I-X-ray Generator | Uhlobo Lwegenerator: High Frequency Inverter 80kHz Amandla Okufaka: Isigaba esisodwa 220VAC, 50/60Hz Izilinganiso zeRadiographic: Iphoyinti Elikhulu Eligxilile 20-35kV/10-510mAs I-Focal Point encane engu-20-35kV/10-100mAs Isilinganiso samandla: 6.2kVA | Ijeneretha ye-x-ray eyakhiwe ngokuzithuthukisa I-All-solid-state high frequency high voltage x-ray |
X-ray Tube | I-Focal Spot Usayizi: Ukugxila Okukabili 0.1 / 0.3mm Into Eqondiwe: I-Molybdenum (Mo) I-Port Material: Beryllium (Be) Idrayivu ye-anode enesivinini esiphezulu: 2800 /10000rpm I-engeli eqondiwe: 10°/16° Isitoreji Sokushisa kwe-Anode: 210kJ (300kHU) Ukupholisa kwe-Anode: Ukuhlunga komoya okupholisa: Mo (0.03mm), Al (0.5mm) | Imodeli: IAE C339V |
I-Radiographic Stand | I-C-ARM: Ukunyakaza Okuqondile: 590mm Isikhungo se-C-arm ejikelezayo kagesi Umsebenzi wokubuyisela okuzenzakalelayo ngokhiye owodwa Idigri Yokuzungezisa: +90°~-90° Ikhishwe ngokuzenzakalelayo ngemva kokuboniswa kwezilungiselelo zengcindezi yokuchayeka Ukucindezela okuguquguqukayo, isivinini esingenasinyathelo. Ubukhulu.ingcindezi: 200N Ubukhulu.ukuhamba: 150mm Ukuphakama: 650 mm | Ukujikeleza kwe-Isocentric kagesi |
I-Flat Panel Detector | Izinto zomtshina: I-silicon ye-amorphous Ukumbozwa okusebenzayo komtshina: 24x30cm I-matrix yephikseli: 3072 × 1944 Umkhawulo wokulungiswa kwendawo: 6.0Lp/mm Ivelu ye-DQE: 70% Ibanga elinamandla: 14bit okukhiphayo kwedijithali Usayizi wephikseli: 75μm I-voltage ephezulu ye-Synchronizer trigger: Okukhiphayo kwe-BNC: Isixhumanisi Sekhamera noma i-Ethernet Isimo sokusebenza: 10 ℃-40 ℃ Indawo yokubeka: -10℃-50℃ | |
Indlu ye-Bucky kanye nedivayisi yokunyakaza | Usayizi: 374*304*65mm Ibanga lokulawula isivinini esingenasinyathelo: 0~6cm/s Ububanzi bokunyakaza: 0.5 ~ 2cm Usayizi wegridi: 24x30cm Isilinganiso segridi: 5:1 Ukuminyana kwegridi: 30lp/cm Ibanga lokugxila: 650mm | |
Indawo yokusebenza yokutholwa kwesithombe | CPU ≥ Intel Core Duo 2.60GHz Izingxenyekazi zekhompuyutha ≥ 250G Imemori Yekhompuyutha yejubane eliphezulu ≥ 2G Bonisa ikhadi ≥ 512MB Ukukhanya okuphezulu kwe-LCD enokugqama okuphezulu, i-1280*1024 pixel resolution Isixhumi esibonakalayo senethiwekhi Umsebenzi – uhlu Ukuhanjiswa kwe-DICOM 3.0 100/1000 Gigabit Ethernet Isoftware: Iphakheji yesoftware yokuthwebula i-DMOC V1.0 | Ukucushwa kufaka phakathi i-Diagnostic workstation yedijithali Imonitha yezokwelapha engu-2M ngokuzikhethela |
I-Voltage yomugqa | 220V ac±10%@25A,Isigaba esisodwa | 110V ngokuzikhethela |
Usayizi Wokupakisha | 2160*690*1150mm | |
GW | 350kg | |
NW | 35kg |
Isicelo somkhiqizo
I-mammogram iyindlela ekhethekile, enedosi ephansi ye-X-ray esetshenziselwa ukuthatha isithombe sebele, ukuthola kanye nokuxilonga noma yiziphi izigaxa ezingavamile noma uquqaba lwezicubu zebele.Kungelinye lamathuluzi angcono kakhulu okuhlonza umdlavuza webele kusenesikhathi.Ngokuhlonzwa kusenesikhathi, umdlavuza webele ungelapheka ngesikhathi usesigabeni sokuqala, futhi ukululama kungenzeka kakhulu.
Izici Zomkhiqizo
1. Yamukela ubuchwepheshe obukhethekile be-mammography flat panel imaging technology.2. Usayizi ogcwele we-digital mammography we-x-ray imaging.3.Unique yamukela yonke-solid-state high frequency high voltage generator.4.I-mammography ephephe kunazo zonke ku-voltage ephezulu.Kukhona ikhoyili yeX-ray eyakhelwe ngaphakathi emshinini wokusingathwa, izintambo zamandla kagesi aphezulu zingaphansi kuka-25cm.5.Indawo yokusebenza yokulawula ukutholwa kwesithombe se-Mammography, i-DICOM 3.0.6.I-Electric Isocentric ejikelezayo ye-C-arm enomsebenzi ohlukile ozenzakalelayo wokubuyela enkabeni.7.Ongakukhetha igridi ehambayo yesizukulwane sesithathu.8.Okuzenzakalelayo/okuzenzakalelayo/okuzenzakalelayo/ngemanuwali, izindlela ezintathu zokuchayeka ezinomusa.9.Idivayisi yokukhipha isithombe ozikhethela yona: iphrinta yefilimu yedijithali.10.Ingqikithi yezingcezu ezi-3 zosayizi omkhulu ogcwele umbala ogcwele wokuboniswa kwesikrini se-LCD, itafula lokusebenza 8 intshi yesikrini se-LCD ukhiye wokuthinta.11.Ukucindezelwa Okunethezekile: Uma izinga elithile lokucindezela lidingeka ku-radiography, ikuvumela ukuthi ucindezele ingcindezi efanele (kuze kufike ku-20kg) futhi ifakwe uhlelo lwe-MICOM Control's Soft-touch oluklanyelwe ukunciphisa ukungakhululeki kokuhlolwa ebangeni lokucindezela.I-Tissue Compression: Manual and Motorized (Max 20kg) / Compression Force and Thickness Data Display / Micro Control's Compression / Automatic Release