Imininingwane Esheshayo
- Izakhiwo: Imishini ye-X-ray Yezokwelapha Nezesekeli
- Igama lebrand: AM
- Inombolo Yemodeli: AMPX04
- Indawo Yomsuka: China (Mainland)
- umshini we-x-ray: uyaphatheka
- imvamisa ephezulu: 2.4KW
Ukupakisha Nokulethwa
Imininingwane Yokupakisha:Ukupakisha okujwayelekile kokuthekelisa okujwayelekileImininingwane yokulethwa: phakathi kwezinsuku eziyi-15-18 zokusebenza ngemuva kokuthola inkokhelo
Imininingwane
ifekthri ithengisa ngokuqondile umshini we-x-ray we-Fluoroscopy ongu-2.4KW - AMPX04
1.Umshini we-x-ray ophathwayo
2.Umshini we-x-ray ophathwa ngesandla
3.High frequency X-ray machine
《Ukwethulwa komshini we-x-ray》- Wake wezwa ngendaba yokutholwa kwe-X-ray?Yatholwa kanjani i-X-ray?Ungakwazi yini ukuthola okunye ukusetshenziswa komshini we-X-ray?…
Izici:
Ubukhulu.Isithombe se-x-ray tube (Liyini ithubhu le-x-ray?Ukwakhiwa kwe-x-ray tubeAmandla kagesi: 100kV/24mA
Ubukhulu.Isithombe se-x-ray tube current: 60mA
Ubukhulu.Okukhiphayo: 2.4kW
Isikhathi sokuvezwa: 0.008s ~ 3.33s
Ububanzi be-MAS: 0.5mAs ~ 160mAs ngokushintshana okungu-46
Ububanzi be-voltage: 40~100kV 2kV nokushintshashintsha okungu-31
Imvamisa enkulu: 30kHz
Ubukhulu.inkambu yokukhanya: ≤35CMX35CM @65CM SID
Okuncane.inkambu yokukhanya: ≤5CMX5CM @100CM SID
Usayizi wokugxila: 1.5mm
Amandla: 220V ± 10% isigaba esisodwa esishintshayo samanje nemvamisa engu-50Hz ± 1Hz
Ukumelana: ≤ 1.0 Ω
Amandla wamandla: ≥ 3.5kVA
Uhlobo lokuvikela ugesi: Ikilasi I, Uhlobo B
Isisindo: 18.6kg
2.4KW Fluoroscopy x-ray machine – AMPX04
1.Ihlanganiswe ne-high frequency kanye ne-high voltage generator, isistimu yokulawula eyinhloko, isistimu yekhompyutha ehlakaniphile, isibonisi sezinombolo kanye nedivayisi elinganiselwe ye-boam, iklanywe futhi yakhiwe ngokunembile nangokuhlangene, ngokuguquguqukayo kakhudlwana futhi isetshenziswa kabanzi.
2.Kusetshenziswa indlela yesiguquli esiphambene se-HF kanye nohlelo lokulungisa iluphu evaliwe olulawulwa ngekhompiyutha, kukhiqizwa ukuphuma kwamandla kagesi aphezulu okuzinzile futhi kutholakale izithombe zekhwalithi ephezulu.
3.Usebenzisa izinkinobho ze-KV nama-mAs ukulungisa amapharamitha ezithombe, uwabonise kuma-LED anokukhanya okuphezulu, izimo zokuvikela i-interlock zinqunywa isoftware, elungele ukuthi odokotela bayisebenze.
I-4.X-ray Tube ibekwe kusilinda somthofu esingavikela ngempumelelo ukuvuza kwe-gamma futhi ivikele imvelo nokuphepha kwabasebenzisi.
5.20 Izimo ze-radiographic zisethwe kusengaphambili futhi zingenziwa ngezifiso ngokuya ngezidingo zomsebenzisi.
6.Isikhathi sokuthwebula silawulwa yikhompuyutha, umsingathi uzobambezela ngokuzenzakalelayo imizuzwana eyi-10 ekupheleni kwesithombe esingalawula ngempumelelo isikhawu sokuthatha izithombe, sigweme ukugcwala ngokweqile futhi sizuze ukuvikeleka okuzenzakalelayo.
7.Umsebenzi wezithombe olawulwa ngesandla futhi olawulwa kude.
8.Isebenzisa ikhompuyutha ukuqapha imithombo yamaphutha, ikhompuyutha izonqamula konke okuphumayo, ibonise ikhodi yephutha futhi ibone izizathu zephutha uma iphutha livela.
9.Ifanele zonke izinhlobo zamakhasethi.
Ukusebenza kwesakhiwo:
1.I-Radiography ingaqalwa ngemva kokuthi kumiswe okokusebenza kwe-X-ray kuhlaka.
2.I-fuselage ye-X-ray apparatus imisiwe ohlakeni, ingazungeza kwesokunxele nakwesokudla ngokukhudlwana noma ngokulingana no-±90°, i-X-ray tube head ingazungezisa ku-90° okulula ukuyiveza ngama-engeli ahlukene.
3.Ingalo ingakwazi ukuya phezulu naphansi, ine-Servo-balance kanye nedivayisi yokuvala.
4.I-fuselage ye-X-ray apparatus inesisindo esingu-19Kg, ilungele ukuthwala.Uhlaka lunesisindo esingama-23 Kg, lukwazi ukuguquguquka kakhulu ukuhamba ezindaweni ezahlukene.
5.Ifreyimu ingahlakazwa futhi igoqwe ngokushesha, bese ifakwa esiqwini, engenza ukuphuma ucingo kube lula.
Isiqukathi sezinsimbi siyindlela eyengeziwe.
sebenzisa:
ephumayo i-saveorthopaedics esibhedlela izinga eliyisisekelo lokulungisa izinwele nokulungisa kabusha ucingo lwezimo eziphuthumayo lwe-ICU
Ukwelashwa komphakathi endaweni yasemaphandleni Ukwelashwa okujwayelekile kokwelashwa.