12.1″ isikrini se-TFT sombala
Ukupakisha Nokulethwa
Imininingwane yokupakisha:Iphakheji yokuthekelisa ejwayelekile Imininingwane yokulethwa: phakathi nezinsuku zokusebenza eziyi-7-10 ngemuva kokuthola inkokhelo |
Imininingwane
Bonisa isikrini sokuqapha kwesiguli sesiguli esithengiswayo AMMP06
12.1″ isikrini se-TFT sombala
Isibonisi samashaneli amaningi Isixhumi esibonakalayo sefonti enkulu ST kanye nokuhlaziywa kwe-arrhythmia Ukubalwa komthamo wezidakamizwa nethebula le-titration I-OxyCRG yokubuka eguquguqukayo isibonisi Ukuqapha ukuphefumula ngama-alamu we-apnea Ukubuyekezwa kwe-alamu, ukubuyekezwa kwe-arrhythmia Ulwazi lwesiguli.Idizayini ye-Anti-defibrillation yokufaka i-NIBP ngaphezu kokuvikelwa kwengcindezi Ibhethri le-plug-in eliphinda lishajwe, i-AC/DC iyatholakala.Izintambo ezisekelayo noma inethiwekhi engenantambo.
Imonitha yesiguli se-AM iyathengiswa I-AMMP06 Imininingwane Yobuchwepheshe
I-ECG Lead Mode 5 Leads (R, L, F, N, C noma RA, LA, LL, RL,V) Ukukhetha okuholayo I, II, III, avR, avL, avF, V Wavef orm 2 ch Imodi eholayo 3 Ukuhola ( R, L, F noma RA, LA, LL) Ukukhetha okuholayo I, II, III, Wave form 1 ch Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto HR kanye ne-Alarm Range Adult 15 ~ 300 bpm I-Neo/Ped 15 ~ 350 bpm Ukunemba ±1% noma ±1bpm, okuyi-Resolution enkulu 1 bpm Ukuzwela > 200 (uVp-p) Ukuphazamiseka Kokufaka Okuhlukile > 5 MΩ CMRR Monitor > 105 dB Operation 8B > Diagnod 8B I-dB Electrode engase ibe namandla ±300mV Ukuvuza Kwamanje < 10 uA Ukubuyiselwa Okuyisisekelo < 3 S Ngemva kwe-Defi.I-ECG Signal Range ±8 m V ( Vp-p ) Ukuhlinzwa Kwe-Bandwidth 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz Calibration Signal 1 (mVp-p), Ukunemba: 5% ST Segment Monitoring Range Range -20. ~ +2.0 mV ARR Uhlobo Lokuthola: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,I-alamu Iyatholakala,Buyekeza Indlela Yokuphefumula Etholakalayo RF(i-RA- LL) Umehluko Wokufaka Kokufaka > 2.5 MΩ Ibanga Lokulinganisa Lokulinganisa 0.3~3 Ω Ibanga eliyisisekelo lokungena Impedance 200~4 KΩ Umkhawulokudonsa 0.1~2.5Hz Resp.Isilinganiso Sokukala kanye Nebanga Le-alamu Umuntu Omdala 0 ~ 120 Brpm Neo/Ped 0 ~ 150 Brpm Ukulungiswa 1 Brpm Ukunemba ±2 Brpm I-Alarm ye-Apnea 10 ~ 40 SImanuwali yemodi ye-NIBP yeNdlela ye-Oscillometric, Okuzenzakalelayo, Isikhawu sokulinganisa se-STAT kumodi ye-AUTO engu-1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min) Isikhathi Sokulinganisa 5 I-Rate Rate Rate Range Range Range Range Radion 40 ~ 240 bpm Uhlobo Lwe-alamu SYS, DIA, MEAN Ukulinganisa nebanga le-alamu Imodi Yabantu Abadala SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Imodi Yezingane SYS 40 ~ 200 mmHg ~ 200 mmHg ~150 mmHg ~ 150 mmHg DIA ~15 151 mmHg MEAN 151 Imodi SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg Ukulungiswa 1mmHg Ukunemba Ubukhulu Iphutha Lencazelo ±5mmHg Ukuchezuka Okujwayelekile Okuphezulu ±8mmHg Ukuvikelwa Ngokudlulele Kokucindezela Imodi Yabantu Abadala 297±3 mmHg4 Mode 3 mmHg4 ± 3 mmHg4Hg4Hg2Hg2Hg Ne-3 mmHg2Hg2Hg Ukulinganisa u-Range 0 ~ 100 % I-Alarm Range 0 ~ 100 % Ukulungiswa 1 % Ukunemba 70% ~ 100% 2 % 0% ~ 69% okungacaciswanga I-intervalabout yokwenzekayo 1 Isekhondi.Ukubambezeleka kwe-alamu 10 Sec.I-Pulse Rate Measuring and Alarm Range 20~300 bpm Resolution 1bpm Ukunemba ±3bpm TEMP Channel 2 Measuring and Alarm Range0 ~ 50 ℃ Ukulungiswa 0.1 ℃ Ukunemba ±0.2 ℃ Actualization intervalabo.Isikhathi Esijwayelekile Esiqhubekayo < 10 Sec.Ilebula ye-IBP ART, PA, CVP, RAP, LAP, ICP, P1, P2 Ibanga lokulinganisa ne-alamu ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP-10 ~ 40 mmHg P1 / P2-10 ~ 300 mmHg Press Sensitivity 5 uV/V/mmHg Impedance 300-3000Ω Ukulungiswa 1 mmHg Ukunemba ±2% noma 1mmHg okuyisilinganiso esikhulu sokwenza umsebenzi mayelana nonobhala ongu-1Okujwayelekile: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature Optional: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder