequency wide: 2-14 MHZ, i-high-frequency linear array probe frequency yi-14.0 MHZ, ubuninzi buyanelisa iimfuno zesicelo seklinikhi.ii.Uluhlu oluguquguqukayo lweSystem ukuya kuthi ga kwi-260 db, kubandakanywa ne-15-145 db ebonakalayo eguquguqukayo, ukuze ufumane ngokucacileyo kwaye ubeke isiseko semifanekiso ye-2D.iii.Ukusebenzisa iteknoloji ye-imaging ye-compound, isisombululo somfanekiso: i-longitudinal ≤1 mm, i-horizontal ≤ 0.5 mm, umfanekiso we-2D ulungile, ucacile, kulula ukufumana izilonda ezincinci zakuqala, ukunceda oogqirha ukuba baphucule ukuchaneka kokuxilongwa.iv.Ixhotyiswe ngokwandisa iteknoloji ye-pulse imaging, ukuphucula ukungena kunye nokuchasana kwemifanekiso, i-probe scanning deep ≥ 360 mm, ilungele izigulane ezityebileyo kunye nezigulane ezingelula ukufumana imifanekiso emihle.v.Idityaniswe nokwandisa iteknoloji yokucinga yecandelo, iprobe yesisu: ukuskena i-Angle ≥ 105 degrees, intracavitary probe: scanning Angle≥160 degrees, i-probe scanning I-Angle inokuqwalasela iimeko ezibanzi ze-viscera ethile, ukubonisa ulwazi oluninzi lomfanekiso, ngakumbi ukujonga. i-viscera enkulu.I-vi.Linear array probe imaging trapezoidal imaging kunye ne-2D beam deflection technology: i-viscera inokujongwa ngoluhlu olubanzi lweemeko ezithile kwaye iphephe ngokufanelekileyo ikhava yangaphambili, ibonise ngokucacileyo i-viscera ngasemva kwezicubu zokudubula okunamandla, vumela oogqirha ukuba bahlolisise umfanekiso kwiindawo ezikhethekileyo. ekunzima ukuyifumana.I-vii.Tissue imaging harmonic (THI): inkqubo inokucoca itekhnoloji ye-harmonic; iteknoloji ye-harmonic yesigaba sokubuyela umva; Ukwandisa iteknoloji ye-harmonic ye-pulse, iintlobo ezintathu zeteknoloji ye-harmonic ukuqonda i-imaging ye-harmonic ye-tissue ecocekileyo, ukufumana umgangatho ophezulu womfanekiso we-harmonic wezicubu, ngexesha elifanayo, isisu, i-frequency ephezulu, i-harmonic imaging probes inemisebenzi efana ne-cavity, i-harmonic 2 ixesha lokuphindaphinda okuhlengahlengiswayo, imodeli ye-harmonic iintlobo ezintathu zeenketho, umda ophezulu ukwanelisa iimfuno zeentlobo zeklinikhi viii.Nge-adaptive speckle yokunciphisa iteknoloji, yenza umda ocacileyo phakathi kwezicubu kunye namanqanaba olawulo ukuphucula umfanekiso, bonisa utshintsho olupheleleyo lwe-contour eyinkimbinkimbi ye-pathological, kulula ukuhlukanisa utshintsho lokuqala lwe-pathological, inceda oogqirha ukuba baphucule ukuchaneka kokuxilonga, ukulungelelanisa izigulane ezinzima zokungenelela kunye nonyango lwe-ultrasonic, kunye nezinye iinjongo ezikhethekileyo. I-ix.color doppler imaging system enombala ogcweleyo wedijithali wokuhamba kwegazi, i-directional energy doppler imaging features, apho i-PW pulse wave doppler kunye ne-CW eqhubekayo ye-doppler yamaza,≤1 mm/s, umlinganiselo we-PWD ophezulu wokuhamba kwegazi ≧ I-12300 mm/s, i-CW ephezulu yesantya sokuhamba kwegazi yokulinganisa ≥33200 mm/s, kunye nobubanzi besampulu yegazi kunye nobubanzi bendawo: ububanzi 0.5-40 mm, yinkqubo ye-ultrasound ye-Doppler yombala ophezulu womgangatho ophezulu.x.Idityaniswe real-time dynamic density beam scanning (HDB) technology with high sensitivity (HSCFM) blood flow imaging technology, yenza izixhobo ezinovakalelo oluphezulu kakhulu, ulwazi ngalunye lokuhamba kwegazi lunokubanjwa ngokuchanekileyo xi.Ngombala wobuchwephesha bokuphambuka kwegazi : ukunqanda into engavakaliyo phakathi kolwalathiso lokuhamba kwegazi kunye ne-ultrasound beam pertical flow, uvakalelo lokuhamba kwegazi luphezulu, kunye neentlobo ezahlukeneyo zokuphambuka iinketho ze-Angle.I-xii.Ixesha langempela leeyunithi ezintathu ezihambelanayo: i-2D kunye ne-doppler yombala, i-spectral doppler inokuboniswa ngexesha elifanayo, kulula ukuba oogqirha bahlalutye umahluko.I-AMCU41 High-End 4D umbala we-Doppler inkqubo ye-ultrasound ye-3.I-System Configuration i.Imodi yokubonisa: B, BB, M, BM, 4B, BC, BCD, imaging anoramic, yandisa imbono yokucinga, i-imaging, i-trapezoidal composite imaging (SCI) imodeli ukuya B, indawo, ipateni yetshathi yokuhamba kwegazi yombala, imo yegrafu yamandla ombala, imowudi yegrafu yamandla, imowudi ye-bipolar tissue harmonic imaging, i-PW pulsed wave doppler imaging, i-CW i-wave wave doppler imaging, i-3 d / 4 d imaging mode ii. Umfanekiso ogcweleyo wedijithali we-2D grey-scale imaging iv.Umbala othe ngqo weDoppler i-doppler imaging v.PW pulsed wave doppler imaging vi.CW ingqindisiso eqhubekayo yedoppler imaging vii.Isithuba somfanekiso wekhompawundi viii.Umfanekiso obanzi wescene (Ukhetho) ix.Phezulu isisombululo se-compound imaging x.THI, ekhoyo kwiconvex,linear, cardiac and trans-vaginal probes itekhnoloji yohlengahlengiso xv.Ixesha langempela lesithathu lolungelelwaniso xvi.PIP imowudi yomfanekiso wengqondo yengqondo xvii.Imowudi yokucinga ye-3D yexesha langempela: izixhobo ezixhotyiswe ngokwakhiwa kwe-4d (3d) iipakethi zemodyuli zemodyuli yexesha langempela, abasebenzisi banokusebenzisa ezihambelanayo (ixesha langempela le-3d ) umthamo we-4d probe, ukufumana umsebenzi ogqibeleleyo womfanekiso we-4D.iphakheji ye-xviii.multi, ukongeza kwiphakheji yesoftware yokulinganisa ngokubanzi, enemithambo yeperipheral, i-gynecology kunye nokubelekisa, intliziyo, i-urologist, usana olusanda kuzalwa, utyando lwamathambo, njalo-njalo ukulinganisa kunye nohlalutyo lweepakethe ezikhethekileyo zokuhamba kwegazi, umda omkhulu uyanelisa iimfuno klinikhi.I-xix.built-in E - Inkqubo yolawulo lwegraphic COM: 560GB hard disk storage, editable ultrasound diagnostic report in Chinese/English, embedded ultrasonic diagnostic image kwingxelo, kunye nokugcinwa ngokuthe ngqo, ukuprinta, callback, umbuzo njalo njalo, ukutshisa eyakhelwe- kumqhubi weDVD kunye nojongano lwe-USB xx.display: i-intshi ezili-19 ze-LED zesisombululo esiphezulu bonisa xxi.multi probe iinketho: 1)Convex probe: 2.5-5.0MHz (Variable frequency, harmonic frequency ≥5 iintlobo), Probe scanning Angle of 20 ° ~ 85 °, ibonwayo kwaye iyahlengahlengiswa.2) Iprobe yomgca: 6.0-14.0MHz (i-Variable frequency, i-harmonic frequency ≥4 iintlobo), i-probe scanning kunye ne-trapezoidal imaging kunye ne-2D ye-beam deflection technology.3) Trans-vaginal probe: 5.0-9.0MHz (Variable frequency, frequency harmonic ≥2 iintlobo), Probe scanning Angle of 20 ° ~ 160 ° ebonakalayo kunye adjustable.4) Nge-real-time 3d (4d) iprobe yevolumu: 2.0-5.5 MHz, iintlobo ezi-4 ze-frequency adjustable.Uphononongo olunokhetho olunenqanaba loluhlu lwentliziyo: 2.0-5.5MHz, iintlobo ezi-5 zokuhlengahlengiswa.Intengiso eshushu Sonoscape