Uhlobo: 400ma ukuxilongwa x ray imishini-AMCX12
Igama Brand: AM
Inombolo yemodeli: AMCX12
Indawo yokuzalwa: China
I-Fluoroscopy Voltage: 45-110KV i-voltage eqhubekayo
Supply Amandla: 20KVA
I-Fluoroscopy Yamanje: 0.3-5mA imali eqhubekayo
Imvamisa yamandla okunikezela: 50Hz ± 1Hz
I-Radiography yamanje: 50-400mA shift
I-Radiography Voltage: 45-125KV i-voltage eqhubekayo
Isikhathi seRadiography: 0.03-5s23 shift
X-Ray tube Model: XD 51-20,40 /125
Ukupakisha Nokulethwa
Imininingwane yokupakisha : iphakheji yokuthekelisa esezingeni eliphindwe kabili
Imininingwane yokulethwa: zingakapheli izinsuku zokusebenza eziyi-7-10 ngemuva kokuthola inkokhelo
Imininingwane
Umshini we-fluoroscopy kanye ne-radiography
Umshini we-X Ray
ukuxilongwa kwe-x ray
Izici:
1) Ifakwe ithebula lokuxilonga eliphindwe kabili kanye namarubhu e-xray, i-tube voltage ingu-125kV, imali yeshubhu ingu-400mA, ibhuloho elilodwa eliqondile elihamba ngegagasi eligcwele.
2) Ukuvikelwa komthamo weshubhu ye-X-ray, ukuvikela ukuqalisa kwe-anode kanye nedivayisi yokuvikela umkhawulo wesikhathi we-radiograph isetshenziswa kancane indlela yokuziphatha, idivayisi ye-fluoroscopy computed time, i-xray tube overhot protecionare enikeziwe, qinisekisa ukuthi ishubhu le-xray lisebenza ngokuphepha isikhathi eside, kuthuthukisa ukunemba kwe-kV mA S.
3) Ububanzi obukhulu betafula lokuxilonga elijikelezayo, idivayisi ye-muliitem spotfilm ephathekayo, kulula ukuyisebenzisa, i-radiation-proof, qinisekisa ukusebenza kanye nokuhlolwa.
4) Ithebula le-radiography linganyakaza ngobude kanye ne-crossover, lingalayisha zonke izinhlobo zebhokisi elimnyama le-radiography, lisebenzise kalula futhi lihle.
5) Kusetshenziswa kuzo zonke izinhlobo zesibhedlela ukuze uthole i-radiography efana nomzimba ojwayelekile, ukuhlungwa kwe-beam, nesifuba.
Amapharamitha wobuchwepheshe:
Umnyango | Imingcele yezobuchwepheshe | |||
Ithebula lokulawula ijeneretha yamandla aphezulu kanye nokuguqulwa kwamandla kagesi aphezulu kuyahlangana | I-Fluoroscopy | Imali ye-tube | 0.3-5mA imali eqhubekayo | |
I-tube voltage | 45-110KV voltage okuqhubekayo | |||
I-Radiography | Imali ye-tube | 50-400mA shift | ||
I-tube voltage | 45-125KV voltage okuqhubekayo | |||
Isikhathi sokuchayeka | 0.03-5s23 shift | |||
Amandla | Amandla kagesi | 380V±10% | ||
Imvamisa | 50Hz±1Hz | |||
Amandla | ≥30KVA | |||
Ukumelana kwangaphakathi | ≤0.3Ω | |||
Ukuhlanganiswa kwe-X-ray | Uhlobo lwe-x-ray | XD51-20.40/125 | ||
Gxila | 1×1.2×2 ukugxila okukabili | |||
Isivinini sokuzungezisa esilinganiselwe se-anode | 2800r/min | |||
Idivayisi elinganiselwe ye-beam eshintshiwe | Ithebula lokuxilonga YS09D | Okuzenzakalelayo, inkambu yokubuka elungisiwe | ||
Ithebula le-Radiograph YS11S | Inkambu yokubuka elungiswe mathupha, ukukhanya≥100LX | |||
Ithebula lokuxilonga le-C15 | Zungezisa itafula | -15°~0°~90°okuzenzakalelayo | ||
Itafula elinyakazayo | Okuzenzakalelayo 700mm ibanga ezihambayo ubude | |||
Ibanga letafula eligxile | 400mm | |||
Phezulu kwetafula | 820 mm | |||
Idivayisi yefilimu ye-Spot | Ububanzi buhamba | Phezulu naphansi | 600mm | |
Kwesokunxele nakwesokudla | ± 100mm | |||
Phambili nangemuva | 300mm | |||
Indlela yokukhiya | Ukukhiya i-Electromagnetism | |||
Into ye-radiography | 5×7,8×10,10×12,11×14 | |||
Ithebula le-radiography ye-CDGI Multi function | Itafula elinyakazayo | Ubude | ± 600mm | Ukukhiya i-Electromagnetism |
Ngaphesheya | ± 120mm | |||
Igridi yokuhlunga insimbi yeselula | Ukuminyana kwegridi | 28L/cm | ||
Isilinganiso segridi | 81 | |||
Ibanga lokugxila | 100cm | |||
Ububanzi bokuhamba | ≥600mm | |||
Into ye-radiography | 5×7,8×10,10×12,11×14, | |||
12×15,14×14,14×17 | ||||
Ibanga ukusuka phezulu kuya kwifilimu | 75 mm | |||
Ukuphakama kombhede | 700mm | |||
Insika ehambayo | ±180°, ngo-90° orientation, ubude obuhambayo ≥1500mm | |||
I-tube ye-bulb | Zungezisa ingalo yesiphambano±180, khuphuka $ wehle ngo-1100mm |
Inketho
I-LSJ insika ye-radiography frame | Ububanzi bokwenyuka nokwehla | 1450 mm | |
Ibanga elincane ukusuka endaweni okugxilwe kuyo | 380mm | ||
Into ye-radiography | 8"*10" 10"*12" 11"*14"12"*15" | ||
14"*14" 14"*17" | |||
Indima yokuhlunga kwe-beam elungisiwe | Ukuminyana kwegridi | 40L/cm | |
Umsakazo wegridi | 10:01 | ||
Ibanga lokugxila | 180cm |