Imininingwane Esheshayo
Ngokubukeka okuhlangene, futhi kulula ukuyisebenzisa
Ukupakisha Nokulethwa
Imininingwane yokupakisha:Iphakheji yokuthekelisa ejwayelekile Imininingwane yokulethwa: phakathi nezinsuku zokusebenza eziyi-7-10 ngemuva kokuthola inkokhelo |
Imininingwane
Umshini wezokwelapha we-c-arm x-ray fluoroscopy uyathengiswa AMCX30
Umshini wezokwelapha we-c-arm x-ray fluoroscopy AMCX30 Imininingwane
I-1.Fluoroscopic Capacity Max rated capacity : Ishubhu Yamanje 4mA, Tube Voltage 110kV Automatic Fluoroscopy : Tube Voltage:40kV~110kV Lungisa Okuzenzakalelayo Ishubhu Yamanje : 0.3mA~4mA Manually Settings Tube1Vous Manual ~ I-Continuous VlV0 Manual : I-Continuous Vl Vyuma I-mA~4mA Pulse Fluoroscopy : I-Continuous Tube Voltage 40kV~110kV Continuous Tube Yamanje 0.3mA~8mA 2. Umthamo Wezithombe Umthamo olinganiselwe wesilinganiso : 3.5 KW Tube Voltage kanye Nenhlanganisela Yamanje : 10kV1~ 40kV8 ~ 40kV5 ~ 40kV5 ~ 40kV 40kV 40kV 40kV5 ~ 69kv 1 ~ 125 Mas 70kv ~ 79kv 1 ~ 110 Mas 80kv ~ 89kv 1 ~ 83 Mas 90kv 1 ~ 60 Mas Plate Holder Usayizi (8 "× 10") noma 250mm ×300mm(10″×12″)3. Ishubhu ye-X-ray yeshubhu ye-X-ray Ekhethekile Ye-anode Egxilile Ye-anode Ekabili: ukugxila okukhulu: 1.5, ukugxila okuncane: 0.3mm*0.3mm (Inzuzo) I-Inverter Frequency : 40KHz Umthamo we-Thermal : 35KJ (47KHU) 4.Ividiyo I-System Image Intensifier : Isiqinisi Sesithombe esenziwe ngu-TOSHIBA (9″, 6″,4.5″) CCD Vidicon : Ikhamera ye-CCD enokukhanya okuphansi okuphezulu kakhulu engeniswe isuka e-Japan Monitor : Imigqa evundlile engu-1000 nemigqa eqondile engu-800, Umkhawulokudonsa : 12.5MHz, Isithombe/sese I-75 CCU(ukulawula okumaphakathi) : Isihlungi Esiphindaphindayo: K=8,8 isitoreji sezithombe, isithombe simile, ukuphenduka kwesithombe, isithombe esihle nesibi;LIH(Isithombe Sokugcina Ukubamba) kanye ne-OSD (isibonisi sokuqapha) 5.Isakhiwo: Isondo lokuqondisa : ±90 °revolution, ingashintsha ngokukhululekile isiqondiso seyunithi.Uhla Lwezinsika Olukhuphukayo Nolwehla : ≥400mm C-arm : Ukunyakaza Okuya Phambili Nasemuva: 200mm Revolution ezungeze i-Horizontal Axis: ±180° Revolution ezungeze i-Vertical Axis : ±15°( Advantage), engcono kunabanye' ±12.5°, kulula ukuyithatha i-radiography yezikhundla ezikhethekile ) Slip ku-orbit: 120°(+90°~ -30°)
Umshini we-c-arm x-ray fluoroscopy uyathengiswa Izici ze-AMCX30
1, Ngokubukeka okuhlangene, futhi kulula ukuyisebenzisa;2、Isistimu Yevidiyo Yomtholampilo esebenza kahle kakhulu, ivolumu yokugcina izithombe eziyi-8, kanye nemonitha eyodwa engu-14〞enokulungiswa okuphezulu, i-LCD Monitor eyodwa engu-19'';3, Landelela ngokuzenzakalelayo i-fluoroscopy ukuze wenze ukukhanya kwesithombe kube nokucaca okukhulu;4, Gcina ngokuzenzakalelayo isithombe sokugcina se-fluoroscopy ukuze uzuze ukuxilongwa;5, Ngomshini wokuphehla amandla we-X-ray wekhwalithi ephezulu ukuze kuncishiswe ukusetshenziswa kwami ngemisebe: Amathambo: i-osteopathy, i-diaplasis, Ukuhlinza izipikili: ukususa umzimba wangaphandle, i-catheter yenhliziyo, i-pace maker, ukwelashwa kokungenelela, i-radiography engaphelele, ukuthwebula izithombe kwasendaweni, nomunye umsebenzi. .II Izici 1、Ngokubukeka okuhlangene, futhi kulula ukuyisebenzisa 2、Idizayini yengalo yokusiza kagesi eyisisekelo esiyingqayizivele, kuwukuvikeleka okwengeziwe ekusebenziseni.3, Idizayini yesilawuli esiphethwe ngesandla esiyingqayizivele, esilungele ukusebenza 4, Ngejeneretha ye-X-ray yekhwalithi ephezulu yokunciphisa imisebe 5, Nge-Perspective KV, i-MA ilandelela ngokuzenzakalelayo i-fluoroscopy ukuze wenze ukukhanya kwesithombe nokucace kube kuhle 6, Toshiba isiqinisekisi sesithombe, ikhwalithi izinzile futhi inokwethenjelwa, ukucaca okuhle kwesithombe 7、Isistimu Yevidiyo Yomtholampilo esebenza kahle, ivolumu yezithombe eziyi-8, kanye nemonitha eyodwa engu-14〞 enesinqumo esiphezulu, i-LCD Monitor eyodwa engu-19''.8, Ukufakwa kwamagridi aminyene okusanhlamvu, ukuze kuthuthukiswe ukucija kwesithombe III Ukucushwa 1, Okusha (okunengalo yokusiza kagesi) Umsingathi we-C-arm isethi eyodwa engu-2, ijeneretha ye-X-ray enezinga eliphezulu kanye nogesi oguquguqukayo (3.5KW、40KHZ、110KV) isethi eyodwa 3, i-Toshiba 9-inch image intensifier isethi eyodwa 4, Ukungenisa kwekhamera yedijithali enokukhanya okuphansi kakhulu isethi eyodwa 5. I-CCU kusistimu yokulawula okukhiphayo enencazelo ephezulu isethi eyodwa 6,Iminyene amagridi okusanhlamvu isethi eyodwa 7,Ijubane likagesi elilungisekayo isethi eyodwa 8,14-intshi HD qapha ezokwelapha ezizimele isethi 9. 19'' LCD Gada isethi eyodwa 10, Ukusetshenziswa okukodwa isilawuli esiphathwa ngesandla isethi 11, Isiteshi somsebenzi Digital esinephrinta eshisayo isethi eyodwa
Isithombe sefekthri ye-AM, umphakeli wezokwelapha wokubambisana kwesikhathi eside.
Isithombe se-AM TEAM
Isitifiketi se-AM
I-AM Medical ibambisana ne-DHL, FEDEX, UPS, EMS, TNT, njll. Inkampani yokuthumela izimpahla yamazwe ngamazwe, yenza izimpahla zakho zifike lapho uya khona ngokuphepha nangokushesha.