Awọn alaye kiakia
Plug-in batiri gbigba agbara, AC/DC wa.
Cardiotocography, ẹrọ ctg, idiyele ẹrọ ctg, idiyele ẹrọ ctg.
Iṣakojọpọ & Ifijiṣẹ
Alaye iṣakojọpọ: Apo okeere boṣewa Awọn alaye ifijiṣẹ: laarin awọn ọjọ iṣẹ 7-10 lẹhin gbigba isanwo |
Awọn pato
Iboju Fọwọkan Olona-Parameter Alaisan Atẹle AMMP09
12.1 "awọ TFT iboju ifọwọkan
Windows ara, Olona-ikanni àpapọ Big font ni wiwo ST ati arrhythmia onínọmbà Oògùn iwọn lilo isiro ati titration tabili OxyCRG ìmúdàgba view àpapọ Respiration monitoring pẹlu apnea awọn itaniji Atunwo Itaniji, arrhythmia awotẹlẹ alaisan info.Input Anti-defibrillation oniru NIBP lori titẹ Idaabobo Plug-ni batiri gbigba agbara, AC/DC wa.Okun atilẹyin tabi nẹtiwọki alailowaya.Cardiotocography, ẹrọ ctg, idiyele ẹrọ ctg, idiyele ẹrọ ctg. Gbigba imọ-ẹrọ Aiah (TM) ECG, ilodisi kikọlu, ni anfani lati gba ifihan agbara ECG ti ko lagbara kuro ninu kikọlu.Gbigba imọ-ẹrọ NIBP Surepeb (TM), wiwọn deede si alaisan titẹ ẹjẹ ti o ga ati alaisan titẹ ẹjẹ kekere.SP02 Nellcor (TM) OxiMax (TM) jẹ asiwaju agbaye SpO2 imọ-ẹrọ Nellcor (TM) OxiMax (TM) n pese iṣẹ ti o dara julọ, paapaa ni awọn ipo ibojuwo ti o nira ti perfusion kekere ati kikọlu ifihan agbara, pẹlu išipopada alaisan.ETCO2 Ṣe ifowosowopo pẹlu Respironics, Plug ati Play EtCO2 ibojuwo.CAPNOSTAT sensọ ojulowo fun iṣẹ ti o dara julọ ni ṣiṣe abojuto alaisan ti a fi sinu inu.Kekere, ti o tọ ati sensọ ojulowo iwuwo fẹẹrẹ n pese ibojuwo deede ati igbẹkẹle fun gbogbo awọn alaisan inu inu lati ọdọ awọn ọmọ tuntun si awọn agbalagba.Loflo sidestream sensọ fun abojuto alaisan ti kii ṣe intubated.Irọrun, sensọ CO2 iwapọ n pese ibojuwo deede ati igbẹkẹle ti agbalagba, awọn ọmọ ilera ati awọn alaisan ọmọ tuntun.Cardiotocography, ẹrọ ctg, idiyele ẹrọ ctg, idiyele ẹrọ ctg.Awọn Solusan Iṣagbesori pupọ Ipo Asiwaju ECG Awọn itọsọna 5 (R, L, F, N, C tabi RA, LA, LL, RL,V) Aṣayan adari I, II, III, avR, avL, avF, V Wave form 2 ch Ipo asiwaju 3 Awọn asiwaju (R, L, F tabi RA, LA, LL) Aṣayan asiwaju I, II, III, Wavef orm 1 ch Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto HR and Itaniji Ibiti Agbalagba 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpm Yiye ± 1% tabi ± 1bpm, eyiti o tobi ju Ipinnu 1 bpm Sensitivity> 200 (uVp-p) Imudaniloju Input Iyatọ> 5 MΩ CMRR Atẹle> 105 dB Isẹ> 105 dB Ayẹwo> 85 dB Electrode aiṣedeede o pọju ± 300mV Leakage Lọwọlọwọ <10 uA Imularada Ipilẹ <3 S Lẹhin Defi.Iwọn ifihan agbara ECG ± 8 m V ( Vp-p ) Iṣẹ abẹ bandiwidi 1 ~ 20 Hz Atẹle 0.5 ~ 40 Hz Aisan Aisan 0.05 ~ 130 Hz Calibration Signal 1 (mVp-p), Ipeye: 5% Iwọn Iwọn Abojuto Abala ST ati Itaniji -2.0 ~ +2.0 mV ARR wiwa Iru: ASYSTOLE, VFIB/VTAC, Tọkọtaya, BIGEMINY, TRIGEMINY, R ON T, VT>2, BRADY, MISSED BEATS, PNP, PNC, Itaniji Wa, Atunwo Wa Cardiotocography, ctg ẹrọ, ctg ẹrọ ctg ẹrọ iye owo.Ọna atẹgun Impedance laarin RF(RA-LL) Iyatọ Input Impedance > 2.5 MΩ Iwọn Iwọn Iwọn Imudaniloju 0.3 ~ 3 Ω Ipilẹ Ipilẹ Ipilẹ Ipilẹ 200 ~ 4 KΩ Bandwidth 0.1 ~ 2.5Hz Resp.Iwọn Iwọn ati Ibiti Itaniji Agbalagba 0 ~ 120 Brpm Neo/Ped 0 ~ 150 Brpm Ipinnu 1 Brpm Yiye ± 2 Brpm Itaniji Apnea 10 ~ 40 S Ọna NIBP Ilana Itọsọna Oscillometric, Aifọwọyi, Aarin Idiwọn STAT ni Ipo AUTO 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (min) Akoko wiwọn ni Ipo STAT 5 Min Oṣuwọn Pulse 40 ~ 240 bpm Iru itaniji SYS, DIA, MEAN Atẹle Alaisan Ọjọgbọn AMMP09 Iwọn ati ibiti itaniji Awọn ipo Agba SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Ipo Itọju Ẹdọ SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg DIA 10 ~ 150 mmHg 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg Ipinnu 1mmHg Ipeye Aṣiṣe Itumọ ti o pọju ±5mmHg Iyapa Iwọn to pọju ± 8mmHg Idaabobo Idaabobo Ipaju Ipo Agba 297± 3 mmHg Ọna itọju ọmọde ± 3 mmH 0 ~ 100 % Itaniji Ibiti 0 ~ 100 % Ipinnu 1 % Yiye 70% ~ 100% 2 % 0% ~ 69% Aifọwọsi Iṣeduro Aarin 1 iṣẹju-aaya.Idaduro Itaniji 10 iṣẹju-aaya.Iwọn Iwọn Pulse ati Ibiti Itaniji 20 ~ 300 bpm Ipinnu 1bpm Yiye ± 3bpm TEMP Channe 2 Iwọn ati Ibiti Itaniji 0 ~ 50 ℃ Ipinnu 0.1 ℃ Yiye ± 0.2 ℃ Imuse imuse nipa iṣẹju-aaya 1.Ibakan Akoko Aago <10 iṣẹju-aaya.IBP Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Iwọn wiwọn ati ibiti itaniji ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP-10 ~ 40 mmHg P1/P2-10 ~ 300 mmHg Tẹ Sensọ Sensitivity 5 uV/V/mmHg Impedance 300-3000Ω Ipinnu 1 mmHg Yiye ± 2% tabi 1mmHg eyiti o jẹ aarin imuse ti o tobi julọ nipa 1 akọwe Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature Optionally: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder AM TEAM aworan Iwe-ẹri AM AM Medical ṣe ifọwọsowọpọ pẹlu DHL, FEDEX, UPS, EMS, TNT, ati bẹbẹ lọ ile-iṣẹ sowo kariaye, jẹ ki awọn ẹru rẹ de opin irin ajo lailewu ati yarayara. Kaabọ si medicalequipment-msl.com, Ti o ba ni ibeere eyikeyi ninu atẹle Alaisan.Jọwọ lero free lati olubasọrọcindy@medicalequipment-msl.com